Specifications
Video
Gain ............................................... Unity
Bandwidth
MDA 3SV/3SVA/3SV Dual 270 MHz (-3dB)
MDA 3V/3AV/3V Dual .... 435 MHz (-3dB)
Differential phase error .............. 0.05º, 0 to 50 MHz
Differential gain error ................. <0.05%, 0 to 50 MHz
K factor .......................................... <0.05%
Video input
Number/signal type
MDA 3SV/3SVA .............. 1 NTSC/PAL/SECAM S-video
MDA 3SV Dual ................ 2 NTSC/PAL/SECAM S-video
MDA 3V/3AV .................. 1 NTSC/PAL/SECAM composite video
MDA 3V Dual .................. 2 NTSC/PAL/SECAM composite video
Connectors
MDA 3SV/3SVA .............. 1 4-pin mini DIN female
MDA 3SV Dual ................ 2 4-pin mini DIN female
MDA 3V/3AV .................. 1 BNC female
MDA 3V Dual .................. 2 BNC female
Minimum/maximum level(s)
MDA 3SV/3SVA/3SV Dual Y: 0.4V to 2.0V p-p with no offset
MDA 3V/3AV/3V Dual .... 0.4V to 2.0V p-p with no offset
Impedance .................................... 75 ohms
Return loss .................................... -40dB @ 0 to 10 MHz
Maximum DC offset .................... 5.0V
Video output
Number/signal type
MDA 3SV/3SVA .............. 3 buffered S-video
MDA 3SV Dual ................ 2 x 3 buffered S-video
MDA 3V/3AV .................. 3 buffered composite video
MDA 3V Dual .................. 2 x 3 buffered composite video
Connectors
MDA 3SV/3SVA .............. 3 4-pin mini DIN
MDA 3SV Dual ................ 6 4-pin mini DIN
MDA 3V/3AV .................. 3 BNC female
MDA 3V Dual .................. 6 BNC female
VersaTools™ MDA 3 Series • Specifications
Power (all models)
CAUTION
Power supply voltage polarity is extremely
important. Applying power with incorrect voltage
polarity could damage the power supply and the
MDA. Identify the power cord negative lead by the
ridges on the side of the cord.
10
Power connector—
Plug the external 12VDC power supply into
this 2-pole captive screw connector. The power supply is
included with the unit. Figure 10 shows how to wire the
connector.
Return
+12VDC
End Captive
Screw
Connector
view of
power supply
output cord.
Figure 10 — Power connector wiring
Do not tin the stripped power supply leads before
installing the captive screw connector. Tinned wires are
not as secure in the captive screw connectors and could
be pulled out.
The two power cord wires must be kept separate
while the power supply is plugged in. Remove
power before wiring.
To verify the polarity before connection, plug in the power
supply with no load and check the output with a voltmeter.
Alternatively, an Extron P/S 100 Universal 12VDC Power
Supply can power up to ten MDAs or other Extron 12VDC
devices using only one AC power connector.
11
Power LED
(figure 11)
—
Indicates power is applied to the
MDA.
DISTRIBUTION AMPLIFIER
11
Front Panel, all MDA Models
Figure 11 — MDA 3 Series front panel (all models)
VersaTools™ MDA 3 Series • Specifications
9