Extron electronics UCS FT 901 Скачать руководство пользователя страница 4

 

4

UCS FT 901 and FR 902 • User Guide (Continued)

Cabling and Setup

Figure 4 shows connections for the UCS FT 901 and UCS FR 902.

POWER

12V   

HOST

USB-C

SS 5G

Tx

OUTPUT

Rx

1

2

4

POWER
12V

1.0A MAX

INPU

T

OUTPUTS

1

2

4

POWER
12V

1.0A MAX

INPU

T

O

UTPUT

S

POWER

12V   

DEVICES

INPUT

Tx

1

Rx

2

1.5 A

1.6A MAX

Ground

+12 VDC input

G

External Power Supply

(12 VDC, 2.0 A max.)

Ground all

Devices

Ground

+12 VDC input

G

External Power Supply

(12 VDC, 0.5 A max.)

Ground all

Devices

0.1A MAX

USB

USB Camera

Receiver

USB

Laptop

5

5

5

3

3

3

6

6

6

5

5

5

Transmitter

Multimode Fiber Optic Cable

Compatible with USB 3.2, 2.0, 1.1
peripheral devices

1

1

1

2

2

2

3

3

3

4

4

4

Compatible with USB 3.2
host ports ONLY

Figure 4. 

Transmitter and Receiver Connection with Two External Power Supplies

Installation Procedure

ATTENTION:

 

• 

Installation and service must be performed by authorized personnel only.

• 

L’installation et l’entretien doivent être effectués uniquement par un technicien qualifié.

To ensure proper operation, the transmitter, receiver, USB host, and USB peripherals must be connected properly and in the 
sequence described here (see figure 4). 

1. 

Power off all devices that will be directly connected to the receiver.

2. 

Wire each of the two provided power supplies to their 2-pole captive screw connectors (see figure 5).

Captive Screw Connector

Tie Wrap

Heat
Shrink

1/8"

(3 mm)

7/8"

(22 mm)

3/16"

(5 mm) Max.

Figure 5. 

Wiring the Power Connector for the UCS FT 901 and FR 902

NOTE:

  The UCS FT 901 (transmitter) can also be powered by the host device, without the need for the external power 

supply. 

3. 

Plug the two power supply connectors into their respective transmitter or receiver rear panel connectors (see figure 4, 

3

). 

Connect the 6 Watt power supply (

1

) to the transmitter, and the 24 Watt (

2

) to the receiver.

The green Power LED (see 

figure 6

A

, on the next page) on the front panel of each device lights when each device is 

powered on. 

4. 

Connect a USB Type A-to-C or Type C-to-C cable from the host device to the transmitter Host port (

4

). The Host LED 

(

figure 6

B

) will light, indicating that communication between the transmitter and host device has been established.

 

 

Содержание UCS FT 901

Страница 1: ...es regulatory compliances EMI EMF compatibility accessibility and related topics see the Extron Safety and Regulatory Compliance Guide on the Extron website Features Point to point transmission Extends USB peripherals up to 985 ft 300 meters over fiber optic cable for point to point applications Supports USB 3 2 2 0 and 1 1 devices Supports bulk control interrupt and isochronous transfers as defin...

Страница 2: ...reater than room ambient temperature Therefore install in an environment compatible with the maximum ambient temperature Tma 122 F 50 C specified by Extron 2 Reduced air flow Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised 3 Mechanical loading Mount the equipment in the rack so that a hazardous condition is not achieved...

Страница 3: ...imité de l équipement audiovisuel Extron dans un emplacement habituel avec un degré de pollution 2 fixée à une estrade un bureau ou dans une baie technique à l intérieur d un placard dédié Always use a power supply provided by or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product Utilisez touj...

Страница 4: ...To ensure proper operation the transmitter receiver USB host and USB peripherals must be connected properly and in the sequence described here see figure 4 1 Power off all devices that will be directly connected to the receiver 2 Wire each of the two provided power supplies to their 2 pole captive screw connectors see figure 5 Captive Screw Connector Tie Wrap Heat Shrink 1 8 3 mm 7 8 22 mm 3 16 5 ...

Страница 5: ...ognizes the transmitter and when the transmitter and receiver are connected with each other 8 Connect up to two USB peripheral devices such as a camera keyboard touchpanel or printer to the receiver USB ports figure 4 6 The system is now ready to operate Front Panel Features Transmitter UCS FT 901 UCS FT 901 e LINK HOST STATUS POWER 12V 0 1A MAX HOST USB C SS 5G Tx OUTPUT Rx A B C A B C Receiver U...

Страница 6: ...C also mount the ZipClip 100 adjacent to the ZipClip 200 Figure 8 Under desk Mounting ZipClip 100 and ZipClip 200 2 Mount the UCS transmitter or receiver to the ZipCaddy 200 If mounting the transmitter also mount its external power supply PS 1205 C as follows Align the mounting holes on the bottom of the UCS unit with the mounting holes on the ZipCaddy see figure 9 and fasten the screws NOTE The r...

Страница 7: ...e receiver power supply PS 1215 C can be attached and detached from the ZipClip 100 no ZipCaddy necessary Figure 10 Attaching and Releasing the UCS FT 901 UCS FR 902 and PS 1215 C E E E E E E E E E E E E UCS FT 901 e LINK HOST STATUS UCS FT 901 ZipClip 200 PS 1205 C E E E E E E E E E E E E e UCS FR 902 LINK STATUS ZipClip 200 ZipClip 100 PS 1215 C UCS FR 902 ...

Страница 8: ...et 1 8 meters When connecting the host or peripherals use only cables designed for USB signals Avoid or limit the use of adapters The UCS FT 901 and UCS FR 902 work as described in point to point applications Do not use additional adapters patch panels or couplers with USB cables or fiber optic cables Additional links in the signal chain can result in reduction of signal integrity and overall syst...

Отзывы: