Extron electronics UCS FT 901 Скачать руководство пользователя страница 1

1

UCS FT 901 and UCS FR 902 • User Guide

The UCS FT 901 and UCS FR 902 extend USB signals from USB 3.2, 2.0, and 
1.1 peripheral devices up to 985 ft (300 meters) to a USB 3.2 host computer over 
multimode fiber optic cable with super speed data transfer rate of up to 5 Gbps. 
The transmitter features a USB Type-C connector. The receiver features a  
built-in active two-port hub that supplies up to 5 V, 1.5 A each port, to power 
attached devices. 
The UCS FT 901 and UCS FR 902

 

are 1 inch (25 mm) high, 3 inches (76 mm) deep, one-eighth rack (transmitter) and quarter rack 

(reciever) wide. They can be mounted to a rack or under furniture, or placed on a tabletop.

NOTE:

 

• 

This product supports USB data ONLY. DisplayPort Alt Mode and Power Delivery are NOT supported.

• 

The use of USB 2.0 hub on the UCS FR 902 is not recommended. If a USB hub is needed, Extron recommends using a 
USB 3.2 hub. Please contact your Extron AE for more details.

FCC Class A Notice

This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the 
FCC rules. The Class A limits provide reasonable protection against harmful interference when the equipment is operated in a 
commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used 
in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment 
in a residential area is likely to cause interference. This interference must be corrected at the expense of the user.

NOTE:

  For more information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related 

topics, see the “

Extron Safety and Regulatory Compliance Guide

” on the Extron website.

Features

• 

Point-to-point transmission 

— Extends USB peripherals up to 985 ft (300 meters) over fiber optic cable for point-to-point 

applications.

• 

Supports USB 3.2, 2.0, and 1.1 devices 

— Supports bulk, control, interrupt, and isochronous transfers as defined by the 

USB specification. 

• 

Provides data transfer rates up to 5 Gbps

 — Allows for the use of USB 3.2 cameras and other USB conference room 

peripherals requiring high bandwidth support.

• 

Integrated dual-port devices

 — The receiver has two integrated USB ports, which provide up to 5 volts,1.5 amps on each 

port. Allows simultaneous connection to multiple peripheral devices such as USB cameras, docks, all-in-one conference 
systems, interactive displays, annotation devices, mass storage, keyboards, and mice in pro AV environments.

• 

Real-time status LED indicators for troubleshooting and monitoring

 — 

Front panel LED indicators provide visual 

confirmation of active host and link status.

• 

Rack and furniture mountable

 — 

Low-profile, 1-inch (2.5 cm) high, 3-inch deep (7.6 cm), eighth rack wide (UCS FT 901) 

and quarter rack wide (UCS FR 902) metal enclosures enable discreet installation, such as beneath a table or behind a 
display. One (1) ZipClip 100 and two (2) ZipClip 200 mounting accessories are included.

• 

VBUS powered transmitter 

— UCS FT 901 can be powered by host PC or included external power supply.

• 

External Extron Everlast power supply included

 — Provides worldwide power compatibility with high-demonstrated 

reliability and low power consumption.

• 

Extron Everlast Power Supply is covered by a 7-year parts and labor warranty 

Specifications

Product specifications are available on the Extron website, 

www.extron.com

.

Содержание UCS FT 901

Страница 1: ...es regulatory compliances EMI EMF compatibility accessibility and related topics see the Extron Safety and Regulatory Compliance Guide on the Extron website Features Point to point transmission Extends USB peripherals up to 985 ft 300 meters over fiber optic cable for point to point applications Supports USB 3 2 2 0 and 1 1 devices Supports bulk control interrupt and isochronous transfers as defin...

Страница 2: ...reater than room ambient temperature Therefore install in an environment compatible with the maximum ambient temperature Tma 122 F 50 C specified by Extron 2 Reduced air flow Install the equipment in a rack so that the amount of air flow required for safe operation of the equipment is not compromised 3 Mechanical loading Mount the equipment in the rack so that a hazardous condition is not achieved...

Страница 3: ...imité de l équipement audiovisuel Extron dans un emplacement habituel avec un degré de pollution 2 fixée à une estrade un bureau ou dans une baie technique à l intérieur d un placard dédié Always use a power supply provided by or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification and may cause damage to the supply and the end product Utilisez touj...

Страница 4: ...To ensure proper operation the transmitter receiver USB host and USB peripherals must be connected properly and in the sequence described here see figure 4 1 Power off all devices that will be directly connected to the receiver 2 Wire each of the two provided power supplies to their 2 pole captive screw connectors see figure 5 Captive Screw Connector Tie Wrap Heat Shrink 1 8 3 mm 7 8 22 mm 3 16 5 ...

Страница 5: ...ognizes the transmitter and when the transmitter and receiver are connected with each other 8 Connect up to two USB peripheral devices such as a camera keyboard touchpanel or printer to the receiver USB ports figure 4 6 The system is now ready to operate Front Panel Features Transmitter UCS FT 901 UCS FT 901 e LINK HOST STATUS POWER 12V 0 1A MAX HOST USB C SS 5G Tx OUTPUT Rx A B C A B C Receiver U...

Страница 6: ...C also mount the ZipClip 100 adjacent to the ZipClip 200 Figure 8 Under desk Mounting ZipClip 100 and ZipClip 200 2 Mount the UCS transmitter or receiver to the ZipCaddy 200 If mounting the transmitter also mount its external power supply PS 1205 C as follows Align the mounting holes on the bottom of the UCS unit with the mounting holes on the ZipCaddy see figure 9 and fasten the screws NOTE The r...

Страница 7: ...e receiver power supply PS 1215 C can be attached and detached from the ZipClip 100 no ZipCaddy necessary Figure 10 Attaching and Releasing the UCS FT 901 UCS FR 902 and PS 1215 C E E E E E E E E E E E E UCS FT 901 e LINK HOST STATUS UCS FT 901 ZipClip 200 PS 1205 C E E E E E E E E E E E E e UCS FR 902 LINK STATUS ZipClip 200 ZipClip 100 PS 1215 C UCS FR 902 ...

Страница 8: ...et 1 8 meters When connecting the host or peripherals use only cables designed for USB signals Avoid or limit the use of adapters The UCS FT 901 and UCS FR 902 work as described in point to point applications Do not use additional adapters patch panels or couplers with USB cables or fiber optic cables Additional links in the signal chain can result in reduction of signal integrity and overall syst...

Отзывы: