3-3
IN1502 • Serial Communication
Using the command/response tables
The command/response tables on the next page list valid command ASCII codes,
the scaler’s responses to the host, and a description of the command’s function
or the results of executing the command. Uppercase and lowercase characters
may be used interchangeably in the command field.
The ASCII to HEX conversion
table at left is for use with the
command/response tables.
ASCII to Hex conversion table
ASCII to HEX Conversion Table
•
The command/response tables use symbols (defined below) to represent variables.
Symbol definitions
=
CR/LF (carriage return/line feed) (hex 0D 0A)
•
=
Space
Esc
=
Escape key
X1
=
Specific input number (1 or 2)
1 = input 1
2 = input 2
X2
=
0 = off, 1 = on
X3
=
Picture adjustment range (0 through 255)
X4
=
Sharpness level (details) (0 through 63)
X5
=
Scaler resolution
1 = 640 x 480
2 = 800 x 600
3 = 848 x 480
4 = 852 x 480
5 = 1024 x 768
6 = 1280 x 768
7 = 1360 x 765
8 = 1366 x 768
X6
=
Detected input signal standard (0 through 4)
0 = none
1 = NTSC 3.58
2 = PAL
3 = NTSC 4.43
4 = SECAM
X7
=
Blanking adjustment range (0 through 127 lines)
X8
=
Scaler refresh rate
1 = 50 Hz
2 = 60 Hz
Содержание Two InpuT VIdeo Scaler IN1502
Страница 1: ...IN1502 Video Scaler 68 1205 01 Rev D 02 08...
Страница 4: ......
Страница 6: ...IN1502 Quick Start QS 2...
Страница 9: ...IN1502 1 Chapter One Introduction About this Manual About the IN1502 Features and Options...
Страница 12: ...Introduction cont d IN1502 Introduction 1 4...
Страница 28: ...Installation and Operation cont d IN1502 Installation and Operation 2 16...
Страница 29: ...IN1502 3 Chapter Three Serial Communication RS 232 Programmer s Guide...
Страница 36: ...Serial Communication cont d IN1502 Serial Communication 3 8...
Страница 37: ...IN1502 A Appendix Appendix Specifications Part Numbers and Accessories Firmware Upgrade Installation...