TLP Pro 525M, 725M, and 1025M Series • Setup Guide

Overview

The Extron TLP Pro 525M, TLP Pro 725M, and TLP Pro 1025M are three series of wall mounted capacitive touchscreen touchpanels 
with a TFT active matrix color LCD screens.

• 

The TLP Pro 525M series touchpanels have a 5-inch screen with a 800x480 resolution and 24-bit color depth.

• 

The TLP Pro 725M series touchpanels have a 7-inch screen with a 1024x600 resolution and 24-bit color depth.

• 

The TLP Pro 1025M series touchpanels have a 10.1-inch screen with a 1280x800 resolution and 24-bit color depth. 

They are ideal for any AV application requiring compact touchpanels with flexible mounting options and fully customizable interfaces. 
This guide provides instructions for experienced installers to mount and install these touchpanels.

Setup Checklist

Get Ready

 

…

Download and install the latest version of the following software:

 

…

GUI Designer

 — For designing layouts for Extron TouchLink

®

 Pro touchpanels and third party touch interfaces. 

 

…

Global Configurator

®

 Professional and Global Configurator Plus

 — For setting up and configuring the control processor 

and touchpanel.

 

…

Toolbelt

 — Provides device discovery, device information, firmware updates, and configuration of network settings, system 

utilities, and user management for TouchLink Pro devices.

 

…

Global Scripter

®

 — Provides an integrated development environment for Extron control systems programming.

NOTE: 

All four software programs are available from 

www.extron.com

.

 

…

Obtain the following network information from your network administrator:

 

…

DHCP status

 — (on or off). If DHCP is off, you must also obtain:

 

…

IP address 

 

…

Subnet mask

 

…

Gateway

 

…

User name

 — This can be either 

admin

 or 

user

.

 

…

Password

  — By default, this is 

extron

 (for either admin or user).

 

…

Make a note of the touchpanel MAC address.

Mount and Cable All Devices

ATTENTION:

• 

Do not power on the touchpanels or control processors until you have read the Attention in the “Rear Panel Features” 
section of the 

TLP Pro 525, 725, and 1025 Series User Guide

 or the 

IPCP Pro User Guide or IPL Pro User Guide

.

• 

Ne branchez pas les écrans tactiles ou les contrôleurs avant d’avoir lu la mise en garde dans la section « Rear Panel 
Features » du 

TLP Pro 525, 725, and 1025 Series User Guide

 ou du 

IPCP Pro User Guide or IPL Pro User Guide

 

…

Mount the units. There are several mounting options for TouchLink Pro touchpanels (see 

Mounting

 on the next page). 

 

…

Connect the touchpanel to a Power over Ethernet injector (see 

figure 5

 on page 5).

 

…

Connect the power injector to the LAN and power it on (see 

figure 5

).

Set up the Touchpanels for Network Communication

 

…

Connect the PC that you are using for setup, the control processor, and the touchpanel 

to the same Ethernet subnetwork

.

 

…

Use the 

Setup Menu

 (see page 6) or Toolbelt to set the DHCP status and, if necessary, the IP address, subnet mask, gateway, 

and related settings for the touchpanel.

Configure the Touchpanels

The 

GUI Designer Help File

, the 

Global Configurator Help File

, and the 

Toolbelt Help File

 provide step-by-step instructions and 

detailed information. The 

Global Configurator Help File

 includes an introduction to the software and sections on how to start a project 

and configuration.
Global Scripter provides an Extron-exclusive Python library (ControlScript

®

) and Global Scripter modules to get you started.

Содержание TLP Pro 525M seriesl

Страница 1: ... DHCP status on or off If DHCP is off you must also obtain IP address Subnet mask Gateway User name This can be either admin or user Password By default this is extron for either admin or user Make a note of the touchpanel MAC address Mount and Cable All Devices ATTENTION Do not power on the touchpanels or control processors until you have read the Attention in the Rear Panel Features section of t...

Страница 2: ...he TLP Pro 725M and 1025M touchpanels mount to a 2 gang junction box Extron provides four 3 4 6 32 Philips pan head screws for mounting to US junction boxes Extron provides two 16 mm M 3 5 Philips pan head screws for mounting to MK junction boxes EU junction boxes are usually provided with their own screws With a wall box 1 Install a junction box or wall box see figure 1 1 following the instructio...

Страница 3: ...TLP Pro 725M The front panels of all the touchpanels have the same features and are almost identical apart from the size A A B B C C A A D D E E E E Figure 3 TLP Pro 725M Front Panel A Motion sensor Detects motion between three to five feet from the touchpanel and at least 15 from the center axis When no motion has been detected for a user defined period of time the touchpanel enters sleep mode Wh...

Страница 4: ...D D D D K K D D D D I I J J TLP Pro 1025M Figure 4 TLP Pro 525M 725M and 1025M Rear Panels NOTE The panels shown in figure 4 are for illustration only and are not to the same scale For more information follow these links to the next page A Menu Button B Reset Button C Reset LED D Mounting Slots E Digital Input Monitoring Port F LAN PoE Connector G USB Port H Speaker I Slot for Mounting Plate J Mou...

Страница 5: ...025 Series User Guide Le TLP Pro 525M le TLP Pro 725M et le TLP Pro 1025M supportent l alimentation via Ethernet PoE 802 3af classe 3 Veuillez lire la partie Attention dans la section Rear Panel Features du TLP Pro 525 725 and 1025 Series User Guide avant de mettre sous tension les écrans tactiles NOTE These touchpanels are shipped without a power injector The power injector must be purchased sepa...

Страница 6: ...efaults Press and hold the Reset button for 9 seconds After the Reset LED flashes three times release and momentarily press the Reset button Use this mode to return the touchpanel to factory default settings Status Display Audio Advanced Exit Network Info Model TLP Pro 725M Part Number 60 1563 02 Firmware Version 1 02 0001 b001 Network IP Address DHCP Host Name Off 192 168 254 251 TLP AB CD EF Dis...

Отзывы: