TLP Pro 300M Series • Setup Guide (Continued)

Reset Modes: a Brief Summary

The TLP Pro 300M Series touchpanels offer the following reset modes:

• 

Use Factory Firmware:

Use this mode with Toolbelt software to replace firmware in the event of conflicts arising from 
uploading a firmware update.
Press and hold the 

Reset

 button (see 

figure 4

C

) while applying power to the unit.

• 

Reset All IP Settings:

Use this mode to reset all network settings without affecting user-loaded files.
Press and hold the 

Reset

 button until the 

Reset

 LED (

B

) blinks twice (about 6 seconds). Release 

and momentarily press the 

Reset

 button again. 

• 

Reset to Factory Defaults:

Use this mode to return the touchpanel to factory default settings, including passwords.
Press and hold the 

Reset

 button until the 

Reset

 LED blinks three times (about 9 seconds). Release 

and momentarily press the 

Reset

 button again. 

NOTES:

• 

The factory configured passwords for all accounts on this device have been set to 
the device serial number. Passwords are case sensitive.

• 

If the device is reset to default settings, the password will be the default password 
configuration. The default password is 

extron

.

• 

Enable or Disable the 
DHCP Client:

Use this mode to toggle between DHCP enabled and DHCP disabled.
Press the 

Reset

 button five times, consecutively. After the fifth press, do not press the button again 

within 3 seconds. If DHCP was enabled, it is now disabled and the 

Reset

 LED blinks three times. If 

DHCP was disabled, it is now enabled and the 

Reset

 LED blinks six times.

Setup Menu

Figure 6 shows the 

Setup

 menu 

Status

 screen for the TLP Pro 300M.

Press the 

Menu

 button (see 

figure 4

D

) to open the 

Setup

 menu. Any of the six available 

screens (

Status

Network

Display

Audio

Project

 

Information

, and 

Advanced

) can be 

accessed by pressing the menu button in the top left corner of the screen (for more information, 
see the 

TLP Pro 300M Series User Guide

).

It may be necessary to scroll down to see all the information on the page (for example, see the 

Status

 screen in figure 6).

STATUS

EXIT

Device Information

Model

Part Number

Firmware

Bootloader

Network

TLP Pro 300M

60-1667-02

1.00.0001-003

1.00.0002

IP Address

192.168.254.251

Figure 6. 

Setup Menu: Status Screen for TLP Pro 300M

Connecting the Power Injector

The power injector must be purchased separately. Figure 5 shows the 
Extron XTP PI 100. Your power injector may look different. 
Connect a straight-through Ethernet cable from the power injector to a 
switch or router (

1

). This cable carries network information from the 

switch or router to the power supply input. A second straight-through 
cable (

2

) carries the network information and 48 VDC from the power 

injector to the touchpanel LAN/PoE connector (see 

figure 4

G

, on the 

previous page). Connect the IEC power cord to a convenient 100 VAC to 
240 VAC, 50-60 Hz power source (see figure 5, 

3

).

100-240V 

~

 50-60Hz

0.4A MAX

XTP

PWR

XTP PWR

To network switch

To touchpanel

1

1

1

2

2

2

3

3

3

Figure 5. 

Connecting to a Power Injector

 

4

68-3146-50 Rev. A

02 20

For information on safety guidelines, regulatory compliances, EMI/EMF compatibility, accessibility, and related topics, see the 

Extron Safety and Regulatory Compliance Guide

 on the Extron website.

For information about replacing and disposing of batteries, see the 

TLP Pro 300M Series User Guide

 at 

www.extron.com

.

 © 2020 Extron Electronics — All rights reserved.  