Troubleshooting
The sections below shows some common operating
problems and their solutions.
All models
Problem —
Pressing an input selection button does not
change the input.
Solution —
Verify the operating mode. The input
selection buttons do not change the input if the
switcher is in auto-switch mode or (for
SW AR MX, SW AR MX HV, and
SW 6 Component switchers only) auto-sequence
mode.
Problem —
Auto-switch does not work under composite
video, S-video, component video, or RGsB format.
Solution —
The sync portion of these video formats
must be connected to a video input and to the
H/S input through a T connector. See page 2-10.
SW AR MX, SW AR MX HV, and
SW 6 Component models
Problem —
You pressed input selection button 1, but the
input did not change, and one of the input/mode
selection LEDs is blinking (SW AR MX,
SW AR MX HV, and SW 6 Component switchers
only).
Solution —
Holding input selection button 1 for too
long causes the button to act as the front panel
mode selection button. To select an input, do not
hold the button after pressing it.
Problem —
The switcher is plugged into a functioning
power source, but does not turn on.
Solution —
Replace the fuse. See page 4-11.