2
SME 211 • Setup Guide (Continued)
Input Connections
C
HDMI input
– Connect an HDMI (or DVI with a suitable adapter) source device to input.
D
Analog audio input
– Connect a balanced or unbalanced stereo line level audio device to this 5-pole 3.5 mm captive screw
connector. Wire the connector as shown in figure 2.
Do not tin
the wires!
Unbalanced Stereo Input
Balanced Stereo Input
Tip
Ring
Tip
Ring
Sleeves
Tip
Sleeve
Sleeve
Tip
LR
LR
Figure 2.
Audio Input Captive Screw Connector Wiring
ATTENTION:
•
The length of the exposed wires in the stripping process is critical. The ideal length is 3/16 inch (5 mm). If longer,
the exposed wires may touch, causing a short circuit between them. If shorter, the wires can be easily pulled out
even if tightly fastened by the captive screws.
•
La longueur des câbles exposés est primordiale lorsque l’on entreprend de les dénuder. La longueur idéale est de
5 mm (3/16 inches). S’ils sont un peu plus longs, les câbles exposés pourraient se toucher et provoquer un court
circuit. S’ils sont un peu plus courts, ils pourraient sortir, même s’ils sont attachés par les vis captives.
•
Do not tin the wire leads before installing into the connector. Tinned wires are not as secure in the connector and
could be pulled out.
•
Ne pas étamer les conducteurs avant de les insérer dans le connecteur. Les câbles étamés ne sont pas aussi bien
fixés dans le connecteur et pourraient être tirés.
Output Connections
E
HDMI preview output
– Connect an HDMI (or DVI with a suitable adapter) display device to this HDMI output connector for
easy size and position setup and to access the internal web browser.
Front Panel Features
SME 211
STREAMING MEDIA PROCESSOR
INPUT
OUT
HDCP
HDMI
HDMI LINE HDMI
CLIP
AUDIO
CONFIG
USB
ALARM
MASK
F
E
H
A
C
B
D
G
Figure 3.
SME 211 Front Panel
A
Power LED
—
•
Green
—
The power is on and the unit is operational.
•
Blinking Green
—
The power is on but the unit is still booting (not operational).
B
Alarm LED
—
Lights red steadily when one or more alarms are triggered.
C
Config port
—
Connect a control device to this port with a USB Mini-B cable (not supplied). Use this port to send SIS
commands to the SME 211 for device configuration and control.
NOTE:
For information on using this port for device configuration and control and for a list of available SIS commands,
see the
SME 211 User Guide
.