background image

1

SME 211 • Setup Guide

The Extron SME 211 is a high performance H.264 streaming media encoder for streaming audio and video signals over IP 
networks. It accepts an HDMI signal with embedded audio and an analog audio signal. The SME 211 supports unicast and 
multicast streaming protocols, including RTMP. The SME 211 can stream at two different resolutions and bit rates concurrently, 
supporting up to six simultaneous streams with push and pull streaming. Built-in audio mixing and DSP features enable enhanced 
audio processing without requiring external mixing and DSP equipment.

Mounting the SME 211

The SME 211 is housed in a 1U high, half rack width metal enclosure that can sit on a table with the provided rubber feet or 
can be mounted in a rack or under table. Select a suitable mounting location, then choose an appropriate mounting option. 
Before connecting the SME 211, turn off all devices that will be connected and then make all external device connections to the 
SME 211 before applying power to the devices.

Rear Panel Overview

Rx

Tx

G

RS-232

RESET

INPUTS

OUTPUT

REMOTE

SME 211

100-240V     0.7A

50-60 Hz

LAN

USB

HDMI

HDMI

L

AUDIO

LINE

R

C

D

E

F

B

H

G

A

Figure 1. 

SME 211 Rear Panel

A

  100-240 VAC IEC connector for power input

E

  HDMI preview output

B

  USB type A receptacle for external storage device or 

mouse and keyboard for network setup

F

  3.5 mm, 3-pole captive screw connector for Simple 

Instruction Set (SIS™) control over RS-232

C

  HDMI input

G

  Reset button and LED

D

  3.5 mm, 5-pole captive screw connector for analog 

stereo audio input

H

  RJ-45 Ethernet connector for LAN connection

Power Connection

A

 

100-240 VAC power input

 – Connect the provided IEC cord. Verify the front panel buttons and LCD illuminate (see 

Front 

Panel Features

 on page 2).

Control System and External Device Connections

The SME 211 can be configured and controlled from the front panel USB Mini-B Config port (see 

figure 4

D

 on page 2) using 

SIS commands and DataViewer via telnet port 23, or from the LAN port using a standard web browser. Because the LAN port 
must be connected for streaming output, Extron recommends using it for configuration, remote control, and firmware upgrades.

B

 

USB receptacle 

– Attach an external USB storage device to load mask images or other files to the user file system. 

A mouse and keyboard can also be attached to this receptacle for network setup.

F

 

Remote 

— To control the SME 211 using SIS commands over RS-232, connect the host RS-232 cable to the rear panel 

(see the illustration at right) with a 3-pole captive screw connector for bidirectional (±5 V) serial host control. The default 
protocol for this port is 

9600 baud

no parity

8 data bits

1 stop bit

, and 

no flow control (handshaking)

.

G

 

Reset button and LED 

— The SME 211 has several reset modes to return user-defined configuration settings or all 

settings back to factory defaults. The LED blinks to indicate the desired reset mode, and provides the reset status during 
the reset operation. For information on selecting the reset mode, see the 

SME 211 User Guide

.

H

 

RJ-45 Ethernet connector (LAN) 

— Use a standard Ethernet cable to connect to a network. The table at right has the 

default network settings. 

NOTE:

  To connect the SME 211 directly to a computer Ethernet port, use a 

crossover Ethernet cable.

Ground

Receiv

e

Tr

ansmit

Tx Rx

RS-232

G

REMOTE

IP Address:  192.168.254.254

Subnet Mask:  255.255.0.0

Default  Gateway:   0.0.0.0

DHCP:  OFF