background image

PA 300 Peaking Amplifi er • Installation and Operation

Installation and Operation

PA 300 Peaking Amplifi er • Installation and Operation

 

2-2

2-3

Tabletop use

Four self-adhesive rubber feet are included with the PA 300.
For tabletop use, affi x one foot at each corner of the bottom side 
of the unit and place the unit in the desired location.

Rack mounting

For optional rack mounting, do not install the rubber feet.  
Mount the PA 300 on a half-rack width, 6" deep, 1U high rack 
shelf (Extron part #60-190-10 or 60-604-10) or a standard 19-inch 
wide 1U rack shelf (part #60-190-01 or 60-604-01).

1.

 

Remove the rubber feet if they were previously installed 
on the bottom of the unit.

2.

 

Mount the unit on the rack shelf, using two 4-40  x  3/16" 
screws in opposite (diagonal) corners to secure it.

3.

 

Install blank panel(s) or other unit(s) on the rack shelf.

4.

 

Attach the rack shelf to the rack using the supplied bolts.

 

6" Deep Rack Shelf

Front false
faceplate
uses 2
screws.

1/2 Rack Width Front False
Faceplate 

Use 2 mounting holes on
opposite corners.

(2) 4-40 x 3/16"
Screws

Mounting the PA 300 on a 6-inch deep rack shelf

Installation Overview

1

  Make sure that the source device, the PA 300, and the 

output device are turned off and disconnected from the 
power source.

2

   If desired, mount the PA 300 in a rack or furniture.  See 

Mounting the PA 300

 below.

3

   Cable the inputs and outputs to the PA 300.  See 

Cabling

 on 

page 2-7.

4

  Plug the input device, the PA 300, and the output device 

into a grounded AC source.

5

  Turn on the input and output devices.

Mounting the PA 300

The PA 300 peaking amplifi er can be set on a table; mounted on 
a rack shelf; or mounted through or under a desk, podium, or 
tabletop.  

The following kits are available for mounting the PA 300:

 

• 

RSB 129 1U, 9.5" deep basic rack shelf 

 

(Extron part #60-604-01)

 

• 

RSU 129 1U, 9.5" deep universal rack shelf kit 

 (part 

#60-190-01) 

 

• 

RSB 126 1U, 6" deep basic rack shelf 

 (part 

#60-604-10)

 

• 

RSU 126 1U, 6" deep universal rack shelf kit 

 (part 

#60-190-10)

  MBU 125 Under-desk mounting kit   

 

 (part 

#70-077-01)

  MBD 129 Thru-desk mounting kit   

 

 (part 

#70-077-02)

The following sections provide instructions for these options.

im Vertrieb von

            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Содержание PA 300

Страница 1: ...Fax 31 33 453 4050 Extron Electronics Asia 135 Joo Seng Road 04 01 PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Kyodo Building 16 Ichibancho Chiyoda k...

Страница 2: ...fiziertem Servicepersonal durchgef hrt werden Die internen Komponenten des Ger tes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Ger t selbst ffnen da...

Страница 3: ...im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de...

Страница 4: ...letop use 2 3 Rack mounting 2 3 Under desk mounting 2 4 Through desk mounting 2 5 Front Panel Features 2 6 Rear Panel Features 2 6 Cabling 2 7 Chapter Three Adjusting the Display 3 1 Signal Compatibil...

Страница 5: ...Table of Contents Table of Contents cont d PA 300 1 Chapter One Introduction About this Manual About the PA 300 Features im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131...

Страница 6: ...ntiometers on the front panel On the rear panel the PA 300 provides five BNCs for RGBHV output and five BNCs for RGBHV input The unit restores the sync signals but does not process them for format pol...

Страница 7: ...opposite corners 2 4 40 x 3 16 Screws Mounting the PA 300 on a 6 inch deep rack shelf Installation Overview 1 Make sure that the source device the PA 300 and the output device are turned off and disco...

Страница 8: ...e desk or table at the locations of the mounting bracket screws The holes should be drilled from the underside or inside concealed side of the furniture where the amplifier will be located Through des...

Страница 9: ...the output device Cabling The PA 300 is specifically designed for long cable run applications For best results install the amplifier close to the signal source and drive a long cable to the display Th...

Страница 10: ...s LAN 1 2 3 4 5 6 7 8 1 2 3 4 INP UTS RES ET H SYNC V SYNC OUT PUT S R G B H V R G B H V Projector PC Up to 600 MHR or 1000 RG6 cable 1600 x 1200 signal 0 35 A 100 240V 50 6 0Hz OU TP UT 2 4 INP UT Ex...

Страница 11: ...ur source and attach a VTG 300 to this cable 2 Use the White Field test pattern for the VTG 300 setting 3 Remove the far end of the cable from your projector and attach the oscilloscope using 75 ohm t...

Страница 12: ...appear sharp When the HF is over adjusted ghosting may appear as illustrated below When the HF is under adjusted smearing may appear as shown below The potentiometer should be adjusted between these...

Страница 13: ...c Input type RGBHV RGBS RGsB RsGsBs Output type RGBHV RGBS RGsB RsGsBs Input level RGBHV RGBS TTL 1 8 V to 5 0 Vp p RGsB RsGsBs Analog 0 3 Vp p Output level RGBHV RGBS TTL 5 0 Vp p unterminated RGsB R...

Страница 14: ...versal Rack Shelf Kit 60 190 01 RSB 126 1U 6 Deep Basic Rack Shelf 60 604 10 RSU 126 1U 6 Deep Universal Rack Shelf Kit 60 190 10 MBU 125 Under Desk Mounting Kit 70 077 01 MBD 129 Through Desk Mountin...

Отзывы: