Figure 14. 

NBP 1200C Front Panel

A

 

Function buttons

 — Configure these buttons to light and function as desired.

B

 

Power buttons

 — These buttons (labelled “On” and “Off”) are usually used to control the power to the display device. The 

On

 

button has a nub that can be felt with fingertips.

C

 

Communications LED

 — This LED indicates the configuration and connection status of the NBP.

• 

Unlit — Normal operation (the NBP is configured and connected to an IPCP Pro control processor).

• 

Blinking red — The NBP has been configured but is not connected to an IPCP Pro control processor.

• 

Lit steadily — The NBP has not been configured.

D

 

Volume buttons

 — Configure 

Volume

 buttons to increment or decrement audio volume.

E

 

Volume LEDs

 — Volume LEDs light to act as a meter to indicate the volume level.

NOTE:

  There is no item 

F

 for this NBP model.

G

 

Cable Cubby lid

 — The lid tilts back to 130°. Friction washers ensure the lid holds any angle set by the user. A switch in 

the hinge activates the buttons when the lid is fully open and deactivates them when the lid is closed to prevent accidental 
button presses.

H

 

Button panel removal slots

 — Use the Extron removal tool in these slots to release the top of the panel when replacing buttons.

I

 

Button panel hinge

 — Holds the bottom of the panel in place, allowing the panel to tilt forward when replacing buttons.

All the function, power, and volume buttons must be configured or programmed to carry out their functions. The buttons are 
backlit by LEDs.
In addition to the visible features, the NBP has a buzzer located on a circuit board within the front panel. The behavior of the 
buzzer can be configured using Global Configurator or programmed with Global Scripter to be globally disabled or to beep as 
desired when a button is pressed. 

Содержание NBP 1200C

Страница 1: ...NBP 1200C and Other Devices in the System Step 10 Set up the NBP for Network Communication Step 11 Configure the System Step 12 Test and Troubleshoot Step 1 Get Ready Preparation checklist Use the fol...

Страница 2: ...ingle connectivity bracket is provided It can be used with either the AAP frame plate or the cable grommet plate Step 2 Prepare the Installation Site Cut the Table or Furniture ATTENTION Installation...

Страница 3: ...r acc der au connecteurs est soulign voir CNC Wood Router ci dessous Extron ne sera pas responsable des erreurs de coupe Ensure the table surface is at least 0 50 inch 1 27 cm thick Assurez vous que l...

Страница 4: ...e accommodates up to three single space AAPs Assembly procedures are shown in figure 2 at right Cable pass through module The cable pass through module accommodates up to eight AV cables Assemble the...

Страница 5: ...cable pass through module and power module Insert the modules into the cable cubby as shown in figure 5 NOTES Extron recommends mounting the power module on the left side of the enclosure For any cabl...

Страница 6: ...rd The panel is attached to the lid with a hinge that allows access to the buttons without the panel becoming completely detatched You can now return the lid to the fully open position 5 5 From the fr...

Страница 7: ...st the enclosure Lower the Cable Cubby into the hole to test the fit If necessary carefully enlarge the opening plastic m on f the e e ON OFF PC LA PTO P MUTE MED IA PL AY ER HDMI 1 HDMI 2 2 1 3 Figur...

Страница 8: ...2 3 1 4 Figure 9 Installing Retractors Step 8 Install Cables in the Cable Cubby e ON OFF PC LAPTOP MUTE MED IA PL AY ER HDMI 1 HDMI 2 For cable pass through applications allow at least 36 inches 0 9...

Страница 9: ...plex level autodetected Data rates 10 100Base T Power over Ethernet PoE The NBP receives power at this port Default login credentials Username admin Initial password unit serial number Password after...

Страница 10: ...for the control device NOTE See the Toolbelt Help File Global Configurator Help File and Global Scripter Help File as needed for step by step instructions and detailed information The help file for GC...

Страница 11: ...Volume LEDs Volume LEDs light to act as a meter to indicate the volume level NOTE There is no item F for this NBP model G Cable Cubby lid The lid tilts back to 130 Friction washers ensure the lid hold...

Страница 12: ...ettings to factory default values without affecting user loaded files Reset to Factory Defaults Press and hold the Reset button for 9 seconds After the Reset LED blinks three times release and momenta...

Страница 13: ...13 This page is intentionally left blank...

Страница 14: ...st the system make adjustments finalize configuration Save the project Cable the NBPs and the control processor or HCR receiver then apply power Cable all devices Prepare the installation site Get rea...

Отзывы: