Installation, cont’d
MTPX Plus Twisted Pair Matrix Switchers • Installation
2-4
Signal inputs
a
Inputs (TP) connectors —
Connect the TP outputs of compatible MTP or VTT
transmitters to these RJ-45 female connectors.
C
Do not connect this device to a computer data or telecommunications
network.
N
• You must configure the switcher for the appropriate content on the audio/
RS-232 wire pair (pins 3 and 6) for each TP input. See “Defining the
audio/RS-232 wire pair“ in chapter 3, “Operation”. You can also use SIS
commands (chapter 4,
Programmer’s Guide”) or the Windows-based control
program (chapter 5, “Matrix Software“).
• For best results, use a combined cable length of at least 50' (15 m) between
the transmitter and the receiver on the MTPX output.
• RJ-45 termination with CAT 5, CAT 5e, or CAT 6 cable must comply with
the TIA/EIA T568A or TIA/EIA T568B wiring standards for all connections.
RJ-45 termination with Enhanced Skew-Free A/V UTP cable must comply
with TIA/EIA T568A only.
• For low resolution MTPs (S-video and composite video) on the TP inputs, the
MTPX Plus audio circuits are compatible only with the newer generation,
mono audio models. See your MTP transmitter/ receiver and refer to the
associated manual to determine which MTP models you have.
Figure 2-4 shows the recommended termination of TP cables in accordance
with the TIA/EIA T568A or TIA/EIA T568B wiring standards. You can use
either standard with CAT 5, 5e, or 6 cable, but use the same standard on both
ends of the cable.
5
Pin
1
Red+/V. sync+
2
Red–/V. sync–
3
RS-232+
Green-
6
RS-232-
Mono audio+
Mono audio-
7
Blue+/H. sync+
8
Blue-/H. sync-
4
Wire color
White-green
NOTE
If you are using Enhanced Skew-Free™ A/V cable, use the TIA/EIA T568A standard only.
Green
White-orange
White-blue
Orange
White-brown
Brown
Wire color
T568A
T568B
Video input (via transmitter or local input)
Secondary input
RGB
White-orange
Orange
White-green
White-blue
Green
White-brown
Brown
Side
Green+
Blue
Blue
1 2 3 4 5 6 7 8
Insert
Twisted
Pair Wires
Pins:
RJ-45
Connector
Reserved
Reserved
Video-
Reserved
Reserved
Reserved
Reserved
Composite
Chroma (C)+
Chroma (C)-
Luma (Y)+
Luma (Y)-
S-video
Video+
Stereo audio
RS-232
Figure 2-4 — TP cable termination
N
Enhanced Skew-free A/V cable is not recommended for Ethernet/LAN
applications. This cable is specially designed for compatibility with Extron’s
Twisted Pair products that are wired using the TIA/EIA 568 A standard.
The green, brown, and blue pairs of this cable have virtually identical lengths
and should be used to transmit the RGB signals.
The orange pair of this cable has a different length and
should not
be used to
transmit the RGB signals.
Содержание MTPX Plus Series
Страница 1: ...MTPX Plus Series Mini Twisted Pair Matrix Switcher 68 1383 01 Rev B 09 08 ...
Страница 4: ......
Страница 20: ...Introduction cont d MTPX Plus Twisted Pair Matrix Switchers Introduction 1 10 ...
Страница 32: ...Installation cont d MTPX Plus Twisted Pair Matrix Switchers Installation 2 12 ...
Страница 92: ...Operation cont d MTPX Plus Twisted Pair Matrix Switchers Operation 3 60 ...
Страница 94: ...Operation cont d MTPX Plus Twisted Pair Matrix Switchers Operation 3 62 ...
Страница 171: ...MTPX Plus Twisted Pair Matrix Switchers A Appendix A Ethernet Connection Ethernet Link Subnetting A Primer ...
Страница 178: ...Ethernet Connection cont d MTPX Plus Twisted Pair Matrix Switchers Ethernet Connection A 8 ...
Страница 187: ...B 9 MTPX Plus Twisted Pair Matrix Switchers Reference Information Button label blanks 16 button strips ...
Страница 188: ...Reference Information cont d MTPX Plus Twisted Pair Matrix Switchers Reference Information B 10 ...