HTML Operation, cont’d
MPX 866 A Media Presentation Matrix Switcher • HTML Operation
6-4
PRELIMINAR
Y
System Confi guration Page
The matrix switcher downloads the System Confi guration page (fi gure 6-3) when
you click the
Confi guration
tab. The screen consists of fi elds in which you can
view and edit IP administration and system settings. The Passwords page can be
accessed by clicking the appropriate link. See appendix A,
Ethernet Connection
, for
basic information about IP addresses and subnetting.
Select Passwords
Video Input Settings
Refresh
Select Firmware Upgrade
Figure 6-3
—
System Confi guration page
On password-protected connections, there are two levels of protection:
administrator and user. Administrators have full access to all switching capabilities
and editing functions. Users can create ties, create and recall presets, set RGB and
audio mutes, and view all settings with the exception of passwords.
•
Ethernet connection to the switcher, either entering SIS commands (see
chapter 4,
SIS Programming and Control
) or using the Extron Matrix S
Control Program
(see chapter 5,
Matrix Software
)
is
password protected.
•
Connection via the RS-232 ports
is not
password protected.
IP Settings fi elds
The IP Settings fi elds provide a location for viewing and editing settings unique
to the Ethernet interface. After editing any of the settings on this page, click the
Submit
button at the bottom of the page.
Unit Name fi eld
The Unit Name fi eld contains the name used as the “from” information when the
switcher e-mails notifi cation of its failed or repaired status. This name fi eld can be
changed to any valid name, up to 24 alphanumeric characters.
N
The following characters are invalid in the matrix name:
+ ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.