Extron electronics MLS 306 Скачать руководство пользователя страница 46

MediaLink Switchers • Labeling

B-2

Labeling

Labeling Buttons on the Switcher

The MLS switchers have translucent panels (“windows”) behind which customized
labels can be inserted.  To remove a panel,

1.

Insert the head of a small Phillips screwdriver into the hole in one end of the
panel.

2.

Gently slide the tab on the edge of the panel out of the recess in the MLS’s
faceplate.

Premade templates and blank templates for the MLSs’ label windows are printed in
this chapter.  However, you can easily create, customize, and print labels by using
the Button-Label Generator software or any Brother P-Touch labeler.

Button-Label Generator Software

The Extron Button-Label Generator program (Buttons.exe) is shipped with the MLS
switchers, and it is also available on the Extron Web site.  This program is used to
create and print labels that can be placed in slot above the input selection buttons
on the MLSs.

The program occupies approximately 0.5 MB of disk space.  It can be run on a
diskette from a floppy drive, but it is more convenient to load and run the program
from a hard drive.

Installing the software

This program is installed at the same time and from the same diskettes as the
MediaLink control program.  See chapter four for details.  The Button-Label
Generator program can be installed separately via the Download page of the Extron
Web site (http://www.extron.com).  Follow the on-screen directions if you install
the program from the Web site.

By default, the Windows installation creates a C:\BUTTONS directory, and it will
place an icon (Button-Label Generator) into a group or folder named “Extron
Electronics”.

Using the software to make labels

1.

To run the Button-Label Generator program, double-click on the Button-Label

Generator icon (shown at left) in the Extron Electronics group or
folder, and click OK when prompted.

2.

Under System selection, choose SCP 200.  The button label editing area changes
to reflect the number and arrangement of buttons on the device.  Choosing
the SCP 200 will allow you to create two label rows of six buttons each.

3.

Using normal Windows controls, you can create and print labels for the front
panels of the MLS switchers.

4.

Cut the label strips to the appropriate length, and install them in the MLS’s
windows.

For information about using the program, you can access a help file by clicking on
the Help menu on the main screen and choosing Show Help.

You can also see an example of a completed Button-Label Generator window by
clicking on the Help menu on the main screen, choosing Show Help, and clicking on
the Load Demo button.

The following picture shows how the Button-Label Generator screen looks when
set for the SCP 200.

Содержание MLS 306

Страница 1: ...MLS 306 MLS 506 MLS 506MA MLS 506SA MediaLink Switchers 68 598 01 Printed in the USA...

Страница 2: ...n da im Inneren des Geh uses dieses Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das...

Страница 3: ...wer connection 2 6 Input connections 2 6 Video output connections 2 7 Audio output connections 2 8 Audio processing connections MLS 506MA MLS 506SA only 2 10 Control connections 2 11 Setting the 6dB J...

Страница 4: ...program 4 7 User Mode 4 7 Switcher MLS Config 4 8 Saving and restoring configurations 4 9 Using the help program 4 10 Key to file names 4 10 Appendix A Specifications Part Numbers and Accessories A 1...

Страница 5: ...MediaLink Switchers 1 Chapter One Introduction About the MediaLink Switchers Features...

Страница 6: ...d audio output Customizable input labeling Customized input selection button labels can be created by using a labeling machine such as a Brother P touch labeler or you can use Extron software to creat...

Страница 7: ...itchers 2 Chapter Two Installation UL Safety Requirements Mounting the Switcher MLS 306 Rear Panel and Cabling MLS 506 MLS 506MA and MLS 506SA Rear Panels and Cabling Setting the 6dB Jumpers Applicati...

Страница 8: ...register stove or another apparatus including amplifiers that produces heat 4 Unplug the switcher during lightning storms or when it will be unused for long periods Mounting the Switcher Tabletop use...

Страница 9: ...15 pin HD connector for RGB computer video input Each input s audio source can be connected to either the female 3 5 mm mini stereo jack unbalanced input or the 3 5 mm 5 pole captive screw connector b...

Страница 10: ...puts Extron Comm Link cable is recommended for this connection If you use Comm Link cable the switcher and controller can be up to 250 feet 76 2 m apart Wire the captive screw connector for connection...

Страница 11: ...or a third party control system to this 9 pin D connector to set up and remotely control the switcher Alternatively connect a contact closure keypad to this connector for remote control of input selec...

Страница 12: ...INPUT 5 R H HV G V B INPUT 6 R H HV G V B RGB R H HV G V B 4 ohm MONO AMPLIFIED OUTPUT COMM 8 ohm 70V L R L R L R L R AUX MIX EFFECTS L R SEND L R RETURN MLC IR RS232 CONTACT CLOSURE A B C AUDIO OUT F...

Страница 13: ...inputs 4 5 and 6 connect a computer to the appropriate BNC connectors for RGB computer video input RGBHV separate H V sync RGBS composite sync RGsB RsGsBs sync on green or sync on red green blue R H...

Страница 14: ...Audio output connections 7 Mono Amplified Output MLS 506MA only Cable speakers to this output for 30 watt amplified mono audio output This output provides a mono signal even if the input is a stereo s...

Страница 15: ...eaker system to the 100 volt model Connecting a 70 volt speaker system to the 100 volt model can cause damage to the switcher and speakers and create a safety hazard 8 Stereo Amplified Output MLS 506S...

Страница 16: ...ooped through an optional recording device or equalizer before being sent to the main Audio Output 11 preamp outputs or the amplified audio output 7 or 8 We recommend using shielded cables no longer t...

Страница 17: ...O Y C INPUT 2 VIDEO Y C R Y B Y INPUT 3 VIDEO Y C R Y B Y INPUT 4 R H HV G V B INPUT 5 R H HV G V B INPUT 6 R H HV G V B RGB R H HV G V B 4 ohm MONO AMPLIFIED OUTPUT COMM 8 ohm 70V L R L R L R L R AUX...

Страница 18: ...an RS 232 device to the MLS s 9 pin RS 232 Contact Closure port Conflicts between RS 232 signals received from both ports could cause system disruptions When an MLC 206 is connected to the MLC IR port...

Страница 19: ...ins labeled JMP1 and JMP2 on the circuit board as shown in the boxed area of the following picture which shows the pins with the jumpers already set for the 6dB attenuation The MLS 506MA is shown in t...

Страница 20: ...LC 206 VCR DVD Projector Stereo Amplified Output Extron MLS 506SA RS 232 Control Projector Control 100 24 0V 0 2A 50 60 Hz AUD IO OUT INPU T 1 VIDE O Y C R Y B Y L R YUV Y R Y B Y VIDE O S VID EO Y C...

Страница 21: ...MediaLink Switchers 3 Chapter Three Operation Front Panel Features and Basic Operation Menus Configuration and Adjustments Remote Control of the MLS...

Страница 22: ...tion with the IR Link infrared repeater for input selection and volume adjustment Some settings can be adjusted only through a host computer For details on serial communications control via the RS 232...

Страница 23: ...nes how much gain or attenuation is applied to the Aux Mix channel and therefore how loud the auxiliary audio sounds This knob has no function during setup There is no physical limit to this knob s ro...

Страница 24: ...ng the Next button during video configuration causes the current input s number and video format type to be displayed on the LCD Volume Adjust knob In configuration mode rotate this knob to scroll thr...

Страница 25: ...100 steps Adjust bass per input 2dB increments 14dB to 14dB Adjust treble per input 2dB increments 14dB to 14dB Stereo Audio Out outputs stereo audio Mono the Audio Out signal is the same on both left...

Страница 26: ...ndicator on the LCD screen moves toward the left the right audio channel is attenuated As the indicator moves to the right the left audio channel is attenuated In the center no attenuation is applied...

Страница 27: ...or disable executive mode from the main menu press the Menu and Next buttons simultaneously for three seconds as shown below MENU NEXT MENU NEXT Extron MLS 506 X mode enabled X mode disabled Extron ML...

Страница 28: ...Operation cont d MediaLink Switchers Operation 3 8 Troubleshooting x...

Страница 29: ...MediaLink Switchers 4 Chapter Four Serial Communication RS 232 Programmer s Guide Control Software for Windows...

Страница 30: ...racters are required to begin or end a command sequence When the MLS determines that a command is valid it executes the command and sends a response to the host device All responses from the switcher...

Страница 31: ...hex 0D 0A Space Esc Escape key X1 Specific input number 0 7 maximum 0 no connection 1 input 1 Aux Mix 2 input 2 Aux Mix 6 input 6 Aux Mix 7 Aux Mix only X2 Maximum number of input channels 1 6 max X3...

Страница 32: ...audio gain attenuation X8 X4 G In X8 Aud X4 Set a single input s gain attenuation in steps Example 4 53G In X8 Aud 053 Example set input 4 s gain to step 53 Increment a specific input s gain X8 G In X...

Страница 33: ...he volume for the audio output Example 27V Vol013 Example set volume to 13 Increment the volume V Vol X10 Increase audio output Decrement the volume V Vol X10 Decrease audio output View the volume lev...

Страница 34: ...MLS 506MA and MLS 506SA only 0 disabled default 1 enabled Set the left right audio balance 22 X Balance X Set the attenuation applied to the left and right audio channels 0 attenuate the left audio ch...

Страница 35: ...n By default the installation creates a C MediaLnk directory and it places two icons MediaLnk Control Pgm and MediaLnk Help into a group or folder named Extron Electronics Using the control program Ma...

Страница 36: ...t an input The MLS switches to that input s audio source while leaving the previously selected video source active Alternatively you can select the Mixer button to switch to the Mix input s audio The...

Страница 37: ...1 through 3 on an MLS 506 MLS 506MA or MLS 506SA Set the RGB delay period for Triple Action Switching Reset the switcher to factory default settings Saving and restoring configurations The MLS can be...

Страница 38: ...ions click on the tabs in the help screen to reach the desired screen Use a mouse or the Tab and Enter keys to select a button function A description and tips on using the program will appear on scree...

Страница 39: ...MediaLink Switchers A Appendix A Specifications Part Numbers and Dimensions Specifications Part Numbers and Accessories Dimensions...

Страница 40: ...BNCs Minimum maximum levels Analog 0 0V to 2 0V p p with no offset Impedance 75 ohms Horizontal frequency 15 kHz to 150 kHz Vertical frequency 30 Hz to 150 Hz Return loss 45dB 5 MHz Maximum DC offset...

Страница 41: ...ms unbalanced balanced Maximum level 19 5dBu balanced or unbalanced at stated THD N Input gain adjustment MLS 306 MLS 506 15dB to 9dB adjustable per input Input level adjustment MLS 506MA MLS 506SA 1...

Страница 42: ...no parity Serial control pin configurations 2 TX 3 RX 5 GND Contact closure 1 female 9 pin D connector shared with serial control port Contact closure pin configuration pin 1 input 1 pin 4 input 2 pi...

Страница 43: ...rs MLS 506MA SA 10 319 13 Tweeker small screwdriver 100 014 01 MediaLink Switchers User s Manual 68 598 01 MediaLink Switchers Quick Start Guide 68 627 01 Windows based setup software 29 052 01 Access...

Страница 44: ...Specifications Part Numbers and Accessories cont d MediaLink Switchers Specifications Part Numbers and Accessories A 6...

Страница 45: ...MediaLink Switchers B Appendix B Labeling Labeling Buttons on the Switcher Button Label Generator Software Label Templates...

Страница 46: ...tails The Button Label Generator program can be installed separately via the Download page of the Extron Web site http www extron com Follow the on screen directions if you install the program from th...

Страница 47: ...ROOM 1 ROOM 2 1 2 3 4 5 6 7 1 2 3 4 5 6 Each input display and room control can be labeled with names alphanumeric charac ters or bitmapped pictures Each button s label can contain from 1 to 3 lines o...

Страница 48: ...Labeling cont d MediaLink Switchers Labeling B 4 This page is left blank intentionally...

Страница 49: ...tral America Extron Electronics Europe Extron Electronics Beeldschermweg 6C 1230 South Lewis Street 3821 AH Amersfoort Anaheim CA 92805 USA The Netherlands Asia Japan Extron Electronics Japan Extron E...

Страница 50: ...t The Netherlands 31 33 453 4040 Fax 31 33 453 4050 Extron Electronics Asia 135 Joo Seng Road 04 01 PM Industrial Building Singapore 368363 65 383 4400 Fax 65 383 4664 Extron Electronics Japan Daisan...

Отзывы: