Installation, cont’d
MediaLink Switchers • Installation
2-4
Audio output connections
7
Audio Out(put) connectors
— Connect an audio output device to either
connector for balanced or unbalanced stereo audio output. A device such as a
tape recorder can be connected to the Fixed output while a power amplifier
can be connected to the Variable output. Wire each captive screw connector as
shown below.
Unbalanced Output
Tip
See Caution
Sleeve (s)
Tip
See Caution
Balanced Output
Tip
Ring
Sleeve (s)
Tip
Ring
LR
A
UDIO OUT
A
UDIO OUT
LR
CAUTION
Connect the sleeve to ground (Gnd). Connecting the sleeve to a negative
(-) terminal will damage the audio output circuits.
The Fixed connector outputs audio at a fixed level and is unaffected by
changes made via the front panel Volume/Adjust knob. The Variable
connector outputs audio that can be attenuated by turning the Volume knob.
Control connections
8
MLC/IR port
— Connect a cable between this port and an optional Extron
MLC 206 MediaLink Controller or an optional IR Link IR signal repeater.
• The MLC provides remote control of input switching and volume.
• The IR Link accepts modulated IR signals from a remote control so the
remote control can be used for selecting the switcher’s inputs.
Extron Comm-Link cable is recommended for this connection. If you use
Comm-Link cable, the switcher and controller can be up to 250 feet (76.2 m)
apart. Wire the captive screw connector for connection to either an IR Link or
an MLC 206 as shown below.
MLC/IR
A B C
Switcher
rear panel
MLC/IR port
MLS 306 Rear Panel
MLS 306 Rear Panel
MediaLink Switcher to an IR Link
100-240V 0.2A 50/60 Hz
.5A MAX
R
Y/C
B
G
H
AUDIO OUT
FIXED
VARIABLE
INPUT 1
V
VID
INPUT 2
INPUT 3
INPUT 4
INPUT 5
INPUT 6
RGBHV
OUTPUTS
MLC/IR
RS232
CONTACT CLOSURE
A B C
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
100-240V 0.2A 50/60 Hz
.5A MAX
R
Y/C
B
G
H
AUDIO OUT
FIXED
VARIABLE
INPUT 1
V
VID
INPUT 2
INPUT 3
INPUT 4
INPUT 5
INPUT 6
RGBHV
OUTPUTS
MLC/IR
RS232
CONTACT CLOSURE
A B C
L
R
L
R
L
R
L
R
L
R
L
R
L
R
L
R
MediaLink Switcher to an MLC 206
MLC/IR
A B C
MediaLink
Switcher
rear panel
MLC/IR port
NOTE
If you use cable that has a
drain wire, tie the drain wire
to ground at both ends.
MLC
MLS/Power
port
Ground ( )
+12VDC
Transmit (Tx)
B
Receive (Rx)
A
A B
MLS / Power
Transmit (Tx)
Receive (Rx)
+12VDC
Ground ( )
B
A
NOTE
The switcher provides
power to the controller.
A B C D E
A B C
IR
Display/Source Control
Extron Switcher Control
Relays
IR / RCM
RS-232
D E
A B C
A B
D
1A 1B 2A 2B 3A 3B
1 2 3 4 5 6
Tally Out
MLS/Power
33-644-01 A
07 01
Pr
inted in the
USA
MLC 206 Bottom Panel
SIGNAL
IR LINK
Ground ( )
+12VDC
IR (IR Link)
C
IR Link
MLA-Remote
IR Link
port
IR
A B C D E
D
Содержание MLS 306
Страница 1: ...MLS 306 MLS 506 MLS 506MA MLS 506SA MediaLink Switchers 68 598 01 Printed in the USA...
Страница 5: ...MediaLink Switchers 1 Chapter One Introduction About the MediaLink Switchers Features...
Страница 28: ...Operation cont d MediaLink Switchers Operation 3 8 Troubleshooting x...
Страница 29: ...MediaLink Switchers 4 Chapter Four Serial Communication RS 232 Programmer s Guide Control Software for Windows...
Страница 48: ...Labeling cont d MediaLink Switchers Labeling B 4 This page is left blank intentionally...