IPL M PDP-ES • Communication and Control

IPL M PDP-ES • Communication and Control

Communication and Control

There is a 7 character limit for full file names.  It is
advised that you use numeric titles (e.g., 1.eml, 24.eml).
Numeric titles reduce the characters of the file name, and
assist in keeping the alert files organized. However,
alphabetical titles are permitted.

X49

 = Default Name:  combination of model-name and last 3 pairs of

MAC address (e.g., IPL-M-PDP-ES 00-02-3D)

X52

 = Connection’s security level:  00 = anonymous; 11 = user;

12 = Administrator

X69

 = The number of seconds before timeout: (min = 1; max = 65535;

default = 30 = 300 seconds).  If no data is received during the
timeout period, the Ethernet connection is closed.  Each step =
10 seconds. The response is returned with leading zeros.

Applicable to Ethernet only.

X70

 = Number (as optional parameter) inserted into an email message

if .eml file has an embedded ESC CR command with no params.

Copyright information

© COPYRIGHT 2004, EXTRON ELECTRONICS IPL M

PDP-ES, Vx.xx
Thur, 18 Feb 2004 11:27:33
The copyright message is displayed upon connecting to IP
Link product via TCP/IP or Telnet.  Mxx is the model and
Vx.xx is the firmware version number. The current date and
time are displayed. This is followed by a Password prompt.

Password information

The 

Password: prompt requires a password (administrator

level or user level) followed by a carriage return.  The prompt
is repeated if the correct password is not entered.

If the correct password is entered, the unit responds with

Login Administrator

 or 

Login User

, depending on

password entered.  If passwords are the same for both
administrator and user, the unit defaults to administrator
privileges.

Error responses

When the IPL T S interface receives a valid command, it
executes the command and sends a response to the host device.
If the unit is unable to execute the command because the

4-21

X13

 = Set local date and time format (MM/DD/YY-HH:MM:SS)

(e.g., 11/18/04-10:54:00)

Read local date and time format (day of week, date month year
HH:MM:SS) (e.g., Thu, 18 Nov 2004 18:19:33)

X14

 = IP address (xxx.xxx.xxx.xxx)  Leading zeros in each of four fields

are optional in setting values, and are suppressed in returned
values.

X15

 = Mail Domain name (e.g., extron.com, icia.org)

X18

 = Hardware (MAC) address (xx-xx-xx-xx-xx-xx)

X19

 = Subnet mask (xxx.xxx.xxx.xxx); leading zeros in each of four

fields are optional in setting values, and are suppressed in
returned values.

X22

 = Verbose/Response mode: 0 = clear/none; 1 = verbose mode;

2=tagged responses for queries; 3 =v erbose mode and tagged
responses for queries.  Default = 0 for Telnet connections.

If tagged responses are enabled, all read commands
return the constant the data, as setting the
value does.  (e.g.,  Command: Esc CN 

Response:

Ipn •x12

).

X23

 = Priority status for receive timeout: 0 = priority set to Send Data

String command parameters; 1 = priority set to Configure rcv
timeout command parameters.

X25

 = Baud rate: 1200, 2400, 4800, 9600, 19200, 38400

X33

 = Password: allows a maximum length of 12 characters.

User password cannot be assigned if no administrator
password exists and returns E14. If an admin password
is cleared, then the user password is removed too.

X34

 = Daylight saving time: 0 = Off/ignore; 1 = U.S.; 2 =Europe;

3 = Brazil.

X41

Reading Password: If a password exists, it responds with 4
asterisks (****).  If no password exists, it appears empty.

X45

 = Email number:  Range = 1-48 (max.)

X46

 = Email recipient address

X47

 = Name of email file to be sent.  The first line of file is the subject;

the rest is the body of the email.

Email files must have the file extension .eml.

4-20

im Vertrieb von

            CAMBOARD Electronics

www.camboard.de

Tel. 07131 911201
Fax 07131 911203

[email protected]

Содержание IPL M PDP-ES

Страница 1: ...ng Road 04 01 PM Industrial Building Singapore 368363 65 6383 4400 Fax 65 6383 4664 Extron Electronics Japan Daisan DMJ Building 6F 3 9 1 Kudan Minami Chiyoda ku Tokyo 102 0074 Japan 81 3 3511 7655 Fax 81 3 3511 7656 www extron com 2004 Extron Electronics All rights reserved User s Manual IP Link Tools 68 1021 01 Rev A 11 04 IPL M PDP ES im Vertrieb von CAMBOARD Electronics www camboard de Tel 071...

Страница 2: ...nur von qualifiziertem Servicepersonal durchgeführt werden Die internen Komponenten des Gerätes sind wartungsfrei Zur Vermeidung eines elektrischen Schocks versuchen Sie in keinem Fall dieses Gerät selbst öffnen da beim Entfernen der Abdeckungen die Gefahr eines elektrischen Schlags und oder andere Gefahren bestehen Schlitze und Öffnungen Wenn das Gerät Schlitze oder Löcher im Gehäuse aufweist die...

Страница 3: ...information Step 4 Affix the Extron IPL M PDP ES sticker label to the display covering the existing Pioneer label Step 5 Attach the network LAN cable to the LAN port of the IPL M PDP ES interface card installed in the Pioneer plasma Attach the other end to a switch hub router or a host PC as shown below See Ethernet LAN port in chapter 3 for more information on this connection IPL M PDP ES ACT LIN...

Страница 4: ...guring the IPL M PDP ES using direct PC connection 3 6 Configuring the IPL M PDP ES using the RS 232 port 3 7 Firmware upgrades 3 8 Chapter 4 Communication and Control 4 1 Communication with the Interface Card 4 2 Accessing and using the Web server 4 2 Navigating the default Web pages 4 2 Status tab 4 2 Configuration tab 4 3 File Management tab 4 10 Pioneer tab 4 12 Table of Contents QS 2 Step 6 A...

Страница 5: ... 4 21 Error responses 4 21 References to errors 4 22 Command response table for Simple Instruction Set SIS commands 4 23 Pioneer Plasma A V Device Control 4 29 Custom Web pages 4 29 Telnet port 23 4 29 Accessing and using Telnet 4 29 Direct port access port 2001 4 30 Using direct access 4 30 Port redirect 4 31 Troubleshooting 4 31 Power connections 4 31 Data connections 4 31 Serial connections 4 3...

Страница 6: ...lay Compatible Pioneer plasma displays include the following models PDP 504CMX PDP 504CMX S PDP 434CMX PDP 50MXE1 PDP 50MXE1 S PDP 43MXE1 PDP 43MXE1 S About the IPL M PDP ES Interface Card The Extron IPL M PDP ES is an Ethernet based interface card designed to enhance the support and control of Pioneer s fourth generation plasma displays The IPL M PDP ES is powered directly from the plasma and inc...

Страница 7: ... 2 Chapter Two Installation and Operation Installation Overview Installation of the IPL M PDP ES Interface Card Panel Features and Cabling Operation 1 4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Страница 8: ...ps Turn all of the equipment off Make sure that the Pioneer plasma is turned off and disconnected from its power source Remove the Pioneer communication ES card from the plasma Install the Extron IPL M PDP ES interface card Attach the LAN and serial cables to the Extron interface card See Connecting the Hardware in chapter 3 Turn on the devices in the following order serial controller or computer ...

Страница 9: ...hite brown 7 White brown 8 Brown 8 Brown Crossover cable Side 1 Side 2 Pin Wire color Pin Wire color 1 White orange 1 White green 2 Orange 2 Green 3 White green 3 White orange 4 Blue 4 Blue 5 White blue 5 White blue 6 Green 6 Orange 7 White brown 7 White brown 8 Brown 8 Brown Figure 2 7 RJ 45 connector wiring For best performance use a shielded Ethernet cable Power 4 On Off indicator LED The green...

Страница 10: ...ntered in the 2 second time frame the COM port remains or returns to being a control port only A mode 2 reset disconnects a pass through connection Mode 3 Holding the reset button until the Power LED blinks once 3 seconds followed by a momentary 1 second press turns events either On or Off depending on the current state of the events If the events are currently stopped following the momentary 1 se...

Страница 11: ...is mode does the following 1 Enables ARP program capability 2 Sets the IP address back to its factory IP address 3 Sets the Subnet address back to its factory default 4 Sets the Gateway back to its factory default 5 Sets Port mapping back to its factory default 6 Turns DHCP off 7 Turns events off Nothing happens if the momentary press does not occur within one second Mode 5 Holding the reset butto...

Страница 12: ...TCP IP protocol must be installed and properly configured To use the IPL M PDP ES on an existing Ethernet LAN intranet your network administrator can provide you with a unique IP address or confirm whether you need to set up the 3 2 Connecting the Hardware The IPL M PDP ES interface card is housed inside of an expansion slot namely the ES Card Slot of a fourth generation Pioneer plasma Figure 3 1 ...

Страница 13: ...ou to configure the interface card Configuring the IPL M PDP ES using the ARP command You can make use of the ARP Address Resolution Protocol command to set up an IP address for your IPL M PDP ES The ARP command tells your computer to associate the interface card s MAC address with the assigned IP address You must then use ping to access the IPL M PDP ES unit at which point the device server s IP ...

Страница 14: ...M PDP ES default Web page is displayed Refer to Communication with the Interface Card in chapter 4 for information on accessing the Web server 6 After verifying that the change was successful issue the arp d command at the DOS prompt For example arp d 10 13 170 15 removes 10 13 170 15 from the ARP table or arp d removes all static IP addresses from the ARP table Configuring the IPL M PDP ES using ...

Страница 15: ...Control Troubleshooting 3 8 Firmware upgrades Firmware upgrades become available periodically as improvements are made to the versatility and functionality of the IPL M PDP ES interface card These upgrades are available for download from the Extron Web site For details on how to upgrade the firmware see Upgrading the firmware in chapter 4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07...

Страница 16: ...word protected see Passwords page later in this chapter If you are unable to access the Web server see Troubleshooting at the end of this chapter Navigating the default Web pages The IPL M PDP ES default Web pages include four tabs Status Configuration File Management and Pioneer for easy navigation of several administrative options including system status password control file management and cont...

Страница 17: ... some of these fields follow Unit Name This name field can be changed to any valid name up to 12 alphanumeric characters The following characters are invalid in the unit name space and DHCP The Dynamic Host Configuration Protocol DHCP is an Internet protocol for automating the configuration of computers that use TCP IP DHCP can be used to automatically assign IP addresses deliver TCP IP stack conf...

Страница 18: ...ice once in the Password field and then again in the Re enter Password field Characters in these fields are masked by asterisks The following characters are invalid in passwords space and As shown in figure 4 4 password protected connections allow two levels of protection administrator and user Administrators have access to status information and all function control Users have access to status in...

Страница 19: ...ew email alerts within the Web server do the following 6 Obtain your gateway IP address from your system administrator 4 8 7 Click System Settings on the menu figure 4 2 on the left side of the window 8 Place the gateway IP address into the Gateway IP Address field 9 Click the Submit button Sending an email alert through Telnet To complete the process of sending an email alert you must send it thr...

Страница 20: ...useful tool that allows you to use and upload existing and custom Web pages Custom pages can be developed using a third party Web page development program such as FrontPage or Dreamweaver File management also allows you to remove unnecessary or outdated files when they are no longer needed To add or update files 1 Select the File Management tab The File Management screen figure 4 8 is displayed Fi...

Страница 21: ...default page of the Pioneer tab and allows users to view the description and current status of the Pioneer plasma Figure 4 9 Pioneer Display Status screen Display Controls page The Display Controls page figure 4 10 is accessible from the Controls link on the left side of the window According to password level the buttons and fields on this page allow you to control and or view the status of the Pi...

Страница 22: ... display s multi screen function allows the simultaneous display of two inputs PIP allows a subscreen to display in one of the six areas of the main screen This function can be toggled off or on See the Pioneer Operating Instructions for additional information Advanced Controls page The Advanced Controls page figure 4 11 is accessible from the Advanced link on the left side of the window Explanati...

Страница 23: ...lendar options and schedule the time and date of the weekly event figure 4 13 Figure 4 13 Pioneer Schedule calendar 4 Click Save to submit the schedule For Users this is a view only function 4 16 Monitor page Using the Monitor page figure 4 13 you can monitor power levels internal temperature and usage of the Pioneer plasma An email notification can be sent to a recipient when specified conditions...

Страница 24: ...All commands listed below will work using either connection method but due to some limitations of the Web browser the encapsulation characters are modified to make sure that the Web browser will properly handle them All examples in the command response table show the proper implementation in a Telnet or Web browser session Note for Web browsers all non alphanumeric characters must be represented a...

Страница 25: ...s a valid command it executes the command and sends a response to the host device If the unit is unable to execute the command because the 4 21 X13 Set local date and time format MM DD YY HH MM SS e g 11 18 04 10 54 00 Read local date and time format day of week date month year HH MM SS e g Thu 18 Nov 2004 18 19 33 X14 IP address xxx xxx xxx xxx Leading zeros in each of four fields are optional in...

Страница 26: ...A0 2A3DCE Cpn1 Cce400 200 0 3D View receive timeout Esc 1CE W1CE 00400 00200 0 00003D Set redirect mode 24 Esc 2 1 500 3DCD W2 2A1 2A500 2A3DCP Cpn 2 Ccd 1 00500 00003D Terminated redirect mode 24 Esc 1 0CD W1 2A0CD Cpn 1 Ccd 00000 00000 00000L View redirect mode Esc 1CD W1CD 00002 00500 00003D Firmware Version Part Number Information Query firmware version Q Q X11 Query verbose version informatio...

Страница 27: ...4 View gateway IP address 24 Esc CG WCG X14 Set verbose mode 24 Esc X22 CV W X22 CV Vrb X22 View verbose mode Esc CV WCV X22 Get connection listing Esc CC WCC Number of connections 4 24 Command ASCII Telnet URL Encoded Web Response Password and Security Settings Set administrator password 24 Esc X33 CA W X33 CA Ipa X41 Clear administrator password 24 Esc CA W 20CA Ipa View administrator password 2...

Страница 28: ... WMT port Set Web port map 24 Esc port MH W port MH Pmh port Command ASCII Telnet URL Encoded Web Response Re map port designations continued Reset Web port map 24 Esc 80MH W80MH Pmh 00080 Disable Web port map 24 Esc 0MH W0MH Pmh 00000 View Web port map 24 Esc MH WMH port Set Direct Access port map 24 Esc port MD W port MD Pmd port Reset Direct Access port map 24 Esc 2001MD W 2001MD Pmd 02001 Disa...

Страница 29: ... ways These include Web pages Telnet and direct port access Custom Web pages These pages can be either modified versions of the existing Web pages or new Web pages developed in the field Web page development can be done with a Web site development tool such as FrontPage or Dreamweaver Custom Web pages are loadable with the Web server File Manager see File Management tab earlier in this chapter If ...

Страница 30: ...ection for detailed instructions You can force the direct access session to close by logging on as administrator and entering Esc 1 0CD Port redirect Using the port redirector the card allows data to be sent and received directly to and from the display and back to the client e g a PC or the MLC 206 without any processing 1 Open another Telnet session see the previous section for details 2 Reestab...

Страница 31: ...card baud rate matches that of the control device e g a PC or the MLC 206 If status is missing or unavailable check the following 1 Ensure that the Pioneer plasma ID is set to 01 see the Pioneer plasma documentation for details 2 Check that the IPL M PDP ES interface card baud rate matches that of the control device e g a PC or the MLC 206 3 Ensure that the redirect port has been enabled If you ar...

Страница 32: ...lex level autodetected IP address 192 168 254 254 subnet mask 255 255 0 0 default gateway 0 0 0 0 DHCP off Serial control interface Port number type 1 RS 232 Connectors 1 9 pin female D Baud rate and protocol 1200 2400 4800 9600 default 19200 38400 baud adjustable 8 data bits 1 stop bit no parity Pin configurations RS 232 2 RX 3 TX 5 GND General Power Supplied by a Pioneer plasma display Temperatu...

Страница 33: ...ions Part Numbers and Accessories Specifications Part Numbers Accessories cont d IPL M PDP ES B Appendix B Glossary A 4 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Страница 34: ...ests network connections It is used to determine if the host has an operating connection and is able to exchange information with another host B 2 GLOSSARY 10 100Base T is Ethernet that uses Unshielded Twisted Pair UTP Cat 5 etc cable in which the amount of data transmitted between two points in a given amount of time is equal to either 10 Mbps or 100 Mbps Address Resolution Protocol ARP is a prot...

Страница 35: ... Protocol TCP IP is the communication protocol language of the Internet Computers and devices with direct access to the Internet are provided with a copy of the TCP IP program to allow them to send and receive information in an understandable form Telnet is a utility available on most PCs that allows the computer system to communicate with one of its remote users clients A user who wishes to acces...

Страница 36: ...IPL M PDP ES Glossary Glossary cont d B 6 im Vertrieb von CAMBOARD Electronics www camboard de Tel 07131 911201 Fax 07131 911203 ce info camboard de ...

Отзывы: