FOX3 T 201 Transmitter • SIS Configuration and Control
23
Command Function
SIS Command
(Host to Unit)
Response
(Unit to Host)
Additional description
Information requests (continued)
Information request
Verbose mode 2/3:
I
SFPALnk
X2*
•
SFPBLnk
X2*
•
SigI
X$
•
HdcpI
X^
•
Hdcp
O
X&
•
AudI
X*
•
X(
•
X2(]
Inf00*SFPALnk
X2*
•
SFPBLnk
X2*
•
SigI
X$
•
HdcpI
X^
•
Hdcp
O
X&
•
AudI
X*
•
X(
•
X2(]
Response description:
Fiber link A•Fiber link B•Signal input•Input HDCP•Output HDCP•Input audio•Transmitter•Fiber mode
]
Example:
I
SFPALnk1
•
SFPBLnk1
•
SigI1
•
HdcpI1
•
HdcpO1
•
AudI1
•
TX
•
SM
]
Signals are detected on the two fiber links, a signal is detected on the
input, the input and output are HDCP devices, the digital audio input is
selected, the device is a transmitter, and the fiber mode is singlemode.
KEY:
X$
= Input video signal status
0
= Not detected
1
= Detected
X^
= Input HDCP status
0
= No source detected
1
= Source with HDCP detected (
default
)
2
= Source with no HDCP present
X&
= Output HDCP status
0
= No active sink detected
1
= Sink detected, output encrypted
2
= Sink detected, output not encrypted
X*
= Input audio selection
0
= Auto
1
= Digital
2
= Analog
X(
= Device type
TX
or
RX
X2*
= Fiber link detection
0
= Not detected
1
= Detected
X2(
= Fiber optic mode
SM
or
MM
View LinkLicense
E
LELIC
}
FOX3 Uncompressed Video, 79-2560-01
]]
If LinkLicense is not installed, returns
]]
DHCP client
Set DHCP on or off
E
X1)
DH
}
Idh
X1)]
View DHCP status
E
DH
}
X1)]
KEY:
X1)
= Set DHCP
0
= Off (
default
)
1
= On
Telnet port
Set Telnet port map
E
Z
X3$
PMAP
}
PmapZ
X3%]
Sets Telnet port map to
X3$.
View Telnet port map
E
ZPMAP
}
X3%]
KEY:
X3$
= Enable Telnet port 23
0
= Off (
default
)
23
= Telnet port 23 enabled
X3%
= Port number
Response is 5 digits with leading zeros, for example
00000
or
00023
Echo for SIS over SSH (port 22023)
Enable Echo
E
1ECHO
}
Echo1
]
Returns command entered with
response.
Disable Echo
E
0ECHO
}
Echo0
]
Returns response only.
View Echo status
E
ECHO
}
X3)]
NOTE:
This command is only applicable to the SIS over SSH connection using the LAN or USB ports.
KEY:
X3)
= On or off
0
= Off
1
= On (
default
)
Verbose mode
Set verbose mode
E
X1&
CV
}
Vrb
X1&]
View verbose mode
E
CV
}
X1&]
NOTE:
Verbose mode reverts back to default in the event of a power cycle, disconnect from dataviewer, or disconnect from the Ethernet.
KEY:
X1&
= Verbose mode
0
= Clear/none (
default for Ethernet
)
1
= Verbose mode (
default for RS-232
)
2
= Tagged response for queries
3
= Verbose mode and tagged responses for queries
Содержание FOX3 T 201
Страница 1: ...User Guide FOX3 T 201 Fiber Optic Extender Fiber Optic HDMI Transmitter 68 2865 01 Rev A 03 21...
Страница 2: ...Safety Instructions...
Страница 6: ......
Страница 8: ...FOX3 T 201 Transmitter Contents viii...