Installation 
Overview

This section provides an overview of the five stages of installation for the VoiceLift 
system and the steps required for each stage.

Stage 1 — Install the VLR 102 Receiver

Choose one of these installation types:

1a. Drop ceiling

c

 

Cut a hole in the ceiling tile

 (page 17).

c

 

Mount the receiver housing to the ceiling tile

 (page 17).

c

 (Optional) 

Attach a conduit to the back plate if needed

 (page 17).

1b. Junction box

c

 

Install the junction box 

(page 18).

c

 

Attach the receiver housing to the junction box

 (page 18).

c

 

Attach a conduit to the junction box if needed 

(page 18).

1c. Wall or other hard surface

c

 

Install a raceway if needed

 (page 19).

c

 

Mark the mounting screw hole locations on the surface

 (page 19).

c

 

If using a raceway, remove the appropriate knockout in the receiver  

 housing

 (page 19).

Mount the receiver housing to the surface

 (page 20).

1d. Pole

c

 

Attach the pole to the ceiling

 (page 21).

c

 

Mount the receiver housing to the pole

 (page 21).

Stage 2 — Install the FF 120 Speakers (VLS Only)

c

 

Cut the ceiling tile

 (page 23).

c

 

Install the speakers in the drop ceiling 

(page 23).

c

 

(Optional)

 Install a seismic safety cable at each speaker location 

(page 24).

c

 

Terminate the speaker cable for the PVS switcher

 (page 24).

Stage 3 — Install the PVS 405D Switcher (VLS Only)

c

 

Install the PoleVault switcher 

(page 26). 

 

See the 

PoleVault Systems Featuring the PVS 405D Switcher Installation Guide 

 

 

for the procedures. 

VoiceLift System with PVS 405D Installation Guide

 • 

Installation — Overview

13

Содержание FF 120

Страница 1: ...Installation Guide VoiceLift 68 2548 20 Rev B 06 14 VoiceLift Microphone System Featuring PVS 405D PoleVault Digital Switcher...

Страница 2: ...f aufmerksam machen dass im Inneren des Geh uses dieses Produktes gef hrliche Spannungen herrschen die nicht isoliert sind und die einen elektrischen Schlag verursachen k nnen VORSICHT Dieses Symbol a...

Страница 3: ...e the properties of their respective owners The following registered trademarks registered service marks SM and trademarks TM are the property of RGB Systems Inc or Extron Electronics Registered Trade...

Страница 4: ...C 01 R000400300004000080000600 02 35 17 03 EX X1 X2 X2 X2 CE NOTE For commands and examples of computer or device responses mentioned in this guide the character 0 is used for the number zero and O i...

Страница 5: ...ng the Receiver 15 Receiver Housing and Back Plate 15 Z bracket and Mounting Screw for Installation in a Drop Ceiling 15 Stage 1a Installing the Receiver in a Drop Ceiling 17 Stage 1b Installing the R...

Страница 6: ...VoiceLift System with PVS 405D Installation Guide Contents vi...

Страница 7: ...par le personnel autoris uniquement UL listed electrical boxes are recommended Extron recommande d installer le VLR 102 dans un bo tier d encastrement lectrique mis la terre list UL About the VoiceLi...

Страница 8: ...G E x t r o n P W R C H A R G E O F F M U T E C H G O N Extr on CONFIG DISPLAY MLC 104 IP Plus VOLUME 1 2 3 4 ON OFF VIDEO AUX VIDEO IMAGE MUTE PC COMPUT ER IN AUDIO IN AUDIO IN L R VIDEO IN PVS 405D...

Страница 9: ...tions on the next page L R DO NOT GROUND OR SHORT SPEAKER OUTPUTS 4 8 3A MAX POWER 12V HDMI 1 2 SIG LINK SIG LINK 3 4 INPUTS OUTPUT AUDIO OUT PVS 405D AMPLIFIED AUDIO OUT PAGING SENSOR PVT IN PVT IN L...

Страница 10: ...possible cover windows and skylights with curtains blinds or other covering options Plasma displays Avoid placing plasma displays in close proximity to the microphone system Electrical equipment Take...

Страница 11: ...structions to the IR signal into consideration when placing the receiver Movable furniture such as desks tables and podiums Installed furniture such as bookcases racks cabinets workbenches and sinks S...

Страница 12: ...m Ideal conditions for reflection are light colored smooth surfaces for example white drywall Items to consider that may affect reflection include Ceiling type such as drop spline or hard lid Wall typ...

Страница 13: ...to the microphone Avoid the corners of the room alcoves bays or sheltered areas that can restrict coverage If the ceiling is over 12 feet 3 6 meters high consider mounting the receiver on a pole to re...

Страница 14: ...ure du plafond pourrait provoquer des blessures graves voire mortelles V rifier la structure du plafond afin de vous assurer qu il peut supporter une charge quatre fois sup rieure au poids de l instal...

Страница 15: ...nt Microphone a VLR 102 Receiver a wall charger and two FF 120 Flat Field speakers VLS 2000D Contains two VLP 102 Pendant Microphones a VLR 102 Receiver a wall charger a VLC 102 Charging Station and t...

Страница 16: ...PVS 405D Installation Guide Introduction 10 NOTE If any items in the VoiceLift System or FF 120 boxes are damaged or missing contact the Extron S3 Sales and Technical Support Hotline see the rear cove...

Страница 17: ...that the VoiceLift System is properly installed 3 4 inch Extension Bit for Drilling Through Fire Breaks Power Drill Tools for Terminating Cable Vacuum Cleaner Safety Goggles Utility Knives Screw Drive...

Страница 18: ...rical ceiling box Junction box Plaster ring Raceway Bolts for concrete structural ceilings where needed Dry wall anchors and screws Spare ceiling tiles in case of accidental damage during installation...

Страница 19: ...ded page 19 c Mark the mounting screw hole locations on the surface page 19 c If using a raceway remove the appropriate knockout in the receiver housing page 19 c Mount the receiver housing to the sur...

Страница 20: ...has a circled number corresponding to the step that is being described NOTES Additional installation hardware is needed for this installation and should be supplied by the installer see Items Not Incl...

Страница 21: ...ceiver base plate and connectors The housing contains knockouts for different sizes of raceways and the back plate contains knockouts for a conduit Z bracket and Mounting Screw for Installation in a D...

Страница 22: ...ft Receiver in a Drop Ceiling page 17 Stage 1b Installing the VoiceLift Receiver to a Junction Box page 18 Figure 11 Diagrams of Stage 1 Mounting Options NOTE Observe all local and national building a...

Страница 23: ...sert the ceiling bracket screw through the back plate attached to the housing and the hole in the ceiling tile b Attach the Z bracket loosely to the screw on the back side of the ceiling tile c Align...

Страница 24: ...hoc lectrique ou des blessures graves Toute installation lectrique devrait tre effectu e par un personnel qualifi conform ment aux codes du b timent aux codes incendie et s curit et aux codes lectriqu...

Страница 25: ...crew holes in the receiver housing as guides to mark the screw locations on the mounting surface 3 If using a raceway remove the appropriate knockout in the receiver housing a Use a knife to score aro...

Страница 26: ...ng the appropriate screws for the type of surface NOTE Screws and wall anchors are not included If using a raceway Position the receiver housing with the raceway inserted through the knockout 4 Mounti...

Страница 27: ...le a Remove a large knockout from the receiver back plate to accommodate the inch 19 mm pole see figure at right b Attach a inch 19 mm clamp compression or set screw connector to the other end of the...

Страница 28: ...Rings 2 Cable Clamps 2 Terminal Cover T rails 2 FF 120 Speakers 2 Seismic Tabs 1 at each end Figure 12 FF 120 Ceiling Speaker Where they go Installed in ceiling tiles at locations selected for best ac...

Страница 29: ...s 12 inches 30 cm from one end of the T frame The speaker will be placed into the small section b Remove the terminal cover from the rear of a speaker and attach the anchor ring and cable clamp to the...

Страница 30: ...s c Pass the other end of the cable up through the lag eye bolt see step 3a and twist that end around the cable five times ATTENTION Repeated bending of the tab may cause it to break off Le fait de pl...

Страница 31: ...t for dual mono output Use the Universal Switcher Control software or the Extron Special Instruction Set SIS commands to change the setting to stereo if desired For full details see the PoleVault Syst...

Страница 32: ...ives input video and audio signals from the AV source input wall plates and audio signals from the VoiceLift VLR 102 Receiver Outputs and switches the signals to a projector and ceiling speakers L R D...

Страница 33: ...PVS 405D following the instructions in the PoleVault Systems Featuring the PVS 405D Switcher Installation Guide and the provided mounting kit user guide 3 Make sure that the PVS 405D front and rear p...

Страница 34: ...IR sensors inside captive screw connectors for auxiliary input RS 232 contact input and relay output RJ 45 connectors for power communication and audio output and DIP switches STP Cable Figure 17 STP...

Страница 35: ...e receiver to a wall and using a raceway place the cables in the raceway and replace the raceway cover 2 Connect the cables to the receiver a Connect the STP cable to the Receiver Out port the RJ 45 c...

Страница 36: ...e noise 3 Attach the receiver dome to the housing a Place the dome onto the housing aligning the arrow etched on the dome locking tab with the raised arrow on the housing rim The two tabs in the housi...

Страница 37: ...he cables to the PoleVault switcher a Remove the bottom covers of the PMK 560 projector mount b Pull the cables from the receiver and from the speakers in VLS systems to the PoleVault switcher locatio...

Страница 38: ...al Left and Right Audio Output to Speakers VoiceLift Receiver Figure 18 Connecting the Receiver to a PVS 405D Switcher 5 Connect the cables to the PoleVault switcher a Disconnect the power cable from...

Страница 39: ...ls A and B If the student is using a pendant microphone it is recommended that you disable the volume buttons by setting the channel to C or D This prevents the student from inadvertently pressing bot...

Страница 40: ...ceLift feedback suppressor eliminates feedback from the microphone Follow these steps to achieve the best performance from the FBS a Power on the VoiceLift system The Power LEDs on the microphone and...

Страница 41: ...e microphone stops beeping f Slowly raise the microphone gain level on the PVS switcher while talking into the microphone until feedback occurs One click of the encoder is 1 dB The dynamic filters beg...

Страница 42: ...and installation of the PoleVault switcher if necessary PEAK NORMAL SIGNAL Signal threshold 20 dBV 18 dBu Level has been properly adjusted Level set too high Lower input gain Check the PVS switcher LE...

Страница 43: ...f the Rly port to the receiver using a jumper between the common pin and the ground pin on the Contact input CTC the Aux Input Aux In or the RS 232 port see the illustration at right Installation Exam...

Страница 44: ...obal Configurator help file 3 Test the instant alert notification a Ensure that the MLC 104 IP Plus is connected to the network b Press and hold the two Volume buttons on the microphone simultaneously...

Страница 45: ...b Emirates Dubai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or if modifications wer...

Страница 46: ...31 33 453 4050 FAX Extron Asia 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 86 21 3760 1568 86 21 3760 1566 FAX Extron Middle East 971 4 299 1800 971 4 29...

Отзывы: