background image

 

5

Product Category

Retractor bracket

Use the retractor bracket to mount retractors in the Cable 
Cubby enclosure. The retractor bracket accommodates 
up to three Retractor Series/2 or Retractor Series/2 
XL cable retraction modules. The retractors must be 
purchased separately.
If you require retractors, insert the retractor bracket as 
shown in figure 5.

NOTE:

  Do not mount the retractors in the retractor 

bracket until after the Cable Cubby is mounted 
(see 

Install the Retractors

 on page 7).

Install retractor filler modules (see 

www.extron.com

) in 

any unused retractor mounting spaces.
Optional retractor brackets (see 

www.extron.com

) each 

accommodate two cable retraction modules. These 
brackets must be purchased separately. They are sold 
in pairs and allow the cable retractors to be mounted at 
the outer edges of the enclosure with one of the other 
modules mounted centrally. 

Secure the bracket using four of 

the provided pan-head mounting 

screws with star washers. Tighten 

the screws using a screwdriver.

Insert the bracket as shown.

Se

the

e

ON

OF

F

PC

LAPTOP

MUT

E

AUX

 VIDE

O

VGA

HD

MI

e

21-525-

01L

F

The bracket may be installed on the

left or right side of the enclosure and

at the lowest height.

2

1

Figure 5. 

Install the Retractor Bracket

AAP module, cable pass-through module and power module

Insert the modules into the cable cubby as shown in 
figure 6.

NOTE:

  Extron recommends mounting the power 

module on the left side of the enclosure.

AC power and AC+USB power modules are available 
for US, Europe, and other major world markets. They 
must be purchased separately (see 

www.extron.com

).

Most AC power modules provide two unswitched AC 
outlets.
The AC+USB power modules provide one or two AC 
outlets and two USB power outlets.

WARNING:

  Risk of Electric Shock. To ensure 

proper electrical grounding, use the 
provided #6-32 mounting screws with the 
star washers.

AVERTISSEMENT :

 

 Risque de choc électrique. 

Afin d’assurer une mise à la terre correcte, 
utilisez les fixations de mise à la terre #6-32 et 
les rondelles en étoile fournies.

125V

~ 1

2A 

MA

X T

OT

AL

e

ON

OF

F

PC

LAPTOP

MUT

E

AU

X VIDE

O

VGA

HD

MI

e

21-525-

01LF

Secure the modules using

four of the provided

pan-head mounting screws

and star washers.

Insert the modules 

into the Cable Cubby.

2

1

Figure 6. 

Install the Connectivity and Power Modules

Содержание EBP 1200C

Страница 1: ...t RS 232 VGA Figure 1 EBP 1200C Application Diagram Setup Checklist Step 1 Planning Download and install the latest version of the software firmware and device drivers needed to configure the IPCP Pro...

Страница 2: ...F e ON OFF PC LAPTOP MUTE AUX VIDEO VGA HDMI Item Qty Item Qty Item Qty 1 EBP 1200C 1 6 Retractor Pin and Clip 1 9 4 40 Module Screws 8 2 Connectivity Bracket 1 7 Hole Plugs 6 3 8 2 1 4 3 AAP Frame Pl...

Страница 3: ...particuli rement attention la directions dans laquelle l unit sera dirig e Le c t pour acc der au connecteurs est soulign voir CNC Wood Router ci dessous Extron ne sera pas responsable des erreurs de...

Страница 4: ...plate You may need to bend the plate gently to slide the cable past the slot opening Snap the included hole plugs into any unused holes 1 3 Figure 3 Assembling the AAP Module NOTE After assembling the...

Страница 5: ...OFF PC LAPTOP MUTE AUX VIDEO VGA HDMI e 21 5 25 0 1LF The bracket may be installed on the left or right side of the enclosure and at the lowest height 2 1 Figure 5 Install the Retractor Bracket AAP m...

Страница 6: ...move the plastic strips and film on the surface of the Cable Cubby Ensure that the side clamps are seated against the enclosure Lower the Cable Cubby into the hole to test the fit If necessary careful...

Страница 7: ...o not overtighten 2 3 1 4 Figure 9 Installing Retractors Horizontal Mounting Remove two enclosure screws one on each side from this position Then mount the Retractors as shown at left Cable Release As...

Страница 8: ...MUTE button to the right E Button panel removal slots Use the Extron removal tool in these slots to release the top of the panel when replacing buttons F Input and function buttons If these buttons a...

Страница 9: ...ons without the panel becoming completely detached You can now return the lid to the fully open position 5 5 From the front of the panel press the button until it is free of the panel 6 6 From the bac...

Страница 10: ...he diagrams in this section as a guide NOTES By factory default the EBP 1200C is set to address 26 binary 011010 as shown in the diagram below Any address can be used except address 0 binary 000000 Th...

Страница 11: ...er an EBP from more than one power source ATTENTION Always use a power supply supplied or specified by Extron Use of an unauthorized power supply voids all regulatory compliance certification and may...

Страница 12: ...1200C eBUS 24 WATTS MAX 100 240V 50 60Hz 0 6A MAX S V S G S V S G S V S G S V S G S V S G S V S G RESET eBUS Status ON M S B BUS ID 1 2 3 4 5 6 V LINK COM ERROR ID ERROR S S S G V S G L S B PWR LOAD 2...

Страница 13: ...een set up you can use Global Scripter to program buttons and LEDs Test and Troubleshoot 1 Verify that the DIP switches on the EBPs are set to the desired address on each unit and that there are no DI...

Страница 14: ...ia 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 86 21 3760 1568 86 21 3760 1566 FAX Extron Middle East 971 4 299 1800 971 4 299 1880 FAX Extron Australia 6...

Отзывы: