1
Product Category
TANT
:
Go to
for th
e
complete user guide and installation
instructions befor
e connecting the
product to the power sou
rce.
EBP 108 RAAP Button Panel • Setup Guide
The Extron eBUS
®
108 RAAP Button Panel (EBP) is a fully-customizable AV system control interface with eight buttons and a
rotary encoder and eight-segment LED level indicator. It is designed for use with Extron eBUS-enabled Pro control systems. The
1U, 19 inches wide metal frame can be mounted in any standard equipment rack and the mounting plate has openings for up to
four single-space or two double-space AAP
™
Architectural Adapter Plates.
NOTE:
These products are for use only with Extron UL Listed IPCP Pro control processors.
The EBP 108 RAAP has four eBUS ports that support power and communications between the IPCP Pro control processor
and eBUS devices, and also accommodate system expansion. Up to eight eBUS endpoint devices such as EBP button panels
and ECM control modules can be connected to the control processor and to each other in various cabling topologies. Cabling
topology refers to the physical layout of cabling interconnections between devices in a network such as an eBUS system. eBUS
systems can include daisy-chain, star, or a combination of both topologies (see the
eBUS Technology Reference Guide
, available
,
for basic diagrams). Every endpoint device must have a unique identification address (bus ID) within the
system.
Setup involves setting bus ID DIP switches on the EBPs, then using Extron Global Configurator
®
Plus and Professional (GCP)
configuration software, the Toolbelt utility software, or Global Scripter
®
programming software to configure the control processor.
Once configured, the panels can be used for AV system control.
This guide provides basic instructions for an experienced installer to install any of these panels. For more details on the EBPs, see
the
eBUS Technology Reference Guide
. For details on configuration, see the software help files.
Features
Rear Panel Features
EBP 108 RAAP
M
S
B
L
S
B
BUS ID
1
ON
2 3 4 5 6
LINK
COM ERROR
ID ERROR
STATUS
RESET
POWER LOAD = 0.5 W
+V +S -S G +V +S -S G +V +S -S G
+V +S -S G
eBUS DISTRIBUTION HUB
EBP 108 RAAP Rear Panel
A
A
A
A
B
B
C
C
D
D
B
B
E
E
F
F
Figure 1.
EBP Rear Panel Features
A
Rack Mounting Holes
— Used to mount the device to standard 19-inch equipment racks (see
page 10).
B
AAP Mounting Slots
— Used to mount up to four single-space or two double-space AAPs.
C
BUS ID DIP Switches
— Up to eight devices can be connected to one control processor. Each device connected to the
same control processor must have a unique BUS ID, which is set using DIP switches (see
D
Status LEDs
— The EBP 108 RAAP has yellow, red, and green LEDs that provide diagnostic information about the
connection, communication, and power status of the panels. For more information about how the LEDs are used for
troubleshooting, see
E
eBUS Distribution Hub
(4 ports) — The four-pole captive screw connectors use the Extron eBUS protocol to connect the
panel to a controller and to other panels (see
F
Reset Button
— If required, press this recessed button to reset the firmware to the factory installed version.
figure 1