Extron electronics EBP 108 RAAP Button Panel Скачать руководство пользователя страница 1

1

Product Category

IMPOR

TANT

:

Go to

 

www

.extron.com

 for th

e

complete user guide and installation

instructions befor

e connecting the

product to the power sou

rce.

www

.extro

n.com

EBP 108 RAAP Button Panel • Setup Guide

The Extron eBUS

®

 108 RAAP Button Panel (EBP) is a fully-customizable AV system control interface with eight buttons and a 

rotary encoder and eight-segment LED level indicator. It is designed for use with Extron eBUS-enabled Pro control systems. The 
1U, 19 inches wide metal frame can be mounted in any standard equipment rack and the mounting plate has openings for up to 
four single-space or two double-space AAP

 Architectural Adapter Plates.

NOTE:

  These products are for use only with Extron UL Listed IPCP Pro control processors.

The EBP 108 RAAP has four eBUS ports that support power and communications between the IPCP Pro control processor 
and eBUS devices, and also accommodate system expansion. Up to eight eBUS endpoint devices such as EBP button panels 
and ECM control modules can be connected to the control processor and to each other in various cabling topologies. Cabling 
topology refers to the physical layout of cabling interconnections between devices in a network such as an eBUS system. eBUS 
systems can include daisy-chain, star, or a combination of both topologies (see the 

eBUS Technology Reference Guide

, available 

at 

www.extron.com

,

 for basic diagrams). Every endpoint device must have a unique identification address (bus ID) within the 

system.
Setup involves setting bus ID DIP switches on the EBPs, then using Extron Global Configurator

®

 Plus and Professional (GCP) 

configuration software, the Toolbelt utility software, or Global Scripter

®

 programming software to configure the control processor. 

Once configured, the panels can be used for AV system control.
This guide provides basic instructions for an experienced installer to install any of these panels. For more details on the EBPs, see 
the 

eBUS Technology Reference Guide

. For details on configuration, see the software help files.

Features

Rear Panel Features

EBP  108  RAAP

M

S

B

L

S

B

BUS ID

1

ON

2 3 4 5 6

LINK

COM ERROR

ID ERROR

STATUS

RESET

POWER  LOAD = 0.5 W

+V +S -S G +V +S -S G +V +S -S G

+V +S -S G

eBUS DISTRIBUTION HUB

EBP 108 RAAP Rear Panel

A

A

A

A

B

B

C

C

D

D

B

B

E

E

F

F

Figure 1. 

EBP Rear Panel Features

A

 

Rack Mounting Holes

 — Used to mount the device to standard 19-inch equipment racks (see 

Step 8: Mount the EBPs

 on 

page 10).

B

 

AAP Mounting Slots

 — Used to mount up to four single-space or two double-space AAPs.

C

 

BUS ID DIP Switches

 — Up to eight devices can be connected to one control processor. Each device connected to the 

same control processor must have a unique BUS ID, which is set using DIP switches (see 

Step 4: Set BUS ID Addresses

 on 

page 4).

D

 

Status LEDs

 — The EBP 108 RAAP has yellow, red, and green LEDs that provide diagnostic information about the 

connection, communication, and power status of the panels. For more information about how the LEDs are used for 
troubleshooting, see 

Step 7: Test and Troubleshoot

 on page 9.

E

 

eBUS Distribution Hub

 (4 ports) — The four-pole captive screw connectors use the Extron eBUS protocol to connect the 

panel to a controller and to other panels (see 

Step 5: Cable All Devices

 on page 7).

F

 

Reset Button

 — If required, press this recessed button to reset the firmware to the factory installed version.

figure 1

Содержание EBP 108 RAAP Button Panel

Страница 1: ...figurator Plus and Professional GCP configuration software the Toolbelt utility software or Global Scripter programming software to configure the control processor Once configured the panels can be us...

Страница 2: ...ith Global Configurator Plus and Professional or programming with Global Scripter see the software help file for more information C Volume Control LEDs and Rotary Encoder Use the encoder to adjust the...

Страница 3: ...use a piece of sticky tape to pull it out of the button cap 4 Select one of the button labels from the printed label sheets included with the unit Remove the label from its backing and remove the cle...

Страница 4: ...ff 22 4 3 Off 23 8 6 Off 20 1 Slide 1 2 3 4 5 6 ON M S B L S B BUS ID Figure 5 eBUS ID Setup Add the decimal numbers for each of the DIP switches that are set to On to obtain the address of the device...

Страница 5: ...4 5 6 ON M S B L S B 0 0 0 1 0 0 4 1 2 3 4 5 6 ON M S B L S B 0 1 0 0 1 1 19 1 2 3 4 5 6 ON M S B L S B 0 0 0 1 0 1 5 1 2 3 4 5 6 ON M S B L S B 0 1 0 1 0 0 20 1 2 3 4 5 6 ON M S B L S B 0 0 0 1 1 0...

Страница 6: ...6 1 2 3 4 5 6 ON M S B L S B 1 1 0 1 0 1 53 1 2 3 4 5 6 ON M S B L S B 1 0 0 1 0 1 37 1 2 3 4 5 6 ON M S B L S B 1 1 0 1 1 0 54 1 2 3 4 5 6 ON M S B L S B 1 0 0 1 1 0 38 1 2 3 4 5 6 ON M S B L S B 1 1...

Страница 7: ...source are isolated from the devices powered by the second source by see figure 7 on the following page ATTENTION Always use a power supply supplied or specified by Extron Use of an unauthorized power...

Страница 8: ...at is already powered by the IPCP Pro control processor or by an additional power supply 3 16 5 mm Max Tie drain wires to ground EBP 108 RAAP eBUS Connections Connect up to five eBUS endpoint devices...

Страница 9: ...is receiving power but communication with the control processor is not confirmed Red LED Lights steadily when there is a BUS ID address conflict Green LED Lights steadily when power and communication...

Страница 10: ...gure 1 on page 1 and see Step 5 Cable All Devices on page 7 6 Optional Connect cables to the AAPs Follow the instructions provided with the AAP 7 If you have not already done so set the DIP switches t...

Отзывы: