background image

DVI 201xi Tx • Installation

 

2-13

DDC Switches

When the DVI-D source device boots up, it uses the Display 

Data Channel (DDC), a two-way communication protocol, to 

obtain Extended Display Identification Data (EDID) from the 

display device.  This allows the source to output a resolution 

that matches the capabilities of the display.
A bank of three switches allows the user to determine how the 

source device will obtain the EDID.  The EDID can be obtained 

directly from the display device, or from the internal memory 

within.  The three switches are:

EDID Minder — 

This switch must be On for the EDID Minder 

function to be enabled (see page 3-2).  The factory default for 

this switch is the Off position.

Default EDID —

 When the Default EDID switch 

is On (factory default), an EDID showing a native 

resolution of 1024x768 @ 60 Hz is passed to the 

source device.  The EDID Minder switch must also 

be On for the Default EDID switch to function (see 

the figure at right and page 3-2).

Remote DDC —

 When this switch is Off, DDC will 

be routed to the local monitor.  When the switch is On, the DDC 

is routed to the remote display device.

ON

1   2   3   

ON

OFF

DEF

AUL

T EDID

EDID MINDER

REMOTE DDC

Содержание DVI 201xi TX

Страница 1: ...User s Manual DVI 201xi Tx 68 1645 01 Rev A 12 08 Single Link DVI Transmitter...

Страница 2: ...machen da im Inneren des Geh uses dieses Produktesgef hrlicheSpannungen dienichtisoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das...

Страница 3: ...tection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in ac...

Страница 4: ......

Страница 5: ...see the figure at right The rear panel LED turns amber while the EDID information is read and stored from the local monitor Afterwards the LED turns green e Power off and disconnect the display from t...

Страница 6: ...c Connect a display device to the receiver and if required a local monitor to the transmitter d Connect the transmitter and receiver e Power on the transmitter receiver and display devices f Power on...

Страница 7: ...ections 2 8 DVI D Input 2 8 DVI D Output 2 8 Twisted Pair Output Input 2 10 Terminating shielded cable 2 10 Connections 2 11 Single Link DVI transmission distances 2 12 DDC Switches 2 13 Control Pass...

Страница 8: ...tents cont d Appendix A Reference Information A 1 Specifications A 2 Included Parts A 5 Compatible Receivers A 5 Optional Accessories A 5 68 1645 01 Rev A 12 08 All trademarks mentioned in this manual...

Страница 9: ...DVI 201xi Tx 1 Chapter One Introduction About this Manual About the DVI 201xi Tx DVI 201xi Tx Features...

Страница 10: ...l desktop 12 VDC power supply The receivers listed above have remote power capability and a single power supply connected to either the transmitter or the receiver is able to power both devices Using...

Страница 11: ...display Compact design the transmitter is 1U high a half rack wide and 3 deep for easy rack mounting near the source device Remote powering of transmitter or receiver When the transmitter is connecte...

Страница 12: ...DVI 201xi Tx Introduction Introduction cont d 1 4...

Страница 13: ...DVI 201xi Tx 2 Chapter Two Installation Mounting the DVI 201xi Tx Panel Features Cable Connections...

Страница 14: ...ent temperature Therefore install the equipment in an environment compatible with the maximum ambient temperature Tma 122 F 50 C specified by Extron 2 Reduced air flow Install the equipment in the rac...

Страница 15: ...ollow these instructions 1 Remove rubber feet if these have been installed on the bottom of the unit 2 Align the unit on the shelf and secure it to the shelf with two 4 40 x 3 16 screws in diagonally...

Страница 16: ...he table or other furniture Mark the location of the screw holes of the bracket on the mounting surface 4 Drill four pilot holes each 3 32 2 mm in diameter by 1 4 6 3 mm deep in the mounting surface a...

Страница 17: ...DVI 201xi Tx Installation 2 5...

Страница 18: ...ows the front panel features of the DVI 201xi Tx DVI 201xi Tx DVI TRANSMITTER 1 DVI 201xi Tx front panel features a Power LED An amber light shows when the DVI 201xi Tx is receiving power directly fro...

Страница 19: ...put One female DVI I connector accepts DVI D input from the source device d Local monitor output One female DVI I connector provides DVI D output to the local monitor e EDID Minder Store switch and LE...

Страница 20: ...VI I input connectors are shown in the table on the opposite page DVI D Output Connect the local display device to the female DVI I output on the rear panel of the transmitter and the remote display d...

Страница 21: ...TMDS data 0 TMDS data 2 shield TMDS data 1 shield TMDS data 0 shield TMDS clock shield Pin Pin Signal Signal 2 9 10 17 4 12 20 5 13 21 6 14 22 7 15 23 8 16 24 18 3 11 19 DVI Dual Link Female 1 9 8 17...

Страница 22: ...N Do not use Extron Skew Free Cable with this product 1 Cut the cables to the required length Both cables should be the same length 2 Remove about 7 8 2 2 cm of the outer coat If using STP cable peel...

Страница 23: ...ires into the RJ 45 connector see the figure at right and crimp the cable in the normal manner see the figure below folding the tangs of the connector over the shielded tape Crimped Connector Connecti...

Страница 24: ...at has the same number Transmitter port 1 connects to receiver port 1 Transmitter port 2 connects to receiver port 2 Single Link DVI transmission distances Single Link DVI carries signals at resolutio...

Страница 25: ...ice or from the internal memory within The three switches are EDID Minder This switch must be On for the EDID Minder function to be enabled see page 3 2 The factory default for this switch is the Off...

Страница 26: ...hese signals Use the three pole 3 5 mm captive screw connector on the transmitter to input RS 232 or IR signals from a control device Use the corresponding connector on the receiver to pass signals to...

Страница 27: ...ce to the IR emitter bug that will broadcast the IR signal remotely There are no responses and no requirement for a reverse pathway To connect the control device to the transmitter or the receiver to...

Страница 28: ...WER Power Receptacle DC Power Cord Captive Screw Connector AC Power Cord Ground 12 VDC External Power Supply 12 VDC 1 A Connecting power to DVI DL 201 Tx Rx The ideal length of exposed wire in the str...

Страница 29: ...DVI 201xi Tx 3 Chapter Three Configuration and Operation Configuration Setup and Operation Troubleshooting...

Страница 30: ...itter 4 Set the EDID Minder switch on the transmitter to the On Up position see the figure at right 5 Set the Default EDID switch to the Off Down position see the figure at right 6 Set the Remote DDC...

Страница 31: ...ons equal to or greater than that of the device used to set the EDID Using the EDID Minder with the default EDID 1 Set the EDID Minder switch to the On Up position and the Default EDID switch to the O...

Страница 32: ...cal monitor to the transmitter output 4 Connect the transmitter to the receiver with the two twisted pair cables Transmitter port 1 connects to receiver port 1 Transmitter port 2 connects to receiver...

Страница 33: ...nect the display device to the receiver output and if required the local monitor to the transmitter output 4 Connect the transmitter to the receiver with the two twisted pair cables Transmitter port 1...

Страница 34: ...p the source device Troubleshooting If the DVI 201xi Tx does not provide a high quality output signal check the following possibilities before contacting your Extron representative see back cover for...

Страница 35: ...on it may not be able to send a video signal or the signal may have the wrong resolution or refresh rate Ensure that the DDC are configured correctly for the EDID source see pages 3 2 to 3 5 The sourc...

Страница 36: ...DVI 201xi Tx Configuration and Operation Configuration and Operation cont d 3 8...

Страница 37: ...DVI 201xi Tx A Appendix A Reference Information Specifications Included Parts Optional Accessories...

Страница 38: ...Connectors 2 RJ 45 per unit for 2 CAT 5 5e 6 7 or STP shielded twisted pair cables connecting the transmitter and receiver Termination standards TIA EIA T568A or T568B Pin configurations for each stan...

Страница 39: ...the transmitter and the receiver Serial control pin configurations Captive screw connectors 1 TX 2 RX 3 GND General External power supply 100 VAC to 240 VAC 50 60 Hz 6 W max external to 12 VDC 2 A re...

Страница 40: ...2 01 Enclosure type Metal Enclosure dimensions 1 75 H x 8 75 W x 3 0 D 1U high half rack wide 4 4 cm H x 22 2 cm W x 7 6 cm D Depth excludes connectors Product weight Transmitter 0 6 lbs 0 3 kg Shippi...

Страница 41: ...number DVI 201 Rx 60 734 13 HDMI 201 Rx 60 806 13 DVI 201 AD Rx 60 865 2x HDMI 201 AD Rx 60 864 2x DVI DL 201 Rx single link mode only 60 957 13 Optional Accessories Accessory Part number RSF 123 3 5...

Страница 42: ...DVI 201xi Tx Reference Information Reference Information cont d A 6...

Страница 43: ...bai This Limited Warranty does not apply if the fault has been caused by misuse improper handling care electrical or mechanical abuse abnormal operating conditions or non Extron authorized modificatio...

Страница 44: ...SA Canada Only 1 919 863 1794 1 919 863 1797 FAX Extron Europe 800 3987 6673 Inside Europe Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 F...

Отзывы: