background image

 

 

About the DMS 1600 and DMS 3600

The

 

DMS

 

1600

 

and

 

DMS

 

3600

 (figure 

1

are

 configurable 

matrix

 

switchers

 

that

 

distribute

 

DVI

 

signals.

 

I/O

 

boards

 

route

 

signals

 

that

 

are

 

compatible

 

with

 

all

 

Extron

 

DVI

 

video

 

product

 

lines.

 

The

 

matrix

 

switcher

 

routes

 

an

input

 

signal

 

to

 

an

combination

 

of

 

outputs.

 

The

 

matrix

 

switcher

 

can

 

route

 

multiple

 

input/output

 configurations 

simultaneousl

y

.

AUDIO

DVI-D INPUT

FOXBOX 4G Tx DVI

RS-232

OVER FIBER ALARM

Tx Rx

1    2

12V         
1.0A MAX

POWER

AUDIO

DVI-D OUTPUT

FOXBOX 4G Rx DVI

RS-232

OVER FIBER ALARM

Tx Rx

1    2

12V         
1.0A MAX

POWER

MODE

AUDIO

DVI-D OUTPUT

FOXBOX 4G Rx DVI

RS-232

OVER FIBER ALARM

Tx Rx

1    2

12V         
1.0A MAX

POWER

MODE

1

ON

2

AUDIO

DVI-D INPUT

FOXBOX 4G Tx DVI

RS-232

OVER FIBER ALARM

Tx Rx

1    2

12V         
1.0A MAX

POWER

MODE

1

ON

2

ANAHEIM, CA

RESET

RS232/RS422

REMOTE

LAN

ACT LINK

100-240V      

50/60Hz

1.2A MAX.

100-240V      

50/60Hz

1.2A MAX.

REDUNDANT

PRIMARY

DISCONNECT BOTH POWER
CORDS BEFORE SERVICING

1 - 4

5 - 8

9 - 12

13- 16

17 - 20

21 - 24

25 - 28

29- 32

33 - 36

FAN ASSEMBLY

FAN ASSEMBLY

PRIMARY POWER SUPPLY

REDUNDANT POWER SUPPLY

DVI-D OUTPUTS

A

B

C

D

DVI-D OUTPUTS

A

B

C

D

DVI-D OUTPUTS

A

B

C

D

DVI-D OUTPUTS

A

B

C

D

DVI-D OUTPUTS

A

B

C

D

A

B

DVI-D INPUTS

DVI-D OUTPUTS

C

D

A

B

C

D

A

B

DVI-D INPUTS

DVI-D OUTPUTS

C

D

A

B

C

D

A

B

DVI-D INPUTS

DVI-D OUTPUTS

C

D

A

B

C

D

A

B

DVI-D INPUTS

DVI-D OUTPUTS

C

D

A

B

C

D

UPS 507

UNVERSAL SIGNAL PROCESSOR

ADJUST

DETAIL

ZOOM

/PAN

BRIGHT
/CONT

COLOR

/TINT

SIZE

POSITION

MUTE

FREEZE

AUTO
IMAGE

PIP

PRESET

6

7

5

4

3

2

1

MENU

NEXT

INPUTS

CONFIG

HD Camera

FOXBOX 4G Tx DVI

FOXBOX 4G Rx DVI

USP 507

PC

Extron

DMS 3600

Modular DVI Matrix Switcher

Digital Monitors

DVI Projectors

HDTV Monitors

Analog Monitor

DVI Equipped

PCs

Compact HDTV

Camera Systems

Figure 1. 

Typical DMS 1600 Application

The

 

matrix

 

switcher

 

can

 

be

 

remotel

controlled

 

via

 

its

 

Ethernet

 

LAN

 

port,

 

a

 

serial

 

port,

 

or

 

a

 

USB

 

port

 

using

 

either

 

the

 

Windows-based

 

Extron

 

Matrix

 

Switchers

 

Control

 

Program

 

or

 

the

 

SIS.

The

 

switcher

 

has

 

two

 

internal,

 

hot-swappable

 

100

 

VAC

 

to

 

240

 

VAC,

 

50-60

 

Hz,

 

175-watt

 

power

 

supplies

 

that

 

provide

 

worldwide

 

power

 

compatibilit

and

 

reliabilit

y

.

Configurability

The

 

DMS

 

1600

 

and

 

DMS

 

3600

 

are

 

assembled

 

from

 

individual

 

input/

output

 

(I/O

boards.

 

The

 

switcher

 

can

 

include

 

up

 

to

 

four

 

(DMS

 

1600

or

 

nine

 

(DMS

 

3600

I/O

 

boards.

 

There

 

are

 

three

 

t

y

pes

 

of

 

I/O

 

boards

 

available:

• 

4x4

 

DVI

 

input

 

and

 

output

 

board

• 

4

 

DVI

 

input

 

board

• 

4

 

DVI

 

output

 

board

B

adding

 

or

 

removing

 

I/O

 

boards

 

within

 

certain

 

rules

 

that

 

are

 

detailed

 

in

 

the

 

NOTE

 

below,

 y

ou

 

can

 

expand

 

and

 

contract

 

the

 

DMS

 

1600

 

and

 

DMS

 

3600

 

from

 

a

 

4-input

 

b

4-output

 

matrix

 

to

 

up

 

to

 

either:

• 

DMS Matrix 1600 —

 

A

 

16-input

 

b

16-output

 

matrix

• 

DMS Matrix 3600 —

 

A

 

36-input

 

b

36-output

 

matrix

NOTE:

 

There

 

are

 

certain

 

rules

 

for

 configuring 

the

 

DMS

 

matrix

 

switcher

 

for

 

proper

 

operation,

 

as

 

detailed

 

below:

• 

The

 

top

 

slot

 

(slot

 

1

MUST

 

contain

 

a

 

4x4

 

DVI

 

input

 

and

 

output

 

board.

• 

The

 

next

 

slot

 

(slot

 

2

can

 

contain

 

an

of

 

the

 

three

 

board

 

t

y

pes

 

(a

 

4x4

 

DVI

 

input

 

and

 

output

 

board,

 

4

 

DVI

 

input

 

board,

 

or

 

4

 

DVI

 

output

 

board

)

.

• 

A

 

4x4

 

DVI

 

input

 

and

 

output

 

board

 

can

 

be

 

followed

 

(in

 

the

 

slot

 

directl

underneath

 

it

b

an

of

 

the

 

board

 

t

y

pes.

• 

After

 y

ou

 

insert

 

a

 

4

 

DVI

 

input

 

board

 

or

 

4

 

DVI

 

output

 

board,

 

all

 

active

 

boards

 

underneath

 

it

 

MUST

 

be

 

the

 

same

 

t

y

pe.

• 

If

 y

ou

 

install

 

a

 

blank

 

panel,

 

all

 

slots

 

under

 

it

 

MUST

 

contain

 

blank

 

panels

 

(

y

ou

 

cannot

 

skip

 

a

 

slot

)

.

2

DMS 1600 and DMS 3600 • Introduction

DMS 1600 and DMS 3600 • Introduction

3

Содержание DMS 1600

Страница 1: ...side USA and Canada Only 1 919 863 1794 1 919 863 1797 FAX Extron Europe 800 3987 6673 Inside Europe Only 31 33 453 4040 31 33 453 4050 FAX Extron Asia 800 7339 8766 Inside Asia Only 65 6383 4400 65 6383 4664 FAX Extron Japan 81 3 3511 7655 81 3 3511 7656 FAX Extron China 400 883 1568 Inside China Only 86 21 3760 1568 86 21 3760 1566 FAX Extron Middle East 971 4 2991800 971 4 2991880 FAX 2010 Extr...

Страница 2: ...léctrica indicada en el mismo La alimentación eléctrica de este equipo debe provenir de un sistema de distribución general con conductor neutro a tierra La tercera pata puesta a tierra es una medida de seguridad no puentearia ni eliminaria Desconexión de alimentación eléctrica Para desconectar con seguridad la acometida de alimentación eléctrica al equipo desenchufar todos los cables de alimentaci...

Страница 3: ...anel Operation is subject to the following two conditions 1 this device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation The Class A limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates u...

Страница 4: ...ing a Network Ethernet Connection 11 Establishing a USB Port Connection 12 Host to Switcher instructions 13 Command Response Table for SIS Commands 14 Installing and Starting the Control Program 18 Installing the Program 18 First time Connection Considerations 19 Starting the Program 20 Accessing the HTML Pages 22 Configuring for Network Communication 22 Loading the Start up Page 23 Maintenance an...

Страница 5: ...chers unless a significant difference is noted in their features or operation This setup guide helps you to easily and quickly set up and configure your Extron DMS 1600 and DMS 3600 switcher Step by step instructions show you how to Connect the hardware Perform basic operations Use both the front panel controls and selected Simple Instruction Set SIS commands Load and start the Windows based Matri...

Страница 6: ...atrix Switcher Digital Monitors DVI Projectors HDTV Monitors Analog Monitor DVI Equipped PCs Compact HDTV Camera Systems Figure 1 Typical DMS 1600 Application The matrix switcher can be remotely controlled via its Ethernet LAN port a serial port or a USB port using either the Windows based Extron Matrix Switchers Control Program or the SIS The switcher has two internal hot swappable 100 VAC to 240...

Страница 7: ...NPUTS A B DVI D INPUTS DV C D A B Slot 1 1 4 Input 1 Slot 2 5 8 Slot 3 No board installed Slot 4 No board installed Output 1 Input 3 Input 4 Input 2 Output 2 Input 5 Input 6 Input 7 Input 8 Location A Input Location A Output Figure 2 Arrangement of Inputs and Outputs on the I O boards The board position designators correspond to the input and output numbers served by that position 1 through 4 5 th...

Страница 8: ...ction Wire as a patch straight through cable Computer or control system connection Wire the interface cable as a crossover cable NOTE The factory default IP address is 192 168 254 254 e Reset button Initiates four levels of reset of the matrix switcher For different reset levels press and hold the button while the switcher is running or while you power up the switcher Refer to the DMS 1600 and DMS...

Страница 9: ...he Esc button to clear any input button output button or control button indicators that may be lit 2 Press and release the desired input button 5 The button lights to indicate the selection 3 Press and release the desired output buttons 3 4 ENTER 8 The output buttons blink to indicate the potential ties The Enter button blinks to indicate the need to confirm the change 4 Press and release the Ente...

Страница 10: ...cessary enter the appropriate password If the password is accepted the switcher responds with Login User or Login Administrator If the password is not accepted the Password prompt reappears Saving or Recalling a Preset 1 Save a preset Press and hold the Preset button until it flashes PRESET PRESET The Preset button blinks Press and hold 2 seconds Save a preset Recall a preset Press and release the...

Страница 11: ...verbose mode SIS command In verbose mode 3 the Telnet socket reports changes using messages that resemble SIS command responses Establishing a USB Port Connection A standard USB cable and the Extron DataViewer utility version 2 0 or newer can be used for connection to the DMS switcher Configuration port The USB cable available at any local electronics store should be terminated on one end with a m...

Страница 12: ... configuration 00 untied X Output number 01 maximum number of outputs for your configuration Command ASCII Command host to unit Response unit to host Additional description Channel mute commands Channel mute X 1B VmtX 1 Mute output X no signal is output Channel unmute X 0B VmtX 0 Unmute output X signal is output Read channel mute X B X 1 mute on 0 mute off Global channel mute 1 B Vmt1 Mute all out...

Страница 13: ...0 outputs C1 4 inputs by 4 outputs C3 0 inputs by 4 outputs X Part number 60 nnnn nn X Firmware version number to second decimal place x xx NOTE X1 IP address nnn nnn nnn nnn X1 DHCP 0 1 off 1 on X1 Verbose mode 0 clear or none default for Telnet connection 1 verbose mode default for RS 232 RS 422 connection 2 tagged responses for queries 3 verbose mode and tagged for queries X1 Port timeout inter...

Страница 14: ... program creates a C Program Files Extron Matrix_Switchers directory and an Extron Electronics Matrix Switchers group folder It installs the following four programs MATRIX Switcher Control Program MATRIX Switcher Help Uninstall MATRIX Switcher Check for Matrix Updates First time Connection Considerations LAN port connection If you connect your PC to the switcher via the LAN port and it is the firs...

Страница 15: ...E For a comm port check the baud rate displayed in the Comm Port Selection window If you need to change the baud rate click the Baud button and double click the desired baud rate Click OK If you selected a serial port or the USB port in step 2 the Matrix Switchers Control Program is ready for operation 3 If you selected IP LAN in step 2 the IP Connection window appears a Examine the Matrix IP Addr...

Страница 16: ...new IP address for the unit obtained in step 1 and the MAC address of the unit from the rear panel of the unit For example arp s 10 13 197 7 00 05 A6 03 69 B0 and then press Enter After receiving the arp s command the controller changes to the new address and starts responding to the ping requests as described in step 5 NOTE You must ping the DMS matrix switcher as shown in step 5 for the IP addre...

Страница 17: ...ng a Power Supply Module Removing and Installing a Fan Removing and Installing an I O Board or Blank Panel Circuit boards can be added or removed to increase or decrease the I O configuration size of the switcher NOTES For proper cooling and air flow boards or blank panels should be installed in all locations during normal switcher operations See A Note on I O Boards to understand the different ar...

Страница 18: ...emoving and Installing a Power Supply Module The two power supply modules primary power supply and redundant power supply are identical and hot swappable Each power supply module has a 2 color LED visible on the rear panel that indicates the status of the power supply outputs If the LED is lit green the power supply is operating normally If the LED is lit red the supply has failed and should be re...

Страница 19: ...EVEL ACT LINK 100 24 0V 50 60H z 1 2 A MA X 100 24 0V 50 60H z 1 2 A MA X REDUNDANT PRIMARY DISCONNECT BOTH POWER CORDS BEFORE SERVICING SW ITC H RE FER EN CE PR IM AR Y PO WE R SU PP LY RE DU ND AN T PO WE R SU PP LY AN AH EIM CA 1 8 9 16 17 24 25 32 Knurled Knobs A B DV I D INP UT S DV I D OU TP UT S DM S 44 DV I C D A B C D A B DV I D INP UT S DV I D OU TP UT S DM S 44 DV I C D A B C D A B DV I...

Страница 20: ...30 DMS 1600 and DMS 3600 Maintenance and Modifications ...

Страница 21: ......

Отзывы: