18
CrossPoint / MAV Matrix Switchers • Remote Control
Command
SIS command
(host to switcher)
Response
(switcher to host)
Aditional information
Audio output volume
Set the audio volume to a specific value
X@
*
X%
V
Out
X@
•Vol
X%]
Example:
1*50v
Out01•Vol50
]
Set output 1 volume to a value of
50
(79% of max
volume, 14 dB of attenuation).
Incr
ement volume
X@
+V
Out
X@
•Vol
X%]
Incr
ease volume by 1 step.
Example:
1+V
Out01•Vol51
]
Decr
ement volume
X@
-V
Out
X@
•Vol
X%]
Decr
ease volume by 1 step.
Read output volume
X@
V
X%]
Save and r
ecall pr
esets
NOTES:
•
If you try to r
ecall a pr
eset that is not saved, the matrix switcher r
esponds with the err
or code E11.
•
The following characters ar
e invalid in pr
eset names: + - , ` @ = [ ] { } ‘ “ ; : | \ and ?.
Save curr
ent configuration as a global pr
eset
X^
,
Spr
X^]
Command character is a comma.
Example:
9
,
Spr09
]
Save curr
ent ties as pr
eset 9.
Recall a global pr
eset
X^
.
Rpr
X^]
Command character is a period.
Example:
5
.
Rpr05
]
Recall pr
eset 5, which becomes the curr
ent
configuration.
KEY
:
X@
= Output number
01
– (maximum number of outputs for your model)
X%
= V
olume
0
–
64
(1 dB/step except for 0-to-1, which is 22 dB) (default =
64
[0 dB])
X^
= Pr
eset number
00
–
32
(
00
= curr
ent configuration)