Hardware status
—
Provides an overall view of the status of the matrix switcher,
including the power supply voltages, the temperature status, the Remote
RS-232/RS-422 port configuration, and the installed and updated firmware
status (figure 5-16).
Green — Proper operation.
Red — Component has failed.
White — Component is not installed.
Figure 5-16 — Status window
Name presets
—
Allows you to assign a name to each of the 64 global memory
presets and 100 room presets.
N
Preset names are limited to 12 upper- and lower-case alphanumeric characters,
space, and the _ and / characters.
N
The following characters are invalid in preset names:
+ ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
Show RS-232 Strings
—
Displays the ASCII commands that are used by the
current configuration. You can refer to these for SIS programming.
I/O group settings
—
Allows you to establish I/O groups.
Room configuration
—
Allows you to assign outputs to rooms or delete outputs
from rooms.
N
A Room is a subset of outputs that are logically related to each other, as
determined by the operator. The matrix switcher supports up to 10 rooms, each
of which can consist of from 1 to 16 outputs.
Initialize
—
Initializes and clears any or all of the following: ties, presets, preset
names, icon names, and icons.
Содержание CrossPoint 450 Plus 3248 HV
Страница 1: ...CrossPoint 450 Plus Series MAV Plus series Large Scale Matrix Switchers 68 521 03 Rev B 11 09 ...
Страница 4: ......
Страница 10: ...Table of Contents cont d CrossPoint 450 Plus and MAV Plus Switchers Table of Contents vi ...
Страница 32: ...Installation cont d CrossPoint 450 Plus and MAV Plus Switchers Installation 2 14 ...
Страница 86: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 54 ...
Страница 88: ...Operation cont d CrossPoint 450 Plus and MAV Plus Switchers Operation 3 56 ...
Страница 112: ...Programmer s Guide cont d CrossPoint 450 Plus and MAV Plus Switchers Programmer s Guide 4 24 ...
Страница 161: ...CrossPoint 450 Plus and MAV Plus Switchers A Appendix A Ethernet Connection Ethernet Link Subnetting A Primer ...
Страница 183: ...B 15 CrossPoint 450 Plus and MAV Plus Switchers Reference Information Button label blanks ...
Страница 184: ...Reference Information cont d CrossPoint 450 Plus and MAV Plus Switchers Reference Information B 16 ...