Programmer’s Guide, cont’d
CrossPoint 300 Matrix Switchers • Programmer’s Guide
4-6
Command/Response Table for SIS Commands
Symbol Definitions:
= Carriage return/line feed
= Carriage return (no line feed)
•
= Space
Esc
= Escape key
Input and output numbers in commands may be entered as either 1-digit, 2-digit, or 3-digit
numbers. All input and output numbers are reported as 2-digit numbers in the response.
X1
= Input number
01 – 08
(CrossPoint 300 84/88/816);
01 – 12
(CrossPoint 300 124/128);
01 – 16
(CrossPoint 300 168/1616)
X2
= Input number (for tie)
0 – maximum number of inputs (0 = disconnected)
X3
= Output number
01 – 04
(CrossPoint 300 84/124);
01 – 08
(CrossPoint 300 88/128/168);
01 – 12
(CrossPoint 300 1212);
01 – 16
(CrossPoint 300 816/1616)
X4
= Mute, Lock mode, power supply
(0 = off/mode 0/not OK, 1 = on/mode 1/OK, 2 = mode 2)
X5
= Numeric dB value
–18 to +24 (45 steps of gain or attenuation)
X6
= Audio gain
0 – 24 (1 dB/step) (default = 0 dB)
X7
= Audio attenuation
1 – 18 (1 dB/step)
X8
= Volume adjustment range
0 – 64 (1 dB/step except for 0-to-1, which is 22 dB)
(default = 64 [0 dB])
X9
= Global preset #
0 – 32 (0 = current configuration)
X10
= Video/audio mute
0 = no mutes
2 = audio mute
1 = video mute
3 = video and audio mute
X11
= Firmware version number to the
second decimal place (x.xx)
X12
= Verbose firmware version-description-upload date/time.
See the Query software version (verbose) command on page 4-12.
X13
= Name
12 characters maximum for global preset names.
Upper- and lower-case alphanumeric characters and
_ / and spaces are valid.
The following characters are invalid in the name: + ~ , @ = ‘ [ ] { } < > ’ “ ; : | \ and ?.
X14
= Baud rate
9600, 19200, 38400, 115200
X15
= Parity
O
dd, even, none, mark, space (only the first letter is
required)
X16
= Data bits
7, 8
X17
= Stop bits
1, 2
X18
= Port type
0 = RS-232, 1 = RS-422
X19
= Voltage
Positive or negative voltage magnitude
X20
= Temperature
Degrees Fahrenheit
Содержание CrossPoint 300 1212
Страница 1: ...CrossPoint 300 Series Matrix Switchers 68 521 10 Rev B 03 07 ...
Страница 14: ...Introduction cont d CrossPoint 300 Matrix Switchers Introduction 1 6 This page was intentionally left blank ...
Страница 24: ...Installation cont d CrossPoint 300 Matrix Switchers Installation 2 10 ...
Страница 70: ...Operation cont d CrossPoint 300 Matrix Switchers Operation 3 46 This page was intentionally left blank ...
Страница 95: ...CrossPoint 300 Matrix Switchers A Appendix A Reference Information Specifications Part Numbers Button Labels ...
Страница 101: ...A 7 CrossPoint 300 Matrix Switchers Reference Information Figure A 1 Button label blanks 16 button strips ...
Страница 102: ...Reference Information cont d CrossPoint 300 Matrix Switchers Reference Information A 8 ...