Step 8: Mounting the ACP 105 D

Prior to mounting:

1. 

Feed all device cables through the wall or furniture.

NOTE:

  If the unit is not installed in a mud ring, the plastic spacer must be installed. The spacer positions the unit to allow 

the plastic faceplate to attach properly and securely.

2. 

Ensure the cables are connected to the ACP 105 D rear panel.

To mount an ACP 105 D with a wall mounting bracket (mud 
ring):

1. 

Mark the position of the hole for the wallplate on desired 
wall location. Use a level to ensure the hole is marked at the 
correct angle. 

2. 

Use a drywall saw to cut the hole for the wallplate (see 

1

 in 

the figure to the right).

3. 

Insert the mounting bracket (mud ring) into the hole and use 
a screw driver to turn and tighten the locking arms until they 
clamp the mud ring to the mounting surface (

2

). Do not 

overtighten.

4. 

If not already done, set bus ID DIP switches so the panel has a 
unique bus ID (

3

).

5. 

Use the two provided screws to secure the metal mounting 
plate to the mud ring (

4

).

6. 

Use the other two provided screws to secure the plastic 
faceplate to the metal mounting plate (

5

).

To mount an ACP 105 D with a junction box:

1. 

Install the junction box following the instructions provided with 
the chosen junction box. No junction box is included with the 
ACP 105 D.

2. 

Locate a suitable wall stud and mark the location of the hole on 
the wall. Use a level to ensure the hole is marked at the correct 
angle.

3. 

Use a drywall saw to cut the hole. Follow the instructions of 
the junction box manufacturer for the correct dimensions of the 
hole. Use at least two screws or nails to secure the box to the 
wall or stud. Follow steps 4 through 6 above to complete the 
installation.

Wall

Wall Mounting

Bracket

Faceplate

ACP 105 D

SO

URCE

 1

SO

URC

E 2

SO

URCE 

3

SOU

RCE 

5

SOU

RCE 

4

1

1

2

2

3

3

4

4

5

5

Electrical
Junction 
Box

ACP 105 D

3

3

4

4

SO

URCE 

1

SOUR

CE 

2

SOUR

CE 

3

SO

URCE 

5

SO

URCE 

4

Faceplate

5

5

Содержание ACP 105 D

Страница 1: ...ounting see the ACP 105 D product page at www extron com for more information regarding the ACP 105 D SOURCE 1 SOURCE 2 V ACP PWR LOAD 1 5W S S G V S S G STATUS GREEN AMBER RED LINK COM ERROR ID ERROR SOURCE 3 SOURCE 4 SOURCE 5 A A B B C C D D E E Figure 1 ACP 105 D A Front Panel Selector Buttons D Reset Button B ACP Ports 2 E Bus ID DIP Switches C Connection Status LED Installation Step 1 Get Rea...

Страница 2: ...th the ACP 105 D Americans with Disabilities Act ADA Compliance When planning where to install these devices consider factors affecting accessibility of the button panel such as height from the floor distance from obstructions and how far a user must reach to press the buttons For guidelines see sections 307 Protruding Objects and 308 Reach Ranges of the 2010 ADA Standards for Accessible Design av...

Страница 3: ...nflicts may cause one or more of the panels to not be recognized in DSP Configurator or by the host device Up to eight ACP devices can be connected in the same system V G S S V G S S ACP PWR LOAD 1 5W STATUS GREEN AMBER RED LINK COM ERROR ID ERROR V S G S 0 1 0 0 1 0 ON 1 2 3 4 5 6 0 0 0 0 0 1 1 ON 1 2 3 4 5 6 18 Unit address DIP switches Binary address ACP port on a DMP 128 Plus or on another ACP...

Страница 4: ...captive screw connector to each end of the cable wiring both ends the same In most cases ACP devices are powered by the host device Power is carried on the V pin of the ACP 105 D and other ACP devices Extron STP20 2 1000 or STP20 2P 100 cable is recommended for ACP device connections ACP devices that are relatively far from the host device can be connected to an optional Extron PS 1220EB eBUS powe...

Страница 5: ... Canadian Electrical Code part 1 section 16 The power supply shall not be permanently fixed to building structure or similar structure L installation doit toujours être conforme aux dispositions applicables du Code américain de l électricité National Electrical Code ANSI NFPA 70 article 725 et du Code canadien de l électricité partie 1 section 16 La source d alimentation ne devra pas être fixée de...

Страница 6: ...iguration file to the device Step 7 Test and Troubleshoot 1 Verify the ACP bus ID DIP switches are set to the desired address on each unit and that there are no bus ID address conflicts in the system As mentioned in the rear panel features diagram in step 4 see page 3 the ACP LED lights green when power and communication are present and there are no bus ID address conflicts Refer to the legend on ...

Страница 7: ...ne set bus ID DIP switches so the panel has a unique bus ID 3 5 Use the two provided screws to secure the metal mounting plate to the mud ring 4 6 Use the other two provided screws to secure the plastic faceplate to the metal mounting plate 5 To mount an ACP 105 D with a junction box 1 Install the junction box following the instructions provided with the chosen junction box No junction box is incl...

Страница 8: ...bility and related topics see the Extron Safety and Regulatory Compliance Guide on the Extron website 2019 Extron Electronics All rights reserved www extron com All trademarks mentioned are the property of their respective owners Worldwide Headquarters Extron USA West 1025 E Ball Road Anaheim CA 92805 800 633 9876 ...

Отзывы: