The Extron ACP 105 D Audio Control Panel is a fully configurable control interface for use with any Extron ACP-enabled device.
Each ACP 105 D includes two ACP ports, which support power and communication between the host device and the ACP 105 D. 
Up to eight ACP panels can be used per host device for more demanding control needs.

Planning System Installation

When planning an ACP system installation, consider how many ACP panels to use, maximum cable distance, and mounting (see 
the ACP 105 D product page at 

www.extron.com

 for more information regarding the ACP 105 D).

SOURCE 1

SOURCE 2

+V

AC

P

PWR LOAD = 1.5W

+S

-S

G

+V

+S

-S

G

ST

AT

US

GREEN AMBER

RED

LINK COM ERRO

R

ID ERRO

R

SOURCE 3

SOURCE 4

SOURCE 5

A

A

B

B

C

C

D

D

E

E

Figure 1. 

ACP 105 D

A

 

Front Panel Selector Buttons

D

 

Reset Button

B

 

ACP Ports (2)

E

 

Bus ID DIP Switches

C

 

Connection Status LED

Installation

Step 1: Get Ready

Use the following checklist to prepare for installation:

 

…

Download and install the latest software, firmware, and device drivers needed to connect to the host device and  
configure the connected ACP devices (see the host device user guide, available at 

www.extron.com

, for details  

regarding software and drivers).

 

…

Obtain cables, mounting hardware, and any other supplies required for the installation.

Содержание ACP 105 D

Страница 1: ...ounting see the ACP 105 D product page at www extron com for more information regarding the ACP 105 D SOURCE 1 SOURCE 2 V ACP PWR LOAD 1 5W S S G V S S G STATUS GREEN AMBER RED LINK COM ERROR ID ERROR SOURCE 3 SOURCE 4 SOURCE 5 A A B B C C D D E E Figure 1 ACP 105 D A Front Panel Selector Buttons D Reset Button B ACP Ports 2 E Bus ID DIP Switches C Connection Status LED Installation Step 1 Get Rea...

Страница 2: ...th the ACP 105 D Americans with Disabilities Act ADA Compliance When planning where to install these devices consider factors affecting accessibility of the button panel such as height from the floor distance from obstructions and how far a user must reach to press the buttons For guidelines see sections 307 Protruding Objects and 308 Reach Ranges of the 2010 ADA Standards for Accessible Design av...

Страница 3: ...nflicts may cause one or more of the panels to not be recognized in DSP Configurator or by the host device Up to eight ACP devices can be connected in the same system V G S S V G S S ACP PWR LOAD 1 5W STATUS GREEN AMBER RED LINK COM ERROR ID ERROR V S G S 0 1 0 0 1 0 ON 1 2 3 4 5 6 0 0 0 0 0 1 1 ON 1 2 3 4 5 6 18 Unit address DIP switches Binary address ACP port on a DMP 128 Plus or on another ACP...

Страница 4: ...captive screw connector to each end of the cable wiring both ends the same In most cases ACP devices are powered by the host device Power is carried on the V pin of the ACP 105 D and other ACP devices Extron STP20 2 1000 or STP20 2P 100 cable is recommended for ACP device connections ACP devices that are relatively far from the host device can be connected to an optional Extron PS 1220EB eBUS powe...

Страница 5: ... Canadian Electrical Code part 1 section 16 The power supply shall not be permanently fixed to building structure or similar structure L installation doit toujours être conforme aux dispositions applicables du Code américain de l électricité National Electrical Code ANSI NFPA 70 article 725 et du Code canadien de l électricité partie 1 section 16 La source d alimentation ne devra pas être fixée de...

Страница 6: ...iguration file to the device Step 7 Test and Troubleshoot 1 Verify the ACP bus ID DIP switches are set to the desired address on each unit and that there are no bus ID address conflicts in the system As mentioned in the rear panel features diagram in step 4 see page 3 the ACP LED lights green when power and communication are present and there are no bus ID address conflicts Refer to the legend on ...

Страница 7: ...ne set bus ID DIP switches so the panel has a unique bus ID 3 5 Use the two provided screws to secure the metal mounting plate to the mud ring 4 6 Use the other two provided screws to secure the plastic faceplate to the metal mounting plate 5 To mount an ACP 105 D with a junction box 1 Install the junction box following the instructions provided with the chosen junction box No junction box is incl...

Страница 8: ...bility and related topics see the Extron Safety and Regulatory Compliance Guide on the Extron website 2019 Extron Electronics All rights reserved www extron com All trademarks mentioned are the property of their respective owners Worldwide Headquarters Extron USA West 1025 E Ball Road Anaheim CA 92805 800 633 9876 ...

Отзывы: