background image

 

MTP 4T 15HD RS • Introduction

3

Twisted Pair (TP) Cable Advantages

Twisted pair cable is much smaller, lighter, more flexible, and less expensive than coaxial 
cable.  These TP products make cable runs simpler and less cumbersome.  Termination of the 

cable with RJ-45 connectors is simple, quick, and economical.

Transmission Distance

• 

The maximum distance is determined by the frequency and resolution of the signal 
that is input to the transmitter.  The table below specifies the recommended maximum 
transmission distances and transmitter Pre-Peak switch positions (see item 

e

 on  

page 7

) using Extron Enhanced Skew-Free AV UTP cable or UTP CAT 5, 5e, or 6 cable, 

terminated with RJ-45 connectors.

Recommended transmission distances at 60 Hz

Video 
Format

Pre-Peak 
off

Pre-Peak 
on

Max. distance 
(high quality)

Max. distance 
(variable quality)

Composite, 
S-video, 
Component

800 ft. 

(245 m)

1000 ft.

(300 m)

640 x 480

<300 ft. 

(90 m)

<350 ft. 

(105 m)

700 ft. 

(215 m)

750 ft.

(240 m)

800 x 600

<300 ft. 

(90 m)

<350 ft.

(105 m)

550 ft.

(165 m)

650 ft.

(200 m)

1024 x 768

<300 ft.

(90 m)

<350 ft.

(105 m)

500 ft.

(150 m)

600 ft.

(185 m)

1280 x 1024

<250 ft. 

(75 m)

<300 ft.

(90 m)

350 ft.

(105 m)

450 ft..

(135 m)

1600 x 1200

<250 ft.

(75 m)

<300 ft.

(90 m)

300 ft.

(90 m)

450 ft.

(135 m)

NOTE:

   It is possible to exceed the recommended distance; however, image quality may 

be reduced.

NOTE:

   The MTP units are designed for and perform best with Extron Enhanced Skew 

Free AV cable terminated in accordance with the TIA/EIA T 568 A wiring 
standard.  CAT 5, 5e, and 6 cables are acceptable, but less preferable.  Extron 

also recommends the use of preterminated and tested cables.  Cables terminated 
on site should be tested before use to ensure that they comply with Category 5 
specifications.

NOTES:

  

  The recommendations shown in the table above apply for a single transmitter 

and receiver and for a transmission daisy chain.  For example, the maximum 

suggested range for 1024 x 768 video is 300 ft. (90 m) with Pre-Peak off 

and 500 ft. (150 m) with Pre-Peak on whether the system consists of one 
transmitter and one receiver or a transmitter and three daisy-chained receivers.

• 

For a daisy-chained system, the first receiver in the chain must be at least  
100 ft. (30 m) from the transmitter when the Pre-Peak switch is on.

• 

For a daisy-chained system, any receiver in the chain closer than 350 ft.  
(105 m) may experience some form of over-peaking when the Pre-Peak switch 
is on.  An overpeaked image may appear bloomed.

Содержание A/V Receiver MTP 4T 15HD RS

Страница 1: ...User Guide MTP 4T 15HD RS Twisted Pair Quad MTP Twisted Pair Transmitter for VGA and RS 232 68 1398 01 Rev B 05 12...

Страница 2: ...Produktes gef hrliche Spannungen die nicht isoliert sind und die einen elektrischen Schock verursachen k nnen herrschen Achtung Lesen der Anleitungen Bevor Sie das Ger t zum ersten Mal verwenden soll...

Страница 3: ...a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to...

Страница 4: ...ention to important information TIP A tip provides a suggestion to make working with the application easier WARNING A warning warns of things or actions that might cause injury death or other severe c...

Страница 5: ...ion 4 Installation 4 Tabletop Placement 4 Rack Mounting 4 UL Requirements 4 Installation Instructions 5 Connections and Settings 6 TP cable Termination 7 Receiver Considerations 8 Front Panel Controls...

Страница 6: ...15HD RS can support four transmitter receiver systems Each system requires a transmitter and at least one connected compatible MTP receiver Additional receivers can be daisy chained NOTE In this manua...

Страница 7: ...e connected in series to a single transmitter provided that the total distance from the transmitter s TP output to the last receiver in the chain does not exceed the recommended distance for the resol...

Страница 8: ...t 90 m 350 ft 105 m 450 ft 135 m 1600 x 1200 250 ft 75 m 300 ft 90 m 300 ft 90 m 450 ft 135 m NOTE It is possible to exceed the recommended distance however image quality may be reduced NOTE The MTP u...

Страница 9: ...ent temperature of the rack environment may be greater than room ambient temperature Therefore consider installing the equipment in an environment compatible with the maximum 122 F 50 C ambient temper...

Страница 10: ...them 2 Attach the included rack through desk mounting brackets part number 70 077 03 to the unit using eight machine screws supplied with the mounting kit Optional Rack Mounting Bracket Figure 1 Attac...

Страница 11: ...R return pins pins 1 and 6 G Y and G return pins pins 2 and 7 and B B Y and B return pins pins 3 and 8 For S video use the R R return C chroma G and G return Y luma pins For composite video use the G...

Страница 12: ...cable NOTE If you are using Enhanced Skew Free AV cable use the TIA EIA T568A standard only Figure 4 TP Cable Termination NOTE Enhanced Skew free AV cable is not recommended for Ethernet LAN applicati...

Страница 13: ...0 ft with Pre Peak on for either one transmitter and one receiver or a transmitter and three daisy chained receivers For daisy chained units the first receiver in the chain must be at least 100 ft fro...

Страница 14: ...ser Guide for details Non SEQ Receiver Skew Compensation Try using the following methods to minimize or eliminate pair skew Switch to the Extron Enhanced Skew Free AV UTP cable Add a skew compensation...

Страница 15: ...i level or tri level for component video Output type receivers RGBHV RGBS RGsB RsGsBs Standards NTSC 3 58 NTSC 4 43 PAL SECAM Input level transmitter 3 5 V to 5 5 Vp p unterminated Output level receiv...

Страница 16: ...ncondensing Cooling Convection unvented Rack mount Yes with included mounting brackets Enclosure type Metal Enclosure dimensions 1 7 H x 17 5 W x 8 5 D 1U high full rack wide 4 3 cm H x 44 4 cm W x 21...

Страница 17: ...elf adhesive 4 MBD 149 1U through desk and rack mounting kit 70 077 03 IEC power cord Tweeker small screwdriver Setup Guide Cables NOTE Enhanced Skew Free A V UTP cables are not recommended for Ethern...

Страница 18: ...82 Japan Europe and Africa Extron Europe Hanzeboulevard 10 3825 PH Amersfoort The Netherlands China Extron China 686 Ronghua Road Songjiang District Shanghai 201611 China Asia Extron Asia 135 Joo Seng...

Отзывы: