7
Extreme Networks Data Sheet:
Summit X650 Series
Power Supply Units
Summit X650 AC PSU
Dimensions and Weight
Summit X650 AC PSU
• Height: 1.57 Inches/4.0 cm
• Width: 3.2 Inches/8.1 cm
• Depth: 12.6 Inches/32.0 cm
• Weight: 3.0 lbs/1.4 kg
Power
• Voltage input range: 90 to 264 V
• Nominal input ratings: 100 to 240 V,
50/60Hz, 10 A
• Nominal input current @ full loads:
12 A @ 90 V (low-line) 5 A @ 230 V
(high-line)
• Maximum in-rush current: 100 A
• Efficiency: 80% with 60% to 100% load
• Line frequency range: 47 to 63 Hz
• Power supply input socket: IEC 320 C14
• Power cord input plug: IEC 320 C13
• Output: 12 V, 70 A max, 840 Watts, 3.3 V,
6 A max, 19.8 Watts
Summit X650 DC PSU
Dimensions and Weight
Summit X650 DC PSU
• Height: 1.57 Inches/4.0 cm
• Width: 3.2 Inches/8.1 cm
• Depth: 12.6 Inches/32.0 cm
• Weight: 3.0 lbs/1.4 kg
Power
• Voltage input range: -48 to -60 VDC
• Nominal input ratings: -39 to -72 VDC
• Nominal input current @ full loads:
26 A @ 40 V, 22 A @ 48 V, 15 A @ 72 V
• Maximum in-rush current: 18A
• Efficiency: >80% typical loads
• Minimum wire size 12 AWG (3.3 mm2)
copper stranded
• Output: 12 V, 70 A max, 840 Watts, 3.3 V,
6 A max, 19.8 Watts
All Summit X650 Series
Switches
Regulatory/Safety
North American Safety of ITE
• UL 60950-1 1st Ed., Listed Device (U.S.)
• CSA 22.2#60950-1-03 1st Ed. (Canada)
• Complies with FCC 21CFR 1040.10
(U.S. Laser Safety)
• CDRH Letter of Approval (U.S. FDA Approval)
European Safety of ITE
• EN60950-1:2006
• EN 60825-1+A2:2001 (Lasers Safety)
• TUV-R GS Mark by German Notified Body
• 2006/95/EC Low Voltage Directive
International Safety of ITE
• CB Report & Certificate per IEC 60950-
1:2006 + National Differences
• AS/NZS 60950-1 (Australia/New Zealand)
EMI/EMC Standards
North America EMC for ITE
• FCC CFR 47 part 15 Class A (U.S.A.)
• ICES-003 Class A (Canada)
European EMC Standards
• EN 55022:2006 Class A
• EN 55024:A2-2003 Class A includes
IEC 61000-4-2, 3, 4, 5, 6, 11
• EN 61000-3-2,8-2006 (Harmonics)
• EN 61000-3-3 1995+A2:2005 (Flicker)
• ETSI EN 300 386 v1.3.3, 2005-04
(EMC Telecommunications)
• 2004/108/EC EMC Directive
International EMC Certifications
• CISPR 22: 2006 Ed 5.2, Class A
(International Emissions)
• CISPR 24:A2:2003 Class A
(International Immunity)
• EC/EN 61000-4-2:2001 Electrostatic
Discharge, 8kV Contact, 15 kV Air, Criteria A
• EC/EN 61000-4-3:2006 Radiated Immunity
10V/m, Criteria A
• EC/EN 61000-4-4:2005 Transient Burst,
1 kV, Criteria A
• IEC/EN 61000-4-5:2005 Surge, 2 kV L-L,
2 kV L-G, Level 3, Criteria A
• IEC/EN 61000-4-6:2005 Conducted
Immunity, 0.15-80 MHz, 10V/m unmod.
RMS, Criteria A
• EC/EN 61000-4-11:2004 Power Dips &
Interruptions, >30%, 25 periods, Criteria C
Country Specific
• VCCI Class A (Japan Emissions)
• ACMA (C-Tick) (Australia Emissions)
• CCC Mark
• KCC Mark EMC Approval (Korea)
Telecom Standards
• EN/ETSI 300 386:2001
(EMC Telecommunications)
• EN/ETSI 300 019 (Environmental
for Telecommunications)
• MEF9 and MEF14 certified for EPL, EVPL
and ELAN
• NEBS Level 3 compliant to portions of
GR-1089 Issue 4 & GR-63 Issue 3 as defined in
SR3580 with exception to filter requirement
IEEE 802.3 Media Access
Standards
• IEEE 802.3ab 1000BASE-T
• IEEE 802.3z 1000BASE-X
• IEEE 802.3ae 10GBASE-X
• IEEE 802.3an 10GBASE-T
Environmental Standards
• EN/ETSI 300 019-2-1 v2.1.2 (2000-09) –
Class 1.2 Storage
• EN/ETSI 300 019-2-2 v2.1.2 (1999-09) –
Class 2.3 Transportation
• EN/ETSI 300 019-2-3 v2.1.2 (2003-04) –
Class 3.1e Operational
• EN/ETSI 300 753 (1997-10) – Acoustic Noise
• ASTM D3580 Random Vibration
Unpackaged 1.5G
Security
• Common Criteria EAL3+
Warranty
• Ltd. 1-year on Hardware
• 90-days on Software
• For warranty details, visit
www.extremenetworks.com/go/warranty