background image

2

Extreme Networks Data Sheet: 

Summit X250e Series

Technical Specifications

Voice-Class Availability  

Modular Operating System for High Availability 

Operation

Preemptive Multitasking and Protected Memory

Summit X250e switches allow each of many applications—such as Open 
Shortest Path First (OSPF) and Spanning Tree Protocol (STP)—to run as 
separate Operating System (OS) processes that are protected from each 
other. This drives increased system integrity and helps protect against 
Denial of Service (DoS) attacks.   

Process Monitoring and Restart

ExtremeXOS improves network availability using process monitoring and 
restart. Each independent OS process is monitored in real time. If a process 
becomes unresponsive or stops running, it can be automatically restarted. 

Loadable Software Modules

The modular design of the ExtremeXOS OS allows the upgrading of 
individual software modules, should this be necessary, leading to higher 
availability in the network (see Figure 1). 

High Availability Network Protocols 

Ethernet Automatic Protection Switching (EAPS)

EAPS allows the IP network to provide the level of resiliency and uptime 
that users expect from their traditional voice network. EAPS differs from 
Spanning Tree or Rapid Spanning Tree protocols and offers sub-second 
(less than 50 milliseconds) recovery that helps deliver consistent failover 
regardless of the number of VLANs, network nodes or network topology. 
Since EAPS allows the network to recover almost transparently, VoIP calls will 
not drop and digital video feeds will not freeze or pixelize in most situations. 

Spanning Tree/Rapid Spanning Tree Protocols

Summit X250e switches support Spanning Tree (802.1D), Per VLAN 
Spanning Tree (PVST+), Rapid Spanning Tree (802.1w) and Multiple 
Instances of Spanning Tree (802.1s) protocols for Layer 2 resiliency.  

Software-Enhanced Availability

Software-enhanced availability allows users to remain connected to the 
network even if part of the network infrastructure is down. Summit X250e 
switches continuously check for problems in the uplink connections using 
advanced Layer 3 protocols such as OSPF, VRRP and Extreme Standby 
Router Protocol™ (ESRP, supported in Layer 2 or Layer 3), and dynamically 
route traffic around the problem.  

Equal Cost Multipath Routing

Equal Cost Multipath (ECMP) routing allows uplinks to be load balanced for 
performance and cost savings while also supporting redundant failover. If 
an uplink fails, traffic is automatically routed to the remaining uplinks and 
connectivity is maintained.    

Link Aggregation (802.3ad)

Link aggregation allows trunking of up to eight links on a single logical 
connection, for up to 2 Gigabits per Second (Gbps) of redundant 
bandwidth per logical connection.      

Multi-Switch LAG (M-LAG)

M-LAG can address bandwidth limitations and improve network resiliency, 
in part by routing network traffic around bottlenecks, reducing the risks of 
a single point of failure, and allowing load balancing across multiple switches.

Voice-Grade Stacking with SummitStack

Summit X250e offers dual stacking interfaces to provide high-speed 40 
Gbps stacking bandwidth. SummitStack architecture is designed to support 
converged services by its highly available, rapid failover capability with n-1 
master redundancy, distributed Layer 2 and Layer 3 switching, link 
aggregation across the stack and distributed uplinks. SummitStack 
supports up to eight units in a stack (the mixture of the units can be 
Summit X250e, X450e, X450a, X460, X480 and X650 series switches 
running the same version of ExtremeXOS) and provides sub-second 
failover for path failure and hitless master/backup failover along with hitless 
protocol support such as OSPF graceful restart, PoE configuration and 
Network Login user authentication. 

Summit X250e provides chassis-like management and availability with its 
SummitStack stacking technology (see Figure 2).

5027-06

• Processes are monitored and can be restarted 

   or other action taken if necessary
• Hitless failover infrastructure for dual management 

   systems and stacking

Memory protected 

processes under 

real-time 

scheduling that 

cannot impact 

each other nor 

kernel

1

Designed to allow 

application 

modules to be 

upgraded during 

runtime

3

Application 

modules can be 

added during 

runtime

2

SSH-2 

V1.3.2

BGP

OSPF

Third

Party

Application

SSH-2 

V1.3.1

ExtremeXOS®

Kernel

Kernel Loadable

Module

Figure 1: ExtremeXOS Modular Design

5251-03

• Single management point for up to eight units
• High-speed 40 Gbps stacking
• Rapid Failover for converged applications
• Can mix Summit

®

 X250e, Summit X450a/e series, 

   Summit X460, Summit X480 and Summit X650 series switches

   for SummitStack™ 40 Gbps stacking

Figure 2: SummitStack Stacking Architecture

Содержание Summit X250e Series

Страница 1: ...rtification Highlights Summit X250e series switches are based on Extreme Networks revolutionary ExtremeXOS core class operating system ExtremeXOS is a highly resilient modular operating system that helps provide continuous uptime manageability and operational efficiency at an affordable price Summit X250e provides high availability and performance with its advanced traffic management capabilities ...

Страница 2: ...t Multipath Routing Equal Cost Multipath ECMP routing allows uplinks to be load balanced for performance and cost savings while also supporting redundant failover If an uplink fails traffic is automatically routed to the remaining uplinks and connectivity is maintained Link Aggregation 802 3ad Link aggregation allows trunking of up to eight links on a single logical connection for up to 2 Gigabits...

Страница 3: ...s Granular QoS low latency and low jitter enable voice quality connections Summit X250e supports a range of QoS technologies that can prioritize and predictably handle high priority traffic policing or rate limiting on ingress 802 1Q tagging and Diffserv marking and shaping on egress with eight queues per port The Extreme Networks tradition of building products with low latency and jitter continue...

Страница 4: ...files based on organizational structure or other logical groupings and apply them across multiple users to allow appropriate access to network resources In addition support for Wide Key ACLs further improves security by going beyond the typical source destination and MAC address as identification criteria access mechanism to provide filtering capabilities Host Integrity Checking Host integrity che...

Страница 5: ...rity scalability availability mobility or management Edge Connectivity for Advanced Carrier Ethernet Applications Carrier Ethernet edge switching with 100BASE X provides advanced fiber connectivity to the customer Summit X250e is deployed as an intelligent Fast Ethernet edge switch extending the benefits of the ExtremeXOS operating system to the network edge in the Carrier Ethernet network This un...

Страница 6: ...50DC and EPS T2 EPS 150DC is the redundant DC Power Supply for DC PSU based Summit switches The EPS T2 power tray is required to rack mount this external power supply EPS T2 power tray can take up to two EPS 150DC power modules and each EPS 150DC works individually EPS 150DC comes with a DC output cable to connect between the Summit switch and EPS 150DC Front View Front View Front View Front View ...

Страница 7: ...with 60 100 load Line Frequency Range 47 63 Hz Power Supply Input Socket IEC 320 C14 Summit X250e 48t General Specifications Performance 97 6 Gbps switch fabric bandwidth 39 9 Mpps frame forwarding rate 9 216 Byte maximum packet size Jumbo Frame 128 load sharing trunks up to 8 members per trunk 8 QoS queues port 4 094 VLANs Port Protocol IEEE 802 1Q 1 024 centralized ACL rules per 24 port Forwardi...

Страница 8: ...67 2 BTU h Power Consumption 49W 167 2 BTU h Acoustic Noise Low FAN Speed 37 dBA per ISO 7779 Acoustic Noise High FAN Speed 45 dBA per ISO 7779 Indicators Per port status LED System Status LEDs management fan and power Ports 24 ports 10 100BASE T PoE with auto speed and auto polarity 2 ports Gigabit Ethernet 100 1000BASE X SFP shared PHY with 2 10 100 1000BASE T ports 2 SummitStack stacking interf...

Страница 9: ...following capability depending upon the number of EPS 600LS installed One EPS 600LS Redundant up to 370W PoE power Two EPS 600LS Redundant up to 370W PoE power Non Redundant up to 740W PoE power Three EPS 600LS Redundant up to 740W PoE power Physical Specifications Dimensions and Weight Height 1 73 Inches 4 4 Cm Width 17 35 Inches 44 1 Cm Depth 15 28 Inches 38 8 Cm Weight 12 06 lbs 5 48 Kg Operati...

Страница 10: ...on 31W 105 8 BTU h Acoustic Noise Low FAN Speed 37 dBA per ISO 7779 Acoustic Noise High FAN Speed 45 dBA per ISO 7779 Summit X250e 24tDC General Specifications Performance 97 6 Gbps switch fabric bandwidth 39 9 Mpps frame forwarding rate 9 216 Byte maximum packet size Jumbo Frame 128 load sharing trunks up to 8 members per trunk 8 QoS queues port 4 094 VLANs Port Protocol IEEE 802 1Q 1 024 central...

Страница 11: ...rds North American Safety of ITE UL 60950 1 1st Ed Listed Device U S CSA 22 2 60950 1 03 1st Ed Canada Complies with FCC 21CFR 1040 10 U S Laser Safety CDRH Letter of Approval U S FDA Approval European Safety of ITE EN60950 1 2001 A11 EN 60825 1 A2 2001 Lasers Safety TUV R GS Mark by German Notified Body 2006 95 EC Low Voltage Directive International Safety of ITE CB Report Certificate per IEC 609...

Страница 12: ...erational Shock Half Sine 30 m s2 3g 11ms 60 Shocks Operational Random Vibration 5 500 Hz 1 5g rms Storage Transportation Conditions Packaged Transportation Temperature 40 C to 70 C 40 F to 158 F Storage and Transportation Humidity 10 to 95 RH non condensing Packaged Shock Half Sine 180 m s2 18g 6ms 600 shocks Packaged Sine Vibration 5 62 Hz Velocity 5mm s 62 500 Hz 0 2 G Packaged Random Vibration...

Страница 13: ... 320 C13 Heat Dissipation 158W 539 1 BTU h Power Consumption 659W 2448 6 BTU h Dimensions and Weight EPS C Height 1 73 Inches 4 4 Cm Width 17 32 Inches 44 0 Cm Depth 11 81 Inches 30 0 Cm Weight 7 17 Lbs 3 16 Kg EPS 600LS Height 1 69 Inches 4 3 Cm Width 4 61 Inches 11 7 Cm Depth 11 81 Inches 30 9 Cm Weight 3 74 Lbs 1 70 Kg Power EPS 600LS Voltage Input Range 90 264 V Nominal Input Voltage Hz 115V 6...

Страница 14: ...dundant power system chassis requires EPS 600LS 15107T Summit X250e 48p TAA U S Federal TAA 48 10 100BASE TX with PoE 2 gigabit combo ports 2 unpopulated gigabit SFP and 10 100 1000BASE T 2 SummitStack stacking ports ExtremeXOS Edge license 1 AC PSU connector for EPS C external redundant power system chassis requires EPS 600LS 15109 Summit X250e 24x 24 100BASE X SFP 2 gigabit combo ports 2 unpopul...

Страница 15: ...EPS 150DC power modules Add one EPS 150DC for each redundantly powered system 10051 SX SFP 1000BASE S SFP 1000BASE SX LC Connector 10052 LX SFP External Power System 500 Watts Power cord ordered separately 10053 ZX SFP 1000BASE ZX SFP Extra Long Distance SMF 70 km 21 dB Budget LC Connector 10064 LX100 SFP 1000BASE LX100 SFP Extra Long Distance SMF 100 km 30 dB Budget LC Connector 10056 1000BX SFP ...

Отзывы: