Selecting Power Supply Cords

 

BlackDiamond 12800 Series Switches Hardware Installation Guide

137

Black Diamond SSI DC PSU, Model 60021:

Wire: three conductor, 8 AWG, jacketed, and marked 90C min 

NOTE

Tray Cable is a UL US-only requirement. Outside United States standard 8 AWG (8.35mm

2

), 90C wire is 

acceptable.

Wall plug: N/A, 3-conductor wires have been stripped and are ready for connection to DC power 
source mains

Device connector: Molex Shell Connector PN 42816-0312; Molex Pin Connectors PN 42815-0032 

Assembly rating: 75VDC, 30A, (Do not disconnect under load)

Black Diamond 325 W AC PSU Model 65021:

Wire: 18 AWG (0.82mm2) minimum, 3-conductor flexible cable, Type SVT, SJT, HAR or equivalent, 
no longer then 10ft

Wall plug: Suitable for use in country of installation & approved by local regulatory authority

Device connector: IEC320-C13, 90 degree angle, rated at 15 A, 250 VAC

Power cord assembly: Must be rated at 10A by in-country regulatory authority

Black Diamond 325 W DC PSU, Model 60021:

Wire: UL LISTED, three conductor, 14 AWG, jacketed, and marked (UL) FT2, 90C min 

NOTE

Tray Cable is a UL US-only requirement. Outside United States standard 8 AWG (8.35mm

2

), 90C wire is 

acceptable.

Wall plug: N/A, 3-conductor wires have been stripped and are ready for connection to DC power 
source mains

Device connector: Molex Shell Connector PN 42816-0312; Molex Pin Connectors PN 42815-0032 

Assembly rating: 75VDC, 30A, (Do not disconnect under load)

WARNING!

When using multiple power supplies, make sure that each power supply is attached to independent circuits breakers. 
See PS installation instructions of PS for proper sizing of circuit breaker.

Make sure that the source outlet is properly grounded according to the country’s local electrical requirements before 
plugging the AC supply power cord into a PSU.

For specific product input power requirements refer to the data sheet of the product or modular PSU at http://
www.extremenetworks.com or to Appendix B of this guide.

The following countries have specific safety instructions concerning power connectors:

Argentina: The supply plug must comply with Argentinean standards.

Australia: Use AS 3112 for 110/220 VAC power supplies.

Denmark: The supply plug must comply with section 107-2-D1, standard DK2-1a or DK2-5a.

International: Use CEE 7/7 for 110/220 VAC power supplies.

Japan:

Содержание BlackDiamond 12800 Series

Страница 1: ...Clara California 95051 888 257 3000 408 579 2800 http www extremenetworks com BlackDiamond 12800 Series Switches Hardware Installation Guide BlackDiamond 12802 Switch BlackDiamond 12804 Switch Publis...

Страница 2: ...marks or registered trademarks of Extreme Networks Inc or its subsidiaries in the United States and or other countries Adobe Flash and Macromedia are registered trademarks of Adobe Systems Incorporate...

Страница 3: ...es 19 BlackDiamond 12800 Series MSMs 20 Software Requirements 20 Redundant MSM Activity BlackDiamond 12804 Switch 21 MSM LEDs 21 Features of the BlackDiamond 12800 MSMs 22 BlackDiamond 12800 Series I...

Страница 4: ...cifications and Recommendations 46 Mechanical Recommendations for the Rack 46 Protective Grounding for the Rack 46 Space Requirements for the Rack 47 Securing the Rack 47 Evaluating and Meeting Cable...

Страница 5: ...0 W DC PSU 76 Removing an Extreme Networks 1200 W DC PSU 79 Front Panel LEDs 80 Extreme Networks 700 1200 W AC PSU 81 Pre Installation Requirements 81 Installing an Extreme Networks 700 1200 W AC PSU...

Страница 6: ...roller 115 Pre Installation Requirements 115 Removing a BlackDiamond 12804 PSU Fan Controller 116 Installing a Replacement BlackDiamond 12804 PSU Fan Controller 117 Replacing a BlackDiamond 12802 PSU...

Страница 7: ...r Supply Cords 136 Battery Replacement and Disposal 138 Fiber Optic Ports Optical Safety 138 GBIC SFP Mini GBIC XENPAK and XFP Regulatory Compliance 139 Appendix B Technical Specifications 147 BlackDi...

Страница 8: ...Table of Contents BlackDiamond 12800 Series Switches Hardware Installation Guide 8...

Страница 9: ...s BlackDiamond 12800 series switches This guide also contains information about site preparation switch functionality and switch operation This guide is intended for use by network administrators resp...

Страница 10: ...to Note Important features or instructions Caution Risk of personal injury system damage or loss of data Warning Risk of severe personal injury Table 2 Text conventions Convention Description Screen d...

Страница 11: ...documentation from the Documentation Overview page Software User Guides Hardware User Guides You can find archived user guides for software at http www extremenetworks com services documentation swus...

Страница 12: ...Preface BlackDiamond 12800 Series Switches Hardware Installation Guide 12...

Страница 13: ...1 BlackDiamond 12800 Series Switches...

Страница 14: ......

Страница 15: ...of these switches include I O modules that are hot swappable and include Gigabit Ethernet copper ports 10 100 1000 and Gigabit Ethernet fiber ports SFP or 10 Gigabit Ethernet ports Management Switch...

Страница 16: ...emeXOS and for other functions including capturing debug information and core dump files See the ExtremeXOS 12 0 Concepts Guide for more information regarding the use of the external compact flash mem...

Страница 17: ...he BlackDiamond 12804 Chassis The rear panel of the BlackDiamond 12804 chassis provides Chassis serial number Ethernet MAC address of the switch Symbols of safety certification Access to the PSU fan c...

Страница 18: ...fan tray Figure 3 shows a BlackDiamond 12802 chassis equipped with one MSM and two I O modules Figure 3 Front of the BlackDiamond 12802 Chassis Figure 4 shows the rear panel of the BlackDiamond 12802...

Страница 19: ...the advanced QoS features and scale The R series modules support rate limiting which is the ability to control bandwidth throughout the network For complete details about rate limiting refer to the Ex...

Страница 20: ...from the two different series The ExtremeXOS software recognizes the MSM type installed in your BlackDiamond 12800 series switch and only allows use of a second MSM of the same type and compatible I O...

Страница 21: ...MSMs can be inserted and removed without disrupting network services If you remove the primary MSM while the switch is operating the secondary MSM performs a soft reset and then becomes the primary MS...

Страница 22: ...injector levers and captive retaining screws at each end of the module front panel The MSMs have the following features on the front panel Console port The DB 9 serial console port is used to connect...

Страница 23: ...module provides the same functionality as the MSM 5R module with higher performance for CPU based activities such as BGP OSPF and MPLS BlackDiamond 12800 Series I O Modules No configuration informati...

Страница 24: ...agnostic failure or other severe module error Off No power DIAG Off Normal operation Amber blinking Diagnostics in progress Amber Diagnostic failure Table 7 Port LEDs for the BlackDiamond GM 20XT GM 2...

Страница 25: ...llows All ports Are added to the default VLAN as untagged Inherit the properties of the default VLAN for example protocol type and VLANid Operate in autonegotiation mode GM 20T LEDs The GM 20T I O mod...

Страница 26: ...er port can be active but not both You can set up a redundant link by connecting both the copper and fiber ports in the pair The port that is connected first becomes the active port If that port fails...

Страница 27: ...use rate limiting you must install the MSM 5R plus the GM 20XTR I O module and or the XM 2XR I O module The XM 2X module and XM 2XR module have two unpopulated XENPAK based 10 Gigabit Ethernet ports...

Страница 28: ...e unpopulated XENPAK based 10 Gigabit Ethernet port The default configuration of the XM 2HR I O module is as follows All ports Are added to the default VLAN as untagged Inherit the properties of the d...

Страница 29: ...n the PSU does not contain user serviceable parts In the event of failure return the defective PSU to Extreme Networks for repair or replacement Overview of BlackDiamond 12800 Series Power Supplies Th...

Страница 30: ...pplies can provide A B feed redundancy for the system The input DC cable has an input connector on one end and precut wire on the other end that goes to the DC power source see Figure 15 The connector...

Страница 31: ...t to open the 1200 W DC PSU enclosure for any reason the PSU does not contain user serviceable parts In the event of failure return the defective 1200 W DC PSU to Extreme Networks for repair or replac...

Страница 32: ...700 1200 W AC PSU enclosure for any reason the PSU does not contain user serviceable parts In the event of failure return the defective 700 1200 W AC PSU to Extreme Networks for repair or replacement...

Страница 33: ...allation Power supply cords must be less than 5 m long Wire size must be a minimum of 16 AWG 1 0 mm2 copper stranded WARNING Always be sure that the source outlet is properly grounded before plugging...

Страница 34: ...to the 700 1200 W AC PSU Make sure that this connection is easily accessible Make sure that the 700 1200 W AC PSU circuit is not overloaded Use proper over current protection such as a circuit breaker...

Страница 35: ...ated power source that delivers 40 to 72 VDC constant power to each 325 W DC PSU Power distribution to the 325 W DC PSU shall be provided using the Model 65025 48 V DC cable Power to the 325 W DC PSU...

Страница 36: ...Specifications The 325 W DC PSU functions from 40 V to 72 V DC input The software determines the maximum available power required for the switch and enables the modules accordingly CAUTION The 325 W...

Страница 37: ...Extreme Networks are designed for use in the United States and Canada only Power supply cords for use outside of North America are typically provided by a third party distribution center and must meet...

Страница 38: ...fused This is not a field operator replaceable fuse In the event of failure immediately return the Extreme Networks 325 W AC PSU for a complete replacement WARNING Field operators must not attempt to...

Страница 39: ...2 Installing BlackDiamond Switches and Modules...

Страница 40: ......

Страница 41: ...e personnel only Qualified service personnel have had appropriate technical training and experience that is necessary to be aware of the hazards to which they are exposed when performing a task and of...

Страница 42: ...e following websites International Code Council ICC 5203 Leesburg Pike Falls Church Virginia 22041 USA http www iccsafe org http www sbcci org Five authorities on electrical codes are National Electri...

Страница 43: ...that only qualified service personnel have access to the equipment Provide adequate overhead lighting for easy maintenance Be sure that each wiring closet has a suitable ground All equipment racks and...

Страница 44: ...n two sets of three adjacent BlackDiamond switches or Place patch panels between two sets of three adjacent BlackDiamond switches A patch panel does not require any power and does not generate any hea...

Страница 45: ...ration such as synthetic resins from the wiring closet Check the appropriateness of floor mats and flooring Connect metal chassis conduit and other metals to ground using dedicated grounding lines Use...

Страница 46: ...ried back to earth or to another suitable building ground BlackDiamond 12800 series switches are designed with mounting ears that provide metal to metal contact for grounding Extreme Networks switches...

Страница 47: ...space behind the mounted equipment Extra room on each side is optional WARNING A BlackDiamond chassis does not have a switch for turning power to the unit on and off For systems using an AC power sup...

Страница 48: ...n planning and installing a network Maintaining accurate records helps you to Relocate devices easily Make changes quickly Isolate faults in the distribution system Locate the opposite end of any cabl...

Страница 49: ...t on the switch When required for safety and fire rating requirements use plenum rated cable See your local building codes for determining when it is appropriate to use plenum rated cable or refer to...

Страница 50: ...cable has a minimum bend radius for example and fibers will be damaged if the cables are bent too sharply It is also important not to stretch the cable during installation We recommend that the bend...

Страница 51: ...orks Connections between two Extreme Networks 1000BASE LX interfaces that use 10 125 m single mode fiber can use a maximum distance of 10 000 meters Table 14 Media Types and Maximum Distances Standard...

Страница 52: ...ature Using cable with jackets that are wider than the connectors can cause Connectors that are not properly aligned with the port Crowded cable installation which can cause connectors to pop out of t...

Страница 53: ...e fiber optic cabling or shielded twisted pair cabling STP Meeting Power Requirements This section describes power requirements including Power Supply Requirements AC Power Cable Requirements Uninterr...

Страница 54: ...uirements An uninterruptible power supply UPS is a device that sits between a power supply such as a wall outlet and a device such as a switch to prevent outages sags surges and bad harmonics from adv...

Страница 55: ...e protection Calculating Volt Amperage Requirements To determine the minimum volt amperage requirements for your UPS 1 Locate the voltage and amperage requirements for each piece of equipment These nu...

Страница 56: ...EIA standards ANSI TIA EIA 568 A discusses the six subsystems of a structured cabling system ANSI TIA EIA 569 A discusses design considerations ANSI TIA EIA 606 discusses cabling system administration...

Страница 57: ...install the following BlackDiamond chassis models BlackDiamond 12804 chassis BlackDiamond 12802 chassis The BlackDiamond 12800 series chassis fits into a standard 19 inch 48 26 cm rack You can install...

Страница 58: ...ation pack from the shipping carton see Figure 26 Lift out the packing foam Figure 26 Removing Accessories from the BlackDiamond 12804 Chassis Shipping Carton 3 Release the clip locks see Figure 27 a...

Страница 59: ...he BlackDiamond 12804 Chassis Shipping Carton 4 Slide the shipping carton up over the BlackDiamond 12804 chassis see Figure 28 Figure 28 Removing the Carton from the BlackDiamond 12804 Chassis 5 Unwra...

Страница 60: ...t of the chassis Verify that the following items are included in the crate BlackDiamond 12804 chassis with four installed blank front panels Power cord retaining bracket 19 inch helper bracket install...

Страница 61: ...e for the rack mounting screws you will use The screwdriver size will vary based on the requirements of your organization s rack system Surface cleaner Antioxidant treatment Attaching the BlackDiamond...

Страница 62: ...unt the BlackDiamond 12804 chassis in a rack 1 Locate the 19 inch helper bracket that is shipped with the BlackDiamond 12804 chassis 2 Identify the rack location where the chassis will be installed 3...

Страница 63: ...804 chassis onto the helper bracket 6 Slowly guide the chassis into the system rack until the mounting brackets are flush against the rack uprights 7 Attach the chassis to the system rack using eight...

Страница 64: ...sis from the rack Unpacking the BlackDiamond 12802 Chassis CAUTION Proper lifting of the BlackDiamond 12802 chassis requires two people To unpack the BlackDiamond 12802 chassis 1 Break the inspection...

Страница 65: ...ION Do not lift the chassis using the top of the front opening The weight of the chassis may cause the enclosure to deform Set the chassis on a secure flat work surface 6 Break the inspection seal on...

Страница 66: ...u need the following tools and equipment to install the chassis in a rack 8 rack mounting screws The screw size will vary based on your organization s rack system screws are not provided Screwdriver a...

Страница 67: ...k using eight rack mounting screws Refer to Figure 35 for the screw locations Figure 35 Securing the BlackDiamond 12802 Chassis to the Rack Front mount Position Mid Mounting a BlackDiamond 12802 Chass...

Страница 68: ...is recommended A grounding point with integrated pem nuts is provided on the back of the chassis You need the following materials to ground the chassis Two 10 24 screws 1 inch or shorter One copper s...

Страница 69: ...from the stranded copper wire cable 3 Insert the stripped wire into the cable lug CAUTION Be sure that no copper is visible between the lug and the cable insulation 4 Crimp the lug onto the cable acco...

Страница 70: ...works switch must be configured with these settings This procedure is described in the documentation supplied with the terminal Appropriate shielded serial cables are available from your local supplie...

Страница 71: ...de 5 At the password prompt press Return The default user name admin has no password assigned to it When you have successfully logged on to the system the command line prompt displays the system name...

Страница 72: ...Installing the BlackDiamond 12800 Series Chassis BlackDiamond 12800 Series Switches Hardware Installation Guide 72...

Страница 73: ...r network Read the latest installation and safety information provided in this chapter and in Appendix A Safety Information See Appendix A Safety Information for additional information regarding regul...

Страница 74: ...ons the 1200 W DC PSU is intended to be installed only in a restricted access location such as a dedicated equipment room equipment closet or central office in accordance with Articles 110 16 110 17 a...

Страница 75: ...source should be a Common Bond Network CBN according to GR 1089 Power distribution to the 1200 W DC PSU shall be provided using the 48 VDC harness provided Power to the 1200 W DC PSU can be from eithe...

Страница 76: ...ont panel CAUTION Be sure that the grounding point on the back of the switch is securely connected to earth ground For information about grounding the switch see Grounding the BlackDiamond 12800 Serie...

Страница 77: ...DC PSU into the system switch backplane Figure 42 Inserting the 1200 W DC PSU into the Power Supply Bay 4 Connect the input DC cable to the front of the 1200 W DC PSU as shown in Figure 43 NOTE An AC...

Страница 78: ...xit out the right side of the grate The right most cable harness should be routed across the switch and exit out the left side of the grate It is important to route each of the outer most cables out t...

Страница 79: ...the cable from the front of the DC PSU by pressing down the catch see Figure 44 and pulling out the cable Figure 44 Disconnecting the Cable from the DC PSU WARNING Always be sure that the 1200 W DC P...

Страница 80: ...ED behavior Table 17 Extreme Networks 1200 W DC PSU LEDs PSU Condition Power Green Predictive Fail Amber Fail Amber Power supply DC outputs working normally On Off Off DC input power present standby o...

Страница 81: ...e power to an Extreme Networks 700 1200 W AC PSU Make sure that this connection is always easily accessible Do not plug the power supply into an electrical outlet outside of the chassis doing so would...

Страница 82: ...treme Networks 700 1200 W AC PSU into the system switch backplane Use the locking handle to secure the Extreme Networks 700 1200 W AC PSU into the system switch Figure 46 Inserting the 700 1200 W AC P...

Страница 83: ...hrough 5 Removing an Extreme Networks 700 1200 W AC PSU CAUTION The AC PSU may be hot to the touch use thermal protective gloves when handling the 700 1200 W AC PSU during removal To remove an Extreme...

Страница 84: ...rd party distribution center and must meet the following requirements Power supply cords must be agency certified for country of use Power supply cords must contain an IEC 320 C13 connector on the end...

Страница 85: ...ircuit breaker to prevent over current conditions Using the BlackDiamond12804 AC Power Cord Retainer Channel The AC power cord retaining channel for the BlackDiamond 12804 switch holds the power conne...

Страница 86: ...AC power cord retainer channel in the position shown in Figure 48 Figure 48 BlackDiamond 12804 AC Power Cord Retainer 4 Place the retainer channel against the switch as shown in Figure 49 Tighten the...

Страница 87: ...o power cords on top of the bottom four cords see Figure 50 Figure 50 Routing the Power Cords in the Channel NOTE Leave the ESD preventive wrist strap permanently connected to the switch so that the s...

Страница 88: ...nts Extreme Networks 325 W DC Power Supply This section describes how to install the Extreme Networks 325 W DC UL listed accessory power supply unit PSU Model 65022 in a BlackDiamond 12802 switch NOTE...

Страница 89: ...65052 shipped separately from the PSU Thermal protective gloves required for removal Installing the DC Wiring NOTE All wiring methods involving the DC input cable assembly must be performed according...

Страница 90: ...o the 325 W DC PSU or disconnect the DC power cord from the 325 W DC PSU WARNING Wiring the 325 W DC PSU DC power cord to your facility DC source voltage must be performed by a qualified licensed elec...

Страница 91: ...er to Table 19 for the recommended installation sequence NOTE A minimum of two Extreme Networks 325 W DC PSUs are required to run a BlackDiamond 12802 switch WARNING Do not put your hand into an open...

Страница 92: ...Securing the Extreme Networks 325 W DC PSU 5 Verify that the DC input cord was connected to a permanent DC voltage source by a qualified licensed electrician 6 Verify that the DC power is turned off a...

Страница 93: ...disconnect ALL power supply units Disconnect the power cord before you remove the PSU from the chassis To remove an Extreme Networks 325 W DC PSU 1 Turn off the DC power at the source 2 Attach an ESD...

Страница 94: ...er supply unit Model 65021 in the BlackDiamond 12802 switch NOTE The Extreme Networks 325 W AC PSU cannot be used in combination with any other Extreme Networks PSU Pre Installation Requirements WARNI...

Страница 95: ...5 W AC PSU CAUTION Make sure that the Extreme Networks 325 W AC PSU circuit is not overloaded Use proper over current protection such as a circuit breaker to prevent over current conditions To install...

Страница 96: ...To prevent an electrical hazard make sure before you install the PSU in the power supply bay that the AC power cord is not connected to the PSU Figure 57 Installing a 325 W AC PSU 4 To secure the 325...

Страница 97: ...bration or other disturbances Install the power cord retaining brackets before you connect the power cords To install the brackets and connect power to the switch 1 Attach a power cord retaining brack...

Страница 98: ...ws a Connect the AC power cord to the AC input on the front of the PSU see Figure 61 If needed loosen the middle screw of the power cord bracket to allow installation of the power cord b After the pow...

Страница 99: ...on the power cord bracket to allow removal of the power cord After the screws are loosened disconnect the AC power cord from the AC input on the front of the PSU 4 Loosen the two captive screws that s...

Страница 100: ...C14 receptacle on the PSU Power supply cords must contain an appropriately rated and approved wall plug applicable to the country of installation Power supply cords must be less than 5 m long Wire si...

Страница 101: ...8 NOTE Read the information in this chapter thoroughly before you attempt to install or remove BlackDiamond 12800 series MSM or I O module CAUTION Do not attempt to mix modules across Extreme Networks...

Страница 102: ...ckDiamond 12800 series MSM or I O module ESD preventive wrist strap 2 Phillips screwdriver Appropriate type of cable for the module if you are installing an I O module CAUTION The module series number...

Страница 103: ...and firmly grasp the rail of the module d Pull the antistatic bag off while holding the rail of the module CAUTION To prevent ESD damage hold the module by the metal rail and front panel only Never to...

Страница 104: ...or ejector handle clockwise and completely down When the screw is completely tightened the yellow band around the captive screw is completely hidden CAUTION Be careful to avoid over torquing and strip...

Страница 105: ...3 If you are using optical fiber cable align the transmit Tx and receive Rx connectors with the correct corresponding connectors on the switch or the I O module 4 Press the cable connectors into their...

Страница 106: ...as no problems the command show slot slot where slot is the number of the slot where you installed the module displays information about the module including general information about the module name...

Страница 107: ...ght corner 2 Unlock the module in one of the following ways On a module without red lines on the screwheads turn each captive screw counter clockwise Figure 67 Verify that the yellow band around the c...

Страница 108: ...d switches are shipped with blank front panels installed over one or more chassis slots You can remove or install a blank front panel at any time without disrupting network services Complete the actio...

Страница 109: ...t secured NOTE Leave the ESD preventive wrist strap permanently connected to the chassis so that it is always available when you need to touch ESD sensitive components Removing a Blank Front Panel To...

Страница 110: ...ond switch see Figure 71 Figure 71 Removing a Blank Front Panel from a BlackDiamond 12800 Series Switch 4 Install an I O module or MSM in the open slot as described in Installing a BlackDiamond 12800...

Страница 111: ...5 Carefully push the card until it is seated into the slot The card should be fully inserted or seated inside the slot 6 To verify that the card is fully seated use the show memorycard command To rem...

Страница 112: ...Installing Modules and Connecting Cables BlackDiamond 12800 Series Switches Hardware Installation Guide 112...

Страница 113: ...3 BlackDiamond Maintenance Procedures...

Страница 114: ......

Страница 115: ...kDiamond equipment should be performed by trained service personnel only Read all important safety information before installation or removal See Appendix A for additional information regarding regula...

Страница 116: ...nd connect the metal end to the ground receptacle on the front top left corner of the switch 2 Locate the eight captive screws on the PSU fan controller access cover at the back of the BlackDiamond 12...

Страница 117: ...Attach the ESD preventive wrist strap to your wrist and connect the metal end to the ground receptacle on the front top left corner of the switch 2 Align the guide pins in the empty controller recess...

Страница 118: ...eplace the PSU fan controller To replace a BlackDiamond PSU fan controller you need the following tools and equipment ESD preventive wrist strap 2 Phillips screwdriver Replacement BlackDiamond 12802 P...

Страница 119: ...switch so that it will always be available when you need to handle ESD sensitive components Replacing a BlackDiamond 12804 Fan Tray The BlackDiamond 12804 switch has one fan tray that is accessible fr...

Страница 120: ...Switch 4 Use the fan tray handle to pull the fan tray half way out from the fan tray slot This action disconnects the fan tray from the switch power Wait for the fan blades to stop turning before con...

Страница 121: ...Be sure that both hands are used to support the weight of the fan tray during installation Figure 78 Installing the Fan Tray in the BlackDiamond 12804 Switch 3 Use a 2 Phillips screwdriver to tighten...

Страница 122: ...rner of the switch 2 Locate the captive screws at the top and bottom of the fan tray Figure 79 3 Using a 2 Phillips screwdriver loosen the screws until they are free of the switch back panel see Figur...

Страница 123: ...gn the fan tray with the fan tray slot on the switch and then slide the fan tray into place in the switch see Figure 80 CAUTION Use both hands to support the weight of the fan tray during installation...

Страница 124: ...Replacing BlackDiamond 12800 Series Chassis Components BlackDiamond 12800 Series Switches Hardware Installation Guide 124...

Страница 125: ...formation CAUTION Correct lifting procedures for a BlackDiamond chassis require two or more people Only trained service personnel should perform service to Extreme Networks switches and their componen...

Страница 126: ...t rack mounting screws that secure the chassis to the system rack 4 On each side of the chassis place one hand in the empty power supply bay and the other hand in the rear slot on the back panel of th...

Страница 127: ...prongs b Squeeze the prongs inward applying equal pressure on each side c Push the prongs inward until the clip lock is secured onto the carton Repeat steps 8a through 8c to insert each of the remain...

Страница 128: ...cking tape 11 Secure the shipping carton with nylon straps see Figure 85 NOTE Nylon straps are optional but are recommended by Extreme Networks for extra security during shipment The installation of n...

Страница 129: ...for removing components from the BlackDiamond chassis 3 Remove the chassis from the equipment rack as follows a Loosen and remove the eight mounting screws holding the chassis to the rack b Guide the...

Страница 130: ...Repacking a BlackDiamond Chassis BlackDiamond 12800 Series Switches Hardware Installation Guide 130...

Страница 131: ...4 Appendixes...

Страница 132: ......

Страница 133: ...rk telecommunications facility Choose an indoor area that has the following characteristics Temperature and humidity controlled such that the maximum ambient room temperature shall not exceed 40 C 104...

Страница 134: ...ot swappable power supply into the bay do not use excessive force If multiple power supplies are used in a switch connect each power supply to a different independent power source If a single power so...

Страница 135: ...maintenance procedure Disconnect all power cords before working near power supplies unless otherwise instructed by a maintenance procedure When handling modules optic devices power supplies or other m...

Страница 136: ...o errors or damage PoE Devices When connecting power over Ethernet PoE devices to a PoE switch all connections between the PoE device and the switch must remain inside the same building and use a low...

Страница 137: ...in NOTE Tray Cable is a UL US only requirement Outside United States standard 8 AWG 8 35mm2 90C wire is acceptable Wall plug N A 3 conductor wires have been stripped and are ready for connection to DC...

Страница 138: ...an electrical contractor to ensure proper equipment grounding and power distribution for your specific installation country Battery Replacement and Disposal Batteries included with Extreme products a...

Страница 139: ...meet the following regulatory requirements Class 1 Laser Product EN60825 1 A2 2001 or later European laser standard FCC 21 CFR Chapter 1 Subchapter J in accordance with FDA CDRH requirements Applicat...

Страница 140: ...wobei die maximale Raumtemperatur 40 C 104 F nicht berschreiten darf Sauber und frei von elektrisch aufladbaren Teilchen in der Luft Ausreichende Bel ftung und Abstand zu W rmequellen einschlie lich...

Страница 141: ...mit internationalen Sicherheitsnormen zu gew hrleisten Nur Stromkabel verwenden die f r den Einsatz in dem jeweiligen Land zugelassen sind Wechselstromkabel d rfen nicht manipuliert werden Die Wandst...

Страница 142: ...Extreme Networks durchzuf hren Der An Aus Schalter des Systems darf nicht die gesamte Stromversorgung zum System unterbrechen Zur Unterbrechung der Wechselstromversorgung zum System m ssen alle Stromk...

Страница 143: ...C14 ausgef hrt sein Die L nge der Stromkabel muss weniger als 5 m 15 Fu betragen Die Mindestspezifikation f r das flexible Kabel lautet Nr 18 AWG 0 823 mm2 f r Einheiten mit einem Bemessungsstrom von...

Страница 144: ...zu beauftragen um die sachgem e Ger teerdung und Stromverteilung f r Ihre spezifische Installation sicherzustellen Austauschen und Entsorgen von Batterien Im Umgang mit Batterien sind folgende Hinwei...

Страница 145: ...Guide 145 Einhaltung beh rdlicher Vorschriften durch GBIC SFP Mini GBIC XENPAK und XFP Laserprodukt der Klasse 1 EN60825 1 A2 2001 oder j nger Europ ische Richtlinie f r Lasersysteme Anwendung der CE...

Страница 146: ...Safety Information BlackDiamond 12800 Series Switches Hardware Installation Guide 146...

Страница 147: ...cm Depth 18 12 inches 46 0 cm Weight BlackDiamond 12804 chassis empty 63 75 lb 29 0 kg BlackDiamond 12804 chassis fully loaded 153 lb 69 5 kg BlackDiamond 12804 power supply 7 lb 3 2 kg BlackDiamond...

Страница 148: ...NZS 3548 ACA Australia Emissions CNS 13438 1997 Class A BSMI Taiwan MIC Mark EMC Approval North Korea Telecom Standards ETSI EN 300 386 2001 EMC Telecommunications ETSI EN 300 019 Environmental for Te...

Страница 149: ...kDiamond 12804 switch with AC Power Supplies Sound power in accordance with EN 300 753 10 1997 Sound power Normal 70 dBA per ISO 7779 High 73 dBA per ISO 7779 Declared sound power Normal 7 2 belsA per...

Страница 150: ...l Immunity IEC EN 61000 4 2 Electrostatic Discharge 8kV Contact 15kV Air Criteria A IEC EN 61000 4 3 Radiated Immunity 10V m Criteria A IEC EN 61000 4 4 Transient Burst 1kV Criteria A IEC EN 61000 4 5...

Страница 151: ...Hz Packaged sinusoidal vibration 5 to 62 Hz 5 mm s velocity 62 to 200 Hz 0 2 G Tilt 22 5 degrees and return to position 14 drops minimum on sides corners 39 4 20 lb 9 kg modules 19 7 80 lb 36 kg chas...

Страница 152: ...ative humidity non condensing Operating altitude 0 m to 3 000 m 0 ft to 9 850 ft Operational shock 30 m s2 3 g 60 shocks Operational office vibration 5 to 100 5 Hz 2 10 G 0 to peak 1 oct min Operation...

Страница 153: ...on 15 A Wire harness provided by Extreme Networks with each power supply Extreme part number 4340 00028 Minimum wire size 14 AWG 1 3 mm2 copper stranded pre approved cord set for county of use Connect...

Страница 154: ...able Pinouts Screen TxD RxD Ground RTS CTS DSR DCD DTR Cable connector 9 pin female Switch Cable connector 25 pin male female 25pin PC Terminal Screen RxD TxD Ground RTS DTR CTS DSR DCD Shell 3 2 5 7...

Страница 155: ...standards 48 BlackDiamond 12800 series switch features 15 MSM 20 BlackDiamond 12802 switch features 18 installing mid mount 67 installing front mount 66 MAC address 18 repacking 129 serial number 18...

Страница 156: ...56 E electrical codes 42 electrostatic discharge See ESD environmental requirements airflow 44 building codes 42 electrical codes 42 humidity 44 switch spacing 44 temperature 43 wiring closet 43 equi...

Страница 157: ...g system for cables 48 LEDs I O modules 24 MSM 21 ports 24 logging in to the switch 70 low line power 34 M MAC address BlackDiamond 12802 switch 18 BlackDiamond 12804 switch 17 management modules MSM...

Страница 158: ...ontroller 116 118 requirements spacing 44 reset button 23 resetting MSM 23 retaining bracket power cord on 325 W AC PSU 97 RF interference patch panel installation 49 preventing 53 problems caused by...

Страница 159: ...1 over current conditions 34 36 85 94 power turning off 34 36 85 RF interference 53 U unshielded twisted pair See UTP UPS uninterruptible power supply 54 UTP cable bend radius 49 category 5 49 dischar...

Страница 160: ...Index BlackDiamond 12800 Series Switches Hardware Installation Guide 160...

Отзывы: