CHRONO SET MENU
21
Chapter 6
CHRONO SET MENU
Controls procedure:
Press key 3 (menu/ok) to access the menu.
Press key 3 (menu/ok) to access the “
USER MENU
”.
Select “
CHRONO SET MENU
” using buttons 4(-) and 5(+) and press key 3 (menu/ok) to confi rm.
The boiler is equipped with a weekly programmer which allows to program 3 time spans within a day to
use every day of the week. The ignition and switch-off times must be within the arc of one day, from 0 to
24 and not over several days:
E.g.
switch-on 07:00 / switch-off 18:00
OK
switch-on 22:00 / switch-off 05:00
ERROR
switch-on 22:00 / switch-off 23:59 OK
PARAMETER
FUNCTION
KEYS
ADJUSTMENT
DISPLAY
CONFIRMATION
KEY
CHRONO ON-OFF
Act./deact. weekly programmer
4(-) o 5(+)
ON/OFF
3(menù/ok)
START PROGRAM 1
Time 1st switch-on
4(-) o 5(+)
OFF or from 00:00 to 23:50
3(menù/ok)
STOP PROGRAM 1
Time 1st switch-off
4(-) o 5(+)
OFF or from 00:00 to 23:50
3(menù/ok)
DAYS ON 1
Consents for 1st switch on/off for various days
4(-) o 5(+)
ON/OFF Monday ... ON/OFF Sunday
3(menù/ok)
START PROGRAM 2
Time 2nd switch-on
4(-) o 5(+)
OFF or from 00:00 to 23:50
3(menù/ok)
STOP PROGRAM 2
Time 2nd switch-off
4(-) o 5(+)
OFF or from 00:00 to 23:50
3(menù/ok)
DAYS ON 2
Consents for 2nd switch on/off for various days
4(-) o 5(+)
ON/OFF Monday ... ON/OFF Sunday
3(menù/ok)
START PROGRAM 3
Time 3rd switch-on
4(-) o 5(+)
OFF or from 00:00 to 23:50
3(menù/ok)
STOP PROGRAM 3
Time 3rd switch-off
4(-) o 5(+)
OFF or from 00:00 to 23:50
3(menù/ok)
DAYS ON 3
Consents for 3rd switch on/off for various days
4(-) o 5(+)
ON/OFF Monday ... ON/OFF Sunday
1(esc)
Let’s suppose that the weekly programmer function is to be used and 3 time periods are to be used in the
following way:
1st time span: from 08:00 to 12:00 every day of the week excluding Saturday and Sunday
2nd time span: from 15:00 to 22:00 only Saturday and Sunday
3rd time span: not used
Let’s set the weekly programmer.
CHRONO ON-OFF
Use buttons 4(-) or 5(+) to activate the weekly programmer by setting the value at
ON
.
To confi rm and continue programming, press button 3 (menu/ok).
START PROGRAM 1
Use buttons 4 or 3 to set “
08:00
”, which corresponds to the switch-on time of the 1st time span.
To confi rm and continue programming, press button 3 (menu/ok).
Press button 2 (set) to go back to the previous parameter.
STOP PROGRAM 1
Use buttons 4(-) or 5(+) to set “
12:00
”, which corresponds to the switch-on time of the 1st time span. To
confi rm and continue programming, press button 3 (menu/ok).
Press button 2 (set) to go back to the previous parameter.