ENGLISH
Control panel
BUTTON
ON/OFF
Display OF variOUs
TexT messages
Display
OF pOwer
TemperaTUre seTTiNg
OperaTiON pOwer
aDJUsTmeNT
Display iCons key
indicates the presence of an alarm.
On: indicates the presence of an alarm
Off: indicates the absence of alarms
Flashing: indicates the deactivation of the depression
sensor.
it indicates weekly programming functioning
indicator on = weekly programming active
indicator off = weekly programming disabled
indicates the room temperature status
Off = the T° read by the probe is above the set temperature
On = the T° read by the probe is below the set temperature
indicates the stby function
Off = stby deactivated
On = stby activated
ignition plug
Off = ignition plug active
On = ignition plug deactivated
Flashing = ignition phase
additional external thermostat input status
Off = open contact
On = closed contact
it indicates fumes motor operation.
Off = fumes motor not working
On = fumes motor working
Flashing = breakdown
it indicates the communication between remote control
and stove. every time a key is pressed on the remote control
the indicator must switch on. if the indicator is always on it
indicates that the communication between remote control
and stove is blocked.
*
1
it indicates functioning of the tangential fan
Off = not working
On = working
Not used
2
Not used
additional ducted thermostat input status:
On = closed contact (to be satisfied)
Flashing = the motor is running at minimum and in
modulation mode (input=open)
it indicates pellet feed motor operation
Off = pellet feed motor disabled
On = pellet feed motor active