HOT AIR DUCTING
The pipe used for ducting the hot air must have an internal diameter of 80 mm, be insulated and protected against heat loss.
INsTAllATION Of THe RelevANT pIpes UseD fOR DUCTING THe HOT AIR mUsT be peRfORmeD by
qUAlIfIeD sTAff AND/OR THe mANUfACTUReR's TeCHNICAl AfTeR-sAles AssIsTANCe
sOUveNIR AND IleNIA spACeRs
Models “SOUVENIR” and "ILENIA" feature 4 spacers at the back which delimit the minimum distance to be maintained from any
rear support.
The spacers must not be removed.
elIsIR
The “Elisir” model can be ducted at the back, to the side or at the top, for further details
relating to installation, refer to the instruction sheet included in the machine.
It is possible to use single ducting as required.
Features:
ducting outlet diameter: 80 mm
maximum recommended ducting length 6m
possibility to thermostat the ducting via an additional thermostat (option)
possibility to adjust the ventilation speed in percentage, ducting cannot be excluded.