background image

25

Log into the Web Interface 

Once you have determined the receiver’s IP address, enter it into a browser to carry out configuration.

1

2

Admin – log in using: 

username: 

admin

password: 

labrador

 

to access the Web Admin 
Interface.

Note that the Status page is 
first displayed when you log 
in to the receiver.

Enter the IP address 
of the receiver

Содержание avediaplayer R93 series

Страница 1: ...Exterity AvediaPlayer Receiver r93xx Series V5 0 Getting Started Guide...

Страница 2: ...er trademarks are the property of their respective owners All rights reserved Disclaimer The information contained in this document is subject to change without notice EXTERITY LIMITED MAKES NO WARRAN...

Страница 3: ...diaPlayer r9300 Receiver 10 AvediaPlayer r9310 Receiver 11 2 Before You Begin 12 Network Considerations 12 Physical Location 13 Power 13 User Control 14 3 Connection and Power On 15 Connect the AV Out...

Страница 4: ...dress 21 Using AvediaServer Director 22 Using the Connected TV and Remote Handset 23 Using the Serial Admin Interface 24 Log into the Web Interface 25 Assigning a Static IP Address 26 Using the Serial...

Страница 5: ...in this manual 8 Do not install near any heat sources such as radiators heat registers stoves or other apparatus including amplifiers that produce heat 9 Do not defeat the safety purpose of the polari...

Страница 6: ...is apparatus to dripping or splashing and ensure that no objects filled with liquids such as vases are placed on the apparatus 16 To completely disconnect this apparatus from the AC Mains disconnect t...

Страница 7: ...blocked Keep all materials at least 5cm away from all the ventilation holes Do not expose the product to any rain or moisture Do not use the product near a naked flame e g a candle The operating cond...

Страница 8: ...rator s Guide for information about the configuration and use of the remote control handset Scope This manual describes the installation connection and initial configuration of AvediaPlayer r93xx Rece...

Страница 9: ...ant for the proper operation of the product Courier Font is used to identify scripts code examples or keyboard commands SMALL CAPITALS are used to indicate Remote Control handset buttons and button pr...

Страница 10: ...ms from third party products Models AvediaPlayer r93xx Receivers provide the following AV outputs Video HDMI v1 4b with HDCP 1080p 1080i 720p 50Hz 59 94Hz 60Hz 576p 576i 50Hz 480p 480i 59 94Hz 60Hz Au...

Страница 11: ...de support for Video HDMI v1 4b with HDCP 1080p 1080i 720p 50Hz 59 94Hz 60Hz 576p 576i 50Hz 480p 480i 59 94Hz 60Hz Audio HDMI 2 or 6 channel PCM or Bitstream TOS 2 channel PCM or Bitstream Component Y...

Страница 12: ...GMP snooping One switch must act as the IGMP querier Exterity Receivers support version 2 and 3 of IGMP The Ethernet port a 10 100 Mbps interface used to connect the receiver to the network switch usi...

Страница 13: ...Exterity sales representative for details of the available AvediaPlayer r93xx Receiver installation accessories Please see the Exterity Accessories Datasheet for details of order codes PoE The receive...

Страница 14: ...eration of IR remote control may be impaired by strong IR sources such as sunlight certain fluorescent lighting types and displays For consistent operation the IR receiver extender body may require sh...

Страница 15: ...te You must use HDMI compliant cables to connect the receiver to the display device Tip For best performance Exterity recommends the addition of a ferrite on the HDMI cable A Wurth 742 716 22 S or sim...

Страница 16: ...osite Analog Audio Component Video HD and SD Use standard phono cables RCA Composite Video SD only Use a standard phono cable RCA Analog Audio Analog audio 1 volt peak to peak maximum Use standard pho...

Страница 17: ...nnect the 2 channel PCM or Bitstream audio output to an external audio system if required Not required if using HDMI HDMI Use HDMI cables to attach an external audio system between the receiver and th...

Страница 18: ...e all rear panel LEDs turn on as soon as the connection is made The front panel LED behaves as described in During Power On on page 19 Without PoE connect the DC supply as described below DC Supply Po...

Страница 19: ...ands as follows Function LED activity Startup Remains off for around 10 seconds then on for around 20 30 seconds with periods of rapid flickering Followed by IP address acquisition Acquiring IP addres...

Страница 20: ...onfigure basic device capabilities and to troubleshoot problems Refer to Using the Serial Admin Interface on page 24 For more details on using this interface refer to the AvediaPlayer r93xx Receiver A...

Страница 21: ...the receiver s IP address is allocated automatically If you are using AvediaServer Director you can then access the receiver directly as shown in Using AvediaServer Director If you do not have access...

Страница 22: ...o access the Web Admin Interface Director lists all Exterity devices in your network Find the device using its MAC address Click the receiver s name to open its web interface Enter the IP address of t...

Страница 23: ...he television screen click the MODE button on the handset Scroll down the displayed options and select Network Network DHCP Enabled IP address 18 9 199 22 Network mask 255 255 0 0 Gateway 18 9 64 1 Se...

Страница 24: ...below Admin log in using username admin password labrador to access the Serial Admin Interface Enter 3 to view the current IP address of the receiver USB Serial Serial port RJ45 Exterity access usb R...

Страница 25: ...s IP address enter it into a browser to carry out configuration 1 2 Admin log in using username admin password labrador to access the Web Admin Interface Note that the Status page is first displayed w...

Страница 26: ...the receiver as shown below 1 2 Terminal Program such as PuTTY Baud rate 115200 Data bits 8 Parity none Stop bits 1 Flow control none Admin log in using username admin password labrador to access the...

Страница 27: ...d password admin labrador 2 Click Network Figure 1 Setting a static IP address using the receiver s web interface 3 In the IP Address Configuration section select Static 4 Enter the required values fo...

Страница 28: ...multiple receivers are deployed in a hospitality installation you can use the room number and floor as the name and location To configure the device s name and location using the web management interf...

Страница 29: ...ress assigned to the receiver Hardware Type The exact type of hardware module including the hardware revision and daughtercard type For example the hardware type could be shown as AVR Tom B 3 MOR C 1...