background image

7

 

TM500-EU-EN v1.1   12/13

 

Measurements

 

and

 

related

 

features

 

Basic

 

Thermocouple

 

Mode

 

Thermocouples

 

are

 

connected

 

at

 

the

 

top

 

of

 

the

 

meter

 

to

 

the

 

jacks

 

labeled

 

T1

 

through

 

T12.

 

Select

 

the

 

thermocouple

 

type

 

(J,

 

K,

 

etc.)

 

to

 

match

 

the

 

thermocouple

 

type

 

used.

 

In

 

normal

 

thermocouple

 

mode

 

the

 

meter

 

will

 

simultaneously

 

display

 

the

 

temperature

 

for

 

thermocouples

 

T1

 

through

 

T12.

 

Dashes

 

are

 

displayed

 

if

 

a

 

thermocouple

 

is

 

not

 

connected

 

or

 

if

 

the

 

measurement

 

is

 

out

 

of

 

range.

 

Data

 

Hold

  

To

 

freeze

 

a

 

measurement

 

on

 

the

 

display,

 

press

 

the

 

HOLD

 

button

 

momentarily.

 

The

 

meter

 

will

 

emit

 

a

 

beep,

 

the

 

reading

 

will

 

hold,

 

and

 

the

 

HOLD

 

icon

 

will

 

switch

 

on.

 

Press

 

the

 

HOLD

 

button

 

again

 

to

 

release

 

the

 

display

 

and

 

exit

 

the

 

Data

 

Hold

 

mode

 

returning

 

the

 

meter

 

to

 

the

 

normal

 

operating

 

mode.

 

Temperature

 

Display

 

OFFSET

 

The

 

VPC300

 

allows

 

the

 

user

 

to

 

set

 

a

 

display

 

offset

 

that

 

applies

 

to

 

all

 

of

 

the

 

thermocouple

 

displays

 

equally.

 

To

 

set

 

the

 

display

 

offset

 

follow

 

the

 

steps

 

below:

 

1. Press

 

and

 

hold

 

the

 

OFFSET

 

button

 

for

 

3

 

seconds

 

to

 

reach

 

the

 

offset

 

screen.

 

The

 

temperature

 

on

 

the

 

left

 

is

 

the

 

currently

 

displayed

 

temperature

 

for

 

Channel

 

1

 

and

 

the

 

temperature

 

on

 

the

 

right

 

is

 

the

 

offset

 

temperature

 

2. Use

 

the

 

up

 

and

 

down

 

arrow

 

keys

 

to

 

adjust

 

the

 

display

 

on

 

the

 

right

 

to

 

offset

 

the

 

display

 

as

desired.

 

3. When

 

finished,

 

press

 

the

 

ENTER

 

button

 

to

 

store

 

the

 

offset

 

and

 

return

 

to

 

normal

 

operation.

4. All

 

of

 

the

 

thermocouple

 

readings

 

will

 

now

 

reflect

 

the

 

offset

 

value

 

programmed

 

by

 

the

user.

 

To

 

clear

 

the

 

OFFSET,

 

follow

 

the

 

steps

 

below:

 

1. Switch

 

the

 

meter

 

power

 

OFF

2. Press

 

and

 

hold

 

the

 

HOLD

 

and

 

REC

 

buttons

 

while

 

switching

 

the

 

meter

 

power

 

ON

3. Release

 

the

 

two

 

buttons

 

when

 

the

 

meter

 

switches

 

ON

4. Press

 

and

 

hold

 

the

 

OFFSET

 

button

 

for

 

5

 

seconds

 

and

 

the

 

display

 

will

 

show

 

CODE

 

100

5. Use

 

the

 

up

 

arrow

 

button

 

to

 

change

 

from

 

CODE

 

100

 

to

 

CODE

 

125

 

and

 

then

 

press

 

ENTER

6. Use

 

the

 

arrow

 

buttons

 

to

 

select

 

YES

 

or

 

NO

 

and

 

then

 

press

 

ENTER

7. If

 

YES

 

is

 

selected,

 

the

 

meter

 

will

 

clear

 

the

 

previously

 

programmed

 

offset.

 

If

 

NO

 

is

 

selected,

the

 

meter

 

will

 

retain

 

the

 

offset

 

programmed

 

by

 

the

 

user.

MAX

MIN

 

Readings

 

For

 

a

 

given

 

measurement

 

session,

 

this

 

meter

 

can

 

record

 

the

 

highest

 

(MAX)

 

and

 

the

 

lowest

 

(MIN)

 

readings

 

for

 

later

 

recall.

 

1.

Press

 

the

 

REC

 

button

 

momentarily

 

to

 

access

 

this

 

mode

 

of

 

operation

 

(REC

 

icon

 

appears)

 

2.

The

 

meter

 

is

 

now

 

recording

 

the

 

MAX

 

and

 

MIN

 

readings.

 

3.

Press

 

the

 

REC

 

button

 

again

 

to

 

view

 

the

 

current

 

MAX

 

readings

 

(MAX

 

icon

 

appears).

 

The

readings

 

on

 

the

 

display

 

are

 

now

 

the

 

highest

 

readings

 

encountered

 

since

 

the

 

REC

 

icon

 

was

netzerotools.com

netzerotools.com

Содержание TM500

Страница 1: ...USER GUIDE 12 Channel Thermocouple Datalogger Model TM500 netzerotools com netzerotools com netzerotools com Extech TM500 12 Channel Thermocouple Datalogger Type J K E T R S ...

Страница 2: ...per use will provide years of reliable service Please visit the Extech Instruments website to check for the latest version of this User Guide Meter Description 1 Thermocouple inputs 2 DC power adapter SD memory slot and PC interface jack 3 Power ON OFF and Backlight key 4 HOLD and NEXT key 5 Power ON OFF and ESC key 6 REC and ENTER 7 TYPE key K J T R E or S 8 LOGGER Offset key 9 SET Time Check key...

Страница 3: ... that the adaptor is connected correctly to the meter and to an AC source refer to the AC Power Adaptor section later in this guide Connecting Thermocouple Sensors This meter can accept Thermocouple temperature probe Types K J T E R or S Connect up to twelve 12 thermocouples to the sub miniature jacks at the top of the meter labeled T1 through T12 Select the desired mode of operation and other set...

Страница 4: ...nds 5 The available Setup parameters are listed below Additional detailed information is provided below this list dAtE Set the clock Year Month Date Hours Minutes Seconds LooP Start and End a loop measurement cycle dEC Set the numerical format USA decimal 20 00 or European comma 20 00 PoFF Automatic power off Enable or disable the auto power off function bEEP Set the beeper sound ON OFF t CF Selec...

Страница 5: ... is used to separate units from tenths i e 20 00 The European format uses a comma i e 20 00 to separate units from tenths To change this setting 1 Access the dEC parameter 2 Use the arrow buttons to select USA or EUro Press ENTER to confirm setting 3 Press the ENTER button to exit to the Setup mode Press ESC to exit setup mode Setting Poff Enabling Disabling the Auto Power OFF Feature 1 Access the...

Страница 6: ... and 3600 seconds Use 0 for manual logging mode A sampling rate 1 second is recommended 3 Press the ENTER button to confirm the entry 4 Press the ENTER button to exit to the Setup mode Press ESC to exit setup mode SD Card FORMATTING 1 Access the Sd F parameter 2 Use the arrow buttons to select YES to format the card select NO to abort Note that all data on the card will be lost if formatting is at...

Страница 7: ...re 2 Use the up and down arrow keys to adjust the display on the right to offset the display as desired 3 When finished press the ENTER button to store the offset and return to normal operation 4 All of the thermocouple readings will now reflect the offset value programmed by the user To clear the OFFSET follow the steps below 1 Switch the meter power OFF 2 Press and hold the HOLD and REC buttons ...

Страница 8: ...the display backlight ON or OFF press the backlight button momentarily The meter will beep when switching the backlight ON or OFF unless the beeper is disabled as described in the Setup Mode section of this user guide Time Check Momentarily press the SET button and the meters current Date and Time will appear in the lower left corner of the display Sampling Time Check When in normal mode press the...

Страница 9: ...d the logger s clock set to allow for accurate date time stamping during datalogging sessions Refer to the Setup Mode section for SD card formatting and time date setting instructions European and USA numerical formats differ The data on the SD card can be formatted for either format The meter defaults to USA mode where a decimal point is used to separate units from tenths i e 20 00 The European f...

Страница 10: ... 5 To pause the datalogger press the LOGGER button momentarily The DATALOGGER and REC icons will stop flashing To resume logging simply press the LOGGER button again momentarily 6 To terminate the datalogging session press the LOGGER button to stop the logging and then press the REC button for at least 1 5 seconds 7 When an SD card is used for the first time a folder is created on the card and nam...

Страница 11: ...cal datalogging 2 With the meter switched OFF remove the SD Card 3 Plug the SD Card directly into a PC SD card reader If the PC does not have an SD card slot use an SD card adaptor available at most outlets where computer accessories are sold 4 Power the PC and run a spreadsheet software program Open the saved documents in the spreadsheet software program see example spreadsheet data screens below...

Страница 12: ...ing polarity Replace the battery compartment cover with the two 2 Phillips screws Battery Safety Reminders Never dispose of batteries in a fire Batteries may explode or leak Never mix battery types Always install new batteries of the same type As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherev...

Страница 13: ...ss on slower computers Memory Card SD memory card 1G to 16GB size Temperature Compensation Automatic compensation for all thermocouple types Display update rate Approx 1 second Data Output RS 232 USB PC computer interface 9600 N 8 1 Operating Temperature 0 to 50 C 32 to 122 F Operating Humidity 85 R H maximum Auto Power OFF After 10 minutes of inactivity can be disabled Power Supply Eight 8 1 5 VD...

Страница 14: ...o 999 9 C 0 4 0 5 C 1 C 1000 to 1300 C 0 4 1 C 0 1 F 148 0 to 58 1 F 0 4 1 8 F 58 0 to 999 9 F 0 4 1 F 1 F 1000 to 2372 F 0 4 2 F Type J 0 1 C 100 0 to 50 1 C 0 4 1 C 50 0 to 999 9 C 0 4 0 5 C 1 C 1000 to 1150 C 0 4 1 C 0 1 F 148 0 to 58 1 F 0 4 1 8 F 58 0 to 999 9 F 0 4 1 F 1 F 1000 to 2102 F 0 4 2 F Type T 0 1 C 100 0 to 50 1 C 0 4 1 C 50 0 to 400 0 C 0 4 0 5 C 0 1 F 148 0 to 58 1 F 0 4 1 8 F 58...

Отзывы: