background image

TM100-EU-EN v1.3   12/13 

Replacing the Batteries 

1. 

Switch OFF the thermometer. 

2. 

Loosen the battery compartment screw and remove the compartment door. 

3. 

Replace the AAA batteries. 

4. 

Replace the battery door and tighten the screw. 
 

Never dispose of used batteries or rechargeable batteries in household waste. 
As consumers, users are legally required to take used batteries to appropriate 
collection sites, the retail store where the batteries were purchased, or wherever 
batteries are sold. 

Disposal: 

Do not dispose of this instrument in household waste. The user is obligated to take end-of-

life devices to a designated collection point for the disposal of electrical and electronic equipment.  
 

Other Battery Safety Reminders 

o

  Never dispose of batteries in a fire. Batteries may explode or leak.

 

o

  Never mix battery types. Always install new batteries of the same type.

 

 

Specifications 

Temperature Range: 

K type thermocouples 

-200°C to 1372°C (-328°F to 2501°F) 

J type thermocouples 

-210°C to 1100°C (-346°F to 2012°F) 

Note that thermocouple wire may be insulated with materials that cannot withstand temperatures 

in the ranges listed above. Check that the thermocouples used are rated for the temperature 

measurements to be made.  
 

Temperature accuracy: 

T1   Above –100 °C (-148 °F) 

 ± [0.15%rgd+1°C (1.8°F)] 

T1   Below –100 °C (-148 °F) 

± [0.5%rgd+2°C (3.6°F)] 

Display Resolution: 

0.1°C /°F /°K <1000, 1°C /°F /°K >1000  

Power supply: 

Three (3) AAA 1.5V batteries 

Operating Temperature:  

0°C to 

50°C (40°F to 

122°F)    

Storage Temperature: 

10°C to 

50°C (14°F to 

122°F) 

Dimensions: 

220 x 63 x 28mm (8.7 x 2.5 x 1.1”) 

Weight:  

200g (7oz) 

 

 

 

 

 

  

Shop for Extech products at:

1.888.610.7664

ShopExtech

.com

Содержание TM100

Страница 1: ...User s Guide Digital J K Type Thermometer Model TM100 Shop for Extech products at 1 888 610 7664 ShopExtech com ...

Страница 2: ...tech com to check for the latest version of this User Guide Product Updates and Customer Support Safety To prevent personal injury or meter damage use the meter only as specified in this guide Description Meter 1 Thermocouple input connector 2 Function buttons Power Enter C F K 3 Function buttons Hold MAX MIN Set 4 LCD display 5 Battery compartment Display 1 Setup 2 Offset option 3 Hold mode 4 Aut...

Страница 3: ...play indicates OL the temperature is outside the measurement range The display shows when a thermocouple is not connected MAX MIN AVG mode Press MAX MIN to capture and step through the maximum MAX minimum MIN and average AVG temperature values These values will be shown in the lower display with an elapsed time reference below hrs mins mins secs 1 Press MAX MIN to enter this mode 2 Press MAX MIN t...

Страница 4: ...ter 20 minutes of inactivity no buttons pressed When the thermometer is in Setup mode the display shows the SETUP display icon 1 Press or to scroll to the SLP setting 2 Press ENTER to choose the option On or OFF will appear in the display 3 Use the arrow key to select ON or OFF 4 Press ENTER to store the new setting 5 Press and hold the SET button for 3 seconds to return to normal mode Set Offset ...

Страница 5: ...ty Reminders o Never dispose of batteries in a fire Batteries may explode or leak o Never mix battery types Always install new batteries of the same type Specifications Temperature Range K type thermocouples 200 C to 1372 C 328 F to 2501 F J type thermocouples 210 C to 1100 C 346 F to 2012 F Note that thermocouple wire may be insulated with materials that cannot withstand temperatures in the range...

Отзывы: