background image

SL10-en-GB_V1.2   4/15 

Specifications 

Display 

4-digit (4000 count) backlit LCD

 

Display update rate 

0.5 seconds 

Microphone 

0.5” Electret condenser 

Measurement 
Bandwidth 

31.5Hz to 8KHz

 

Measurement Range 

40 to 130dB 

Frequency weighting 

‘A’ (dBA) 

Accuracy / Resolution  ± 3.5dB (under 94dB reference conditions) / 

0.1dB 

Response time 

125 milliseconds 

Power 9V 

Battery

 

Battery life 

50 hours (typical); low battery indicator alerts 
user 

Automatic power off 

After approx. 15 minutes of inactivity 

Operating 
temperature 

32 to 104

o

F (0 to 40

o

C) 

Operating humidity 

10 to 90% RH 

Storage temperature 

14 to 140

o

F (-10 to 60

o

C) 

Storage humidity 

10 to 75% RH 

Dimensions/weight 

8.3 x 2.2 x 1.3” (210 x 55 x 32mm) / 4.8oz 
(135g)

 

Approvals CE 

 

 
 
 
 
 

Copyright

 

©

 

2013

 ‐ 

2015

 

FLIR

 

Systems,

 

Inc.

 

All

 

rights

 

reserved

 

including

 

the

 

right

 

of

 

reproduction

 

in

 

whole

 

or

 

in

 

part

 

in

 

any

 

form

 

ISO

9001

 

Certified

 

www.extech.com

 

 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание SL10

Страница 1: ...User s Guide Personal Sound Level Meter Model SL10 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com ...

Страница 2: ... following safety information carefully before attempting to operate or service the meter Use the meter only as specified in this manual otherwise the protection provided by the meter may be impaired Environmental Conditions Altitude up to 2000 meters Relative Humidity 90 max Operating Temperature 32 to 104o F 0 to 40o C Maintenance and Cleaning Repair or servicing not covered in this manual shoul...

Страница 3: ...s the noise measurement Use the supplied windscreen to cover the microphone when applicable 2 Calibrate the instrument before each use if possible Especially if the meter has not been used for a long period of time 3 Do not store or operate the instrument in areas of high temperature or humidity 4 Keep meter and microphone dry 5 Avoid severe vibration 6 Remove the battery when the meter is to be s...

Страница 4: ...larm OVER If the measurement exceeds 130 dB the display indicates OVER To avoid damage to the meter do not continue to use the meter in an environment where the sound measured exceeds 130dB MAX MIN HOLD In this mode the meter only updates the LCD reading when a higher reading MAX mode or lower reading MIN mode is detected Select MAX HOLD by momentarily pressing the MAX MIN button The meter display...

Страница 5: ...s typical low battery indicator alerts user Automatic power off After approx 15 minutes of inactivity Operating temperature 32 to 104o F 0 to 40o C Operating humidity 10 to 90 RH Storage temperature 14 to 140o F 10 to 60o C Storage humidity 10 to 75 RH Dimensions weight 8 3 x 2 2 x 1 3 210 x 55 x 32mm 4 8oz 135g Approvals CE Copyright 2013 2015 FLIR Systems Inc All rights reserved including the ri...

Отзывы: