Manual

 

Datalogging

 

In

 

the

 

manual

 

mode

 

the

 

user

 

presses

 

the

 

LOG

 

button

 

to

 

manually

 

log

 

a

 

reading

 

onto

 

the

 

SD

 

card.

 

1.

 

Set

 

the

 

sampling

 

rate

 

to

 

‘0’

 

seconds

 

as

 

described

 

in

 

the

 

Setup

 

Mode

 

section.

 

2.

 

Press

 

and

 

hold

 

the

 

LOG

 

button

 

for

 

at

 

least

 

1.5

 

seconds

 

and

 

the

 

DATALOGGER

 

icon

 

will

 

appear

 

on

 

the

 

LCD;

 

the

 

lower

 

portion

 

of

 

the

 

display

 

will

 

show

 

p

n

 

(

n

 

=

 

memory

 

position

 

number

 

1

99).

 

Note

 

that

 

if

 

PSI

 

is

 

set

 

as

 

the

 

unit

 

of

 

measure

 

it

 

appears

 

as

 

P51

 

(where

 

a

 

‘5’

 

is

 

used

 

as

 

an

 

‘S’)

 

in

 

the

 

same

 

area

 

of

 

the

 

LCD

 

where

 

memory

 

locations

 

are

 

shown.

 

This

 

can

 

be

 

disorienting

 

at

 

first.

 

3.

 

Momentarily

 

press

 

the

 

LOG

 

button

 

to

 

store

 

a

 

reading.

 

The

 

DATALOGGER

 

icon

 

will

 

flash

 

and

 

the

 

beeper

 

will

 

sound

 

(if

 

set

 

to

 

ON)

 

each

 

time

 

a

 

data

 

point

 

is

 

stored.

 

4.

 

Use

 

the

 

 

and

 

 

buttons

 

to

 

select

 

one

 

of

 

the

 

99

 

data

 

memory

 

positions

 

in

 

which

 

to

 

record.

   

5.

 

To

 

exit

 

the

 

manual

 

datalogging

 

mode,

 

press

 

and

 

hold

 

the

 

LOG

 

button

 

for

 

at

 

least

 

1.5

 

seconds.

 

The

 

DATALOGGER

 

icon

 

will

 

switch

 

off.

 

Automatic

 

Datalogging

 

In

 

automatic

 

datalogging

 

mode

 

the

 

meter

 

takes

 

and

 

stores

 

a

 

reading

 

at

 

a

 

user

specified

 

sampling

 

rate

 

onto

 

an

 

SD

 

memory

 

card.

 

The

 

meter

 

defaults

 

to

 

a

 

sampling

 

rate

 

of

 

two

 

seconds.

 

To

 

change

 

the

 

sampling

 

rate,

 

refer

 

to

 

the

 

Setup

 

Mode

 

section

 

(the

 

sampling

 

rate

 

cannot

 

be

 

‘0’

 

for

 

automatic

 

datalogging):

 

1.

 

Select

 

the

 

sampling

 

rate

 

in

 

the

 

Setup

 

Mode

 

to

 

a

 

value

 

other

 

than

 

zero.

 

2.

 

Press

 

and

 

hold

 

the

 

LOG

 

button

 

for

 

at

 

least

 

1.5

 

seconds.

 

The

 

meter

 

will

 

flash

 

the

 

DATALOGGER

 

icon

 

at

 

the

 

selected

 

sampling

 

rate

 

indicating

 

that

 

readings

 

are

 

now

 

being

 

automatically

 

recorded

 

to

 

the

 

SD

 

card.

 

3.

 

If

 

a

 

card

 

is

 

not

 

inserted

 

or

 

if

 

the

 

card

 

is

 

defective,

 

the

 

meter

 

will

 

display

 

EMPTY

 

and

 

exit

 

the

 

DATALOGGER

 

mode.

 

In

 

this

 

case,

 

switch

 

the

 

meter

 

OFF

 

and

 

try

 

again

 

with

 

a

 

valid

 

SD

 

card.

 

4.

 

Pause

 

the

 

datalogger

 

by

 

pressing

 

the

 

LOG

 

button

 

momentarily.

 

The

 

DATALOGGER

 

icon

 

will

 

stop

 

flashing

 

and

 

the

 

sample

 

rate

 

will

 

display

 

for

 

a

 

short

 

time.

 

To

 

resume

 

logging

 

simply

 

press

 

the

 

LOG

 

button

 

again

 

momentarily.

 

5.

 

To

 

terminate

 

the

 

datalogging

 

session

 

press

 

and

 

hold

 

the

 

LOG

 

button

 

for

 

at

 

least

 

1.5

 

seconds.

 

6.

 

When

 

an

 

SD

 

card

 

is

 

used

 

for

 

the

 

first

 

time

 

a

 

folder

 

is

 

created

 

on

 

the

 

card

 

and

 

named

 

PMA01

.

 

Up

 

to

 

99

 

spreadsheet

 

documents

 

(each

 

with

 

30,000

 

readings)

 

can

 

be

 

stored

 

in

 

this

 

folder.

 

7.

 

When

 

datalogging

 

begins

 

a

 

new

 

spreadsheet

 

document

 

named

 

PMA01001.xls

 

is

 

created

 

on

 

the

 

SD

 

card

 

in

 

the

 

PMA01

 

folder.

 

The

 

data

 

recorded

 

will

 

be

 

placed

 

in

 

the

 

PMA01001.xls

 

document

 

until

 

30,000

 

readings

 

are

 

reached.

 

8.

 

If

 

the

 

measurement

 

session

 

exceeds

 

30,000

 

readings,

 

a

 

new

 

document

 

will

 

be

 

created

 

(PMA01002.xls)

 

where

 

another

 

30,000

 

readings

 

can

 

be

 

stored.

 

This

 

method

 

continues

 

for

 

up

 

to

 

99

 

documents,

 

after

 

which

 

another

 

folder

 

is

 

created

 

(PMA02)

 

where

 

another

 

99

 

spreadsheet

 

documents

 

can

 

be

 

stored.

 

This

 

process

 

continues

 

in

 

this

 

same

 

fashion

 

with

 

folders

 

PMA03

 

through

 

PMA10

 

(last

 

allowable

 

folder).

 

Содержание SDL730

Страница 1: ...User Manual Heavy Duty Differential Pressure Manometer Model SDL730 Additional User Manual Translations available at www extech com ...

Страница 2: ...User Guide and Customer Support Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Meter Description 1 P1 Input positive 2 P2 Input negative 3 LCD Display 4 HOLD and Backlight key 5 MAX MIN key 6 SET and Clock key 7 RS232 output jack 8 Reset button 9 Power Adaptor jack 10 SD card slot 11 ENTER a...

Страница 3: ...er is disabled Units of Measure The currently selected unit of measure is shown below the measurement value on the meter s LCD To change the unit of measure press and hold the UNIT button until the desired unit of measure appears and then release the UNIT button The meter begins scrolling through the available units of measure see table below after the UNIT button has been depressed for at least 1...

Страница 4: ...ormation is provided below this list dAtE Set the clock Year Month Date Hours Minutes Seconds SP t Set the datalogger sampling rate Hours Minutes Seconds PoFF Automatic power off management Enable or disable the auto power off function bEEP Set the beeper sound ON OFF dEC Set the numerical format USA decimal 20 00 or European comma 20 00 SdF Format the SD memory card Setting the Clock Time 1 Acces...

Страница 5: ...ait 7 seconds for the meter to automatically switch to the normal operating mode Numerical Format comma or decimal European and USA numerical formats differ The meter defaults to USA mode where a decimal point is used to separate units from tenths i e 20 00 The European format uses a comma i e 20 00 to separate units from tenths To change this setting 1 Access the dEC parameter 2 Use the arrow but...

Страница 6: ...dings encountered since the REC icon was switched on when the MAX MIN button was first pressed 5 To exit the MAX MIN mode press and hold the MAX MIN button for at least 1 5 seconds The meter will beep the REC MAX MIN icons will switch off the MAX MIN memory will clear and the meter will return to the normal operating mode Fittings Connection Connect tubing to the P1 P2 or both input port s If both...

Страница 7: ... change the sampling rate refer to the Setup Mode section the sampling rate cannot be 0 for automatic datalogging 1 Select the sampling rate in the Setup Mode to a value other than zero 2 Press and hold the LOG button for at least 1 5 seconds The meter will flash the DATALOGGER icon at the selected sampling rate indicating that readings are now being automatically recorded to the SD card 3 If a ca...

Страница 8: ...d 3 Plug the SD Card directly into a PC SD card reader If the PC does not have an SD card slot use an SD card adaptor available at most outlets where computer accessories are sold 4 Power the PC and run a spreadsheet software program Open the saved documents in the spreadsheet software program see example spreadsheet data screen below Spreadsheet data example AC Power Adaptor This meter is normall...

Страница 9: ...9 SDL730 en GB_V1 0 12 16 Hose Couplings This meter is supplied with a pair of hose couplings They fit 4 0mm 0 157 tubing See diagram on how to connect these couplings to the hose and the meter ...

Страница 10: ...orrect polarity Replace the battery compartment cover with the two 2 Phillips screws Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household wast...

Страница 11: ...in 59 sec Data lose may occur when logging at a 1 second rate MANUAL LOGGING Set the sampling rate to 0 seconds Select 1 to 99 locations Data error number 0 1 number of total saved data Memory Card SD memory card 1G to 16GB size Data Hold Freeze the displayed reading Memory Recall Record and Recall the Maximum and Minimum readings Display update rate Approx 1 second Operating Temperature 0 to 50 C...

Страница 12: ... 1 700 0 kPa 0 5 7000 hPA 5 2810 inches H2O 2 71 35 m H2O 0 05 6 905 ATP 0 005 Conversions Useful conversion Factors From To Multiplier in of H2O in of Hg 0 07355 in of H2O cm of H2O 2 54 mm of Hg in of H2O 0 53524 Copyright 2016 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www extech com ...

Отзывы: