Specifications

 

General

 

Specifications

 

Display

 

Backlit

 

LCD;

 

LCD

 

size:

 

51

 

x

 

37mm

 

(2

 

x

 

1.5”)

 

Status

 

indicators

 

Over

range

 

audible

 

beep

 

and

 

low

 

battery

 

display

 

icon

 

 

Measurement

 

Units

 

mBar,

 

psi,

 

Kg/cm

2

,

 

hPA,

 

mm

 

Hg,

 

inch

 

Hg,

 

meters

 

H

2

O,

 

kPA,

 

inches

 

H

2

O,

 

ATP

 

Accuracy

 

(Meter)

 

±

 

(2%FS)

 

at

 

ambient

 

temperature

 

23°C

 

 

5°C)

 

Input

 

circuit

 

Differential

 

inputs

 

(P1

 

+

 

and

 

P2

 ‐

)

 

Input

 

Ports

 

Two

 

metal

 

5.0mm

 

(0.197”),

 

barbed

 

for

 

4.0mm(0.157”)

 

ID

 

tubing

 

Hose

 

couplings

 

Replacement

 

pair

 

of

 

hose

 

couplings

 

(407915)

 

Sensor

 

Built

in

 

piezoelectric

 

sensors

 

Datalogger

 

Sampling

 

Rate

 

AUTO

 

LOGGING:

 

From

 

1

 

second

 

up

 

to

 

8

 

hours

 

59

 

min

 

59

 

sec.

 

(Data

 

lose

 

may

 

occur

 

when

 

logging

 

at

 

a

 

1

 

second

 

rate)

 

 

MANUAL

 

LOGGING:

 

Set

 

the

 

sampling

 

rate

 

to

 

‘0’

 

seconds.

 

Select

 

1

 

to

 

99

 

locations.

 

Data

 

error

 

number

 

≤ 

0.1%

 

number

 

of

 

total

 

saved

 

data

 

Memory

 

Card

 

SD

 

memory

 

card;

 

1G

 

to

 

16GB

 

size

 

Data

 

Hold

 

Freeze

 

the

 

displayed

 

reading

 

Memory

 

Recall

 

Record

 

and

 

Recall

 

the

 

Maximum

 

and

 

Minimum

 

readings

 

Display

 

update

 

rate

 

Approx.

 

1

 

second

 

Operating

 

Temperature

 

0

 

to

 

50°C

 

(32

 

to

 

122°F)

 

Operating

 

Humidity

 

85%

 

R.H.

 

max.

 

Auto

 

Power

 

OFF

 

 

After

 

10

 

minutes

 

of

 

inactivity

 

(can

 

be

 

disabled)

 

Power

 

Supply

 

Six

 

(6)

 

1.5

 

VDC

 

batteries

 

(optional

 

9V

 

AC

 

adaptor)

 

Power

 

Consumption

 

Normal

 

operation

 

(backlight

 

and

 

datalogger

 

OFF):

 

approx.

 

7mAdc

 

 

With

 

backlight

 

OFF

 

and

 

datalogging

 

ON:

 

approx.

 

25mAdc

 

 

With

 

backlight

 

ON

 

add

 

approx.

 

10mAdc

 

Weight

 

265g

 

(0.59

 

lbs.)

 

Dimensions

 

190

 

x

 

68

 

x

 

45mm

 

(7.5

 

x

 

2.7

 

x

 

1.8”)

 

 

 

 

 

Содержание SDL730

Страница 1: ...User Manual Heavy Duty Differential Pressure Manometer Model SDL730 Additional User Manual Translations available at www extech com ...

Страница 2: ...User Guide and Customer Support Safety International Safety Symbols This symbol adjacent to another symbol or terminal indicates the user must refer to the manual for further information Meter Description 1 P1 Input positive 2 P2 Input negative 3 LCD Display 4 HOLD and Backlight key 5 MAX MIN key 6 SET and Clock key 7 RS232 output jack 8 Reset button 9 Power Adaptor jack 10 SD card slot 11 ENTER a...

Страница 3: ...er is disabled Units of Measure The currently selected unit of measure is shown below the measurement value on the meter s LCD To change the unit of measure press and hold the UNIT button until the desired unit of measure appears and then release the UNIT button The meter begins scrolling through the available units of measure see table below after the UNIT button has been depressed for at least 1...

Страница 4: ...ormation is provided below this list dAtE Set the clock Year Month Date Hours Minutes Seconds SP t Set the datalogger sampling rate Hours Minutes Seconds PoFF Automatic power off management Enable or disable the auto power off function bEEP Set the beeper sound ON OFF dEC Set the numerical format USA decimal 20 00 or European comma 20 00 SdF Format the SD memory card Setting the Clock Time 1 Acces...

Страница 5: ...ait 7 seconds for the meter to automatically switch to the normal operating mode Numerical Format comma or decimal European and USA numerical formats differ The meter defaults to USA mode where a decimal point is used to separate units from tenths i e 20 00 The European format uses a comma i e 20 00 to separate units from tenths To change this setting 1 Access the dEC parameter 2 Use the arrow but...

Страница 6: ...dings encountered since the REC icon was switched on when the MAX MIN button was first pressed 5 To exit the MAX MIN mode press and hold the MAX MIN button for at least 1 5 seconds The meter will beep the REC MAX MIN icons will switch off the MAX MIN memory will clear and the meter will return to the normal operating mode Fittings Connection Connect tubing to the P1 P2 or both input port s If both...

Страница 7: ... change the sampling rate refer to the Setup Mode section the sampling rate cannot be 0 for automatic datalogging 1 Select the sampling rate in the Setup Mode to a value other than zero 2 Press and hold the LOG button for at least 1 5 seconds The meter will flash the DATALOGGER icon at the selected sampling rate indicating that readings are now being automatically recorded to the SD card 3 If a ca...

Страница 8: ...d 3 Plug the SD Card directly into a PC SD card reader If the PC does not have an SD card slot use an SD card adaptor available at most outlets where computer accessories are sold 4 Power the PC and run a spreadsheet software program Open the saved documents in the spreadsheet software program see example spreadsheet data screen below Spreadsheet data example AC Power Adaptor This meter is normall...

Страница 9: ...9 SDL730 en GB_V1 0 12 16 Hose Couplings This meter is supplied with a pair of hose couplings They fit 4 0mm 0 157 tubing See diagram on how to connect these couplings to the hose and the meter ...

Страница 10: ...orrect polarity Replace the battery compartment cover with the two 2 Phillips screws Never dispose of used batteries or rechargeable batteries in household waste As consumers users are legally required to take used batteries to appropriate collection sites the retail store where the batteries were purchased or wherever batteries are sold Disposal Do not dispose of this instrument in household wast...

Страница 11: ...in 59 sec Data lose may occur when logging at a 1 second rate MANUAL LOGGING Set the sampling rate to 0 seconds Select 1 to 99 locations Data error number 0 1 number of total saved data Memory Card SD memory card 1G to 16GB size Data Hold Freeze the displayed reading Memory Recall Record and Recall the Maximum and Minimum readings Display update rate Approx 1 second Operating Temperature 0 to 50 C...

Страница 12: ... 1 700 0 kPa 0 5 7000 hPA 5 2810 inches H2O 2 71 35 m H2O 0 05 6 905 ATP 0 005 Conversions Useful conversion Factors From To Multiplier in of H2O in of Hg 0 07355 in of H2O cm of H2O 2 54 mm of Hg in of H2O 0 53524 Copyright 2016 FLIR Systems Inc All rights reserved including the right of reproduction in whole or in part in any form ISO 9001 Certified www extech com ...

Отзывы: