background image

RHT10 HW_SW-en-US_V5.6.2   6/16 

7

 

The

 

LED

 

Flash

 

Cycle

 

can

 

be

 

set

 

by

 

the

 

user:

  

longer

 

cycle

 

times

 

help

 

to

 

extend

 

the

 

battery

 

life.

 

 

The

 

ALARM

 

SETTINGS

 

area

 

of

 

the

 

SETUP

 

window

 

allows

 

the

 

user

 

to

 

set

 

high

 

and

 

low

 

temperature

 

and

 

humidity

 

limits

 

and

 

to

 

disable

 

the

 

flashing

 

of

 

the

 

RHT10’s

 

LEDs,

 

thereby

 

conserving

 

battery

 

energy.

 

 

Once

 

the

 

changes

 

have

 

been

 

made,

 

click

 

on

 

the

 

SETUP

 

button

 

to

 

save

 

them.

  

Press

 

the

 

DEFAULT

 

button

 

to

 

set

 

the

 

RHT10

 

back

 

to

 

factory

 

default

 

conditions.

 

Press

 

the

 

CANCEL

 

button

 

to

 

abort

 

the

 

setup.

 

 

Note:

 

Any

 

stored

 

data

 

will

 

be

 

permanently

 

erased

 

when

 

the

 

user

 

clicks

 

on

 

Setup.

  

To

 

save

 

the

 

data

 

before

 

creating

 

a

 

new

 

setup,

 

click

 

Cancel

 

and

 

then

 

download

 

the

 

data.

 

 

Note:

 

The

 

battery

 

may

 

run

 

out

 

before

 

the

 

RHT10

 

has

 

finished

 

collecting

 

a

 

specified

 

number

 

of

 

sample

 

points.

  

Always

 

ensure

 

that

 

the

 

remaining

 

charge

 

in

 

the

 

battery

 

is

 

sufficient

 

to

 

last

 

the

 

complete

 

duration

 

of

 

your

 

logging

 

exercise.

  

When

 

in

 

doubt,

 

we

 

recommend

 

that

 

you

 

always

 

install

 

a

 

fresh

 

battery

 

before

 

logging

 

critical

 

data.

 

 

 

If

 

INSTANT

 

was

 

selected

 

in

 

the

 

SETUP

 

window,

 

the

 

RHT10

 

begins

 

logging

 

at

 

the

 

instant

 

the

 

SETUP

 

button

 

is

 

pressed.

  

If

 

MANUAL

 

was

 

selected,

 

the

 

RHT10

 

must

 

be

 

manually

 

started

 

by

 

pressing

 

and

 

holding

 

the

 

device’s

 

yellow

 

button

 

for

 

approx.

 

3

 

seconds,

 

or

 

until

 

the

 

two

 

LEDs

 

on

 

the

 

RHT10

 

flash

 

at

 

the

 

same

 

time.

 

 

Logging

 

will

 

continue

 

at

 

the

 

programmed

 

sample

 

rate

 

until

 

the

 

number

 

of

 

readings

 

(sample

 

points)

 

specified

 

in

 

the

 

Setup

 

window

 

is

 

reached.

 

 

The

 

green

 

LED

 

flashes

 

once

 

per

 

sample

 

point

 

and

 

the

 

red

 

or

 

yellow

 

LED

 

flashes

 

when

 

user

 

programmed

 

alarm

 

limits

 

are

 

exceeded.

 

For

 

details,

 

see

 

LED

 

status

 

guide.

 

 

 
 
 
 
 
 
 
 
 
 

www.

.com

[email protected]

1.800.561.8187

Содержание RTH10

Страница 1: ...USER GUIDE Humidity Temperature Datalogger Model RHT10 www com information itm com 1 800 561 8187 ...

Страница 2: ... The data logger is supplied with a long life lithium battery which can typically allow logging for one year This meter is shipped fully tested and calibrated and with proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates and Customer Support Features Memory for 32 000 readings 16 000 temperature...

Страница 3: ...S_V5 6 2 6 16 3 Description 1 Protective cover 2 USB connector to PC port 3 Start button 4 RH and Temperature sensors 5 Alarm LED red yellow 6 Record LED green 7 Mounting clip www com information itm com 1 800 561 8187 ...

Страница 4: ...ion program does not automatically open and provide on screen prompts open and browse the CD ROM drive then find and double click on the SETUP EXE file included on the program disk Follow the on screen prompts to complete the installation Software Install Run SETUP up exe and follow the defaults to install he RTH10 software USB Driver Install 1 Open the root folder of the RHT10 2 Open the folder D...

Страница 5: ...ick the Datalogger Graph icon on your desktop to launch the program The opening screen will appear as shown below Click on Connect to open the main screen Click on About to view the version number Click on View File to open an existing file Click on Quit to close the program www com information itm com 1 800 561 8187 ...

Страница 6: ... pull down menu The Setup window will appear as shown below descriptions for each field in the Setup window are listed directly below the illustration The CURRENT TIME field will automatically synchronize with the PC date and time setting The MANUAL and INSTANT select buttons allow the user to start data logging immediately when the Setup window is exited INSTANT or at a later time MANUAL The LOGG...

Страница 7: ...10 has finished collecting a specified number of sample points Always ensure that the remaining charge in the battery is sufficient to last the complete duration of your logging exercise When in doubt we recommend that you always install a fresh battery before logging critical data If INSTANT was selected in the SETUP window the RHT10 begins logging at the instant the SETUP button is pressed If MA...

Страница 8: ...n transferring readings If the readings are successfully transferred the VIEW screen and the SAVE screen both shown below will appear In the SAVE screen name the file and save it to a convenient location The data is saved as an rec file for use in this program only At a later time the user can select SAVE AS and save the data as an Excel Text or Bitmap file explained in next section In the screen ...

Страница 9: ...1 Use the mouse to click and drag a box around any data area to magnify the selected area 2 Click on the zoom magnifier icon tool on the menu bar 3 Select VIEW ALL or ZOOM OUT from the VIEW pull down menu In the example graph above the Temperature is represented by the solid red line the lines are known as traces the RH and Dew Point are represented by the solid yellow and green lines respectively...

Страница 10: ...r select SAVE AS from the FILE pull down menu The data can be saved in the following formats TEXT FILE txt EXCEL FILE xls BITMAP FILE bmp To open an existing data file for viewing on the data graph window click on the FILE OPEN icon on the menu bar 3rd from left or select FILE OPEN from the FILE pull down menu When prompted select a rec file saved earlier FILE PRINT To print a data graph window to...

Страница 11: ...stributor using the part number RHT10 SW Note that the standard RHT10 software must be un installed before the optional RHT10 SW software can be installed To view GPP data click on the VIEW menu heading and scroll down to the SHOW TRACES tab Ensure that the GPP line is checked If checked the graph will display GPP data If unchecked the graph will not show GPP data www com information itm com 1 800...

Страница 12: ...ta will be lost Replace battery Record Alarm Yellow single flash every 10 sec Logging low alarm for TEMP Yellow double flash every 10 sec Logging high alarm for TEMP Yellow single flash every 60 sec RHT10 memory full Download data To save power the RHT10 s LED flashing cycle can be changed to 20s or 30s via the supplied software To save power alarm LEDs for temperature can be disabled via the supp...

Страница 13: ...1 8o F Dew Point Temperature Overall Range 40 to 158o F 40 to 70o C Accuracy 25o C 40 to 100 RH 4 0o F 2o C Grains per pound 1120 gpp 160g kg max Available only with optional RHT10 SW software Logging rate Selectable sampling interval From 2 seconds up to 24 hours Operating temperature 31 to 176o F 35 to 80o C Battery type 3 6V Lithium 1 2 AA SAFT LS14250 Tadiran TL 5101 or equivalent Battery life...

Страница 14: ...6V lithium batteries Before replacing the battery remove the datalogger from the PC Follow diagrammatic steps 1 through 4 below NOTE Leaving the RHT10 plugged into the PC USB port longer than necessary will cause some of the battery capacity to be lost WARNING Handle lithium batteries carefully observe warnings on battery casing Dispose of in accordance with local regulations Safety Please dispose...

Страница 15: ...ication FLIR Systems Inc specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct indirect incidental or consequential damages FLIR s total liability is limited to repair or replacement of the product The warranty set forth above is inclusive and no other warranty whether written or oral is expressed or implied Calibra...

Отзывы: