manualshive.com logo in svg
background image

User Manual 

 
 

 

Refrigerant Leak Detector 

 

Model RD200 

 

 

 

 

Additional User Manual Translations available at www.extech.com 

Содержание RD200

Страница 1: ...User Manual Refrigerant Leak Detector Model RD200 Additional User Manual Translations available at www extech com ...

Страница 2: ...e sensitivity levels Battery status LED indicator Test solution included allows the user to check the condition of the sensor 50 cm 19 7 flexible gooseneck probe Safety Please read the safety information carefully before attempting to operate the meter Failure to do so could cause personal injury or damage to the meter Please read this manual carefully to ensure safe and correct use Do not attempt...

Страница 3: ...ch ON or if the low battery LED 4 glows red 2 While powering on the leak level LEDs 2 will light in sequence left to right and the start up tone will sound once 3 The meter will start heating the sensor 7 during a 2 minute warm up period the leak level LEDs will continue to light in sequence during the warm up 4 After the warm up the audible tone will sound twice indicating that the detector is re...

Страница 4: ...The distance of the sensor 7 to the surface of the component under test should be 5mm 0 2 or nearer Move the probe slowly no more than 25 50mm second 1 to 2 second See the Measurement Considerations section for more information Note To pinpoint a large leak more effectively use compressed air on the suspected area of the leak to help determine the precise location Testing for Leaks in an Evaporato...

Страница 5: ...equipment Checking the Probe Condition with the Test Solution The test bottle provided contains an ethanol solution that emits a gas when the bottle is opened If the sensor is in good condition it will detect the gas and the meter will provide audible and visual alerts If alerts do not occur the sensor should be replaced immediately Always tightly seal and safely store the test bottle when not in ...

Страница 6: ... 2 minutes approx Response Time Instantaneous Auto Power OFF Automatic shut off after 10 minutes Low Battery Indication Battery status LED glows red Power Supply 9V Battery rear compartment under protective jacket Battery Life 30 hours of normal use Operating Conditions 0 C to 50 C 32 F to 122 F 80 RH Storage Conditions 10 C to 80 C 14 F to 176 F 70 RH Length Flexible Gooseneck only 50 2cm 19 8 Le...

Отзывы: