background image

 MO260-en-GB_V1.5   8/16 

6

LCD Backlight ON/OFF 

With the meter switched ON, pressing and holding both front panel buttons (MODE and HOLD) 
switches the LCD backlight ON and OFF. 

Data Hold feature 

The Data Hold function freezes the reading in the display. Press the

 HOLD

 key momentarily to 

activate the Data Hold function. The reading will freeze and the ‘key’ display icon will appear. Press 
the 

HOLD

 key again to exit the Data Hold function (the ‘key’ display icon will switch off).  

 

Meter Setup 

 

 

To enter the setup mode: 
With the meter switched OFF, press and hold both front panel buttons (MODE and HOLD 
buttons) simultaneously for two seconds. The display should now read ‘0 = x’ where ‘0’ is the 
OPTION and ‘x’ is the SETTING. 

 

Use the MODE (right arrow) button to change the SETTING. 

 

Use the HOLD button to scroll through the OPTIONS. 

 

The available OPTIONS and SETTINGS: 

  

OPTIONS 

SETTINGS 

SET-UP INFORMATION 

Switches all settings to ‘0’ (Factory Default*) 

Others settings can now be changed. In addition, Backlight 
switches ON for 30 seconds and then automatically switches 
OFF. 

Audible alert beeps with increasing frequency from a nominal 
17.0 (REL) or 17% (WME) measurement value upwards 

Audible alert divided into 3 frequency levels 

Audible alert beeps when user switches from one mode to 
another 

Beeper OFF. Audio alert display symbol switches OFF 

Auto Switch OFF is not active. User must manually switch the 
unit OFF 

Auto Switch OFF active. Switches OFF after 3 minutes 

Auto Switch OFF active. Switches OFF after 5 minutes 

Auto Switch OFF active. Switches OFF after 10 minutes 

Backlight OFF 

Backlight ON 

*FACTORY DEFAULT SETTINGS: 0=0, 1=0, 2=0, 3=0 

Содержание MO260

Страница 1: ...USER MANUAL Dual Moisture Meter Pin Pinless Moisture Meter Model MO260...

Страница 2: ...ble service Features WME wood moisture equivalent pin moisture reading Relative REL pinless moisture reading for non invasive measurement Digital LCD readout with backlighting feature and tri color LE...

Страница 3: ...th the protective cap Calibration points located at the top of protective cap LCD Display Description 1 Measurement reading 2 Battery status 3 Audible alert icon 4 Measurement mode 5 Display HOLD icon...

Страница 4: ...ly if it is pushed towards the rear of the meter The cap can be affixed to the side of the meter using the protective cap holders 6 2 Press the key to turn the meter ON OFF 3 Press the MODE key to sel...

Страница 5: ...EL mode 2 Ensure that the meter is not near any objects or surfaces Hold the meter near the bottom to avoid contact with the pinless sensor 3 Press and Hold the MODE button for 3 seconds until rEL app...

Страница 6: ...ht arrow button to change the SETTING Use the HOLD button to scroll through the OPTIONS The available OPTIONS and SETTINGS OPTIONS SETTINGS SET UP INFORMATION 0 0 Switches all settings to 0 Factory De...

Страница 7: ...never use abrasives or solvents Prevent dirt from accumulating at the electrode pins How a Pinless Moisture Meter Measures Moisture A pinless meter is a relative or unit less measurement device Unlike...

Страница 8: ...4 8 WME pins Electrode pin length 11mm 0 44 Electrode pin type Integrated replaceable Power supply 9V alkaline battery Low Battery Indication Battery symbol displayed on LCD Meter housing Impact proof...