Display Description 

 

Relative mode icon 

 

Units of Frequency 

AC 

Alternating Current 

 

Units of Voltage 

DC 

Direct Current 

 

Units of Capacitance 

 

Negative readings 

NCV 

Non-contact  AC  Voltage 
Detect 

 

Diode mode 

 

Automatic range mode 

 

Continuity mode 

 

Low Battery icon 

 

Display Hold 

 

Duty Cycle 

 

Units of resistance 

 

Measurement overload 

Control Buttons 

  

 

Mode button: Short press to step through the mode options for the selected 
measurement function 

  

 

HOLD button: Short press to freeze/unfreeze reading 

  

 

Backlight button: Short press to turn backlight ON or OFF. Note that the backlight 
button is on the upper right side of the meter. 

  

 

For AC/DC voltage, AC current and Resistance modes: Short press to store the 
displayed reading as a reference value. Subsequent measurements will be displayed 
as ‘measurement minus reference value’. Short press to exit.  
For Capacitance mode, short press to zero the display; the LCD will show the delta 
symbol. Short press to exit this mode. 

  

 

Short press to step through frequency (Hz) and duty cycle (%) measurements for the 
Voltage and Hz switch positions.  

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание MA610

Страница 1: ...USER MANUAL 600A AC Clamp Meter NCV Model MA610 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...finger guards at all times Remove test leads from the meter before opening the battery compartment or meter housing Use the meter only as specified in this User Manual or accompanying Quick Start to a...

Страница 3: ...the test points before changing the position of the function rotary switch Do not expose the meter to extremes in temperature or to high humidity Never set the meter to the resistance diode capacitan...

Страница 4: ...ment in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation OVERVOLTAGE CATEGORY IV E...

Страница 5: ...ort press to freeze unfreeze reading Backlight button Short press to turn backlight ON or OFF Note that the backlight button is on the upper right side of the meter For AC DC voltage AC current and Re...

Страница 6: ...o power ON 2 Move the function switch to the OFF position to remove power to the meter 3 The meter has an Auto Power OFF feature APO where the meter switches OFF after 30 minutes of inactivity Press a...

Страница 7: ...are of an unknown range 2 The A and the AC symbols will appear on the display indicating AC Amperes Amps 3 Press the jaw trigger to open the clamp jaw 4 Position the clamp around only one conductor Se...

Страница 8: ...der test 5 Read the voltage in the LCD The display will indicate the proper decimal point and value 6 Relative REL mode can be used to set a reference reading from which subsequent readings will be of...

Страница 9: ...probe tips across the circuit or part under test It is best to disconnect one side of the part under test so that the rest of the circuit will not interfere with the resistance reading 5 Read the res...

Страница 10: ...tion switch to the Continuity position 2 Use the M mode button to select the continuity display icon 3 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana...

Страница 11: ...black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the red jack See Fig 6 2 Touch the test probe tips across the circuit or component 3 Read the Frequenc...

Страница 12: ...red test lead banana plug into the red jack See Fig 7 4 Touch the test probe tips across the circuit or component 5 Read the Capacitance measurement on the meter display For readings 400 F several min...

Страница 13: ...lack test lead banana plug into the negative COM jack and the red test lead banana plug into the red V jack See Fig 8 4 Touch the test probes to the diode under test in both polarity directions one at...

Страница 14: ...eld is at highest levels the meter s NCV lamp and beeper rate will become one continuous light and tone If the meter does not react as described above to an AC voltage there is still the possibility t...

Страница 15: ...Safety Please dispose of batteries responsibly never dispose of batteries in a fire batteries may explode or leak never mix battery types install new batteries of the same type Fig 10 BATTERY REPLACEM...

Страница 16: ...5 digits 600V AC DC 40 00V 0 01V 400 0V 0 1V 600V 1V 1 5 5 digits DC Voltage 400 0mV 0 1mV 1 0 8 digits 600V AC DC 4 000V 0 001V 0 8 1 digit 40 00V 0 01V 0 8 3 digits 400 0V 0 1V 600V 1V 1 0 3 digits...

Страница 17: ...nsitivity 10Hz 1MHz 200mVrms input amplitude 20Vrms Duty Cycle 0 1 99 9 0 1 2 5 600V AC DC Input amplitude 500mVrms Input amplitude 20Vrms Duty Cycle applies to 10kHz Square Wave Specified accuracy ra...

Страница 18: ...magnetic field disturbance in the measurement environment Maximum Voltage 600V AC DC maximum applied to any terminal Low battery indication is displayed Auto Power OFF After 30 minutes Operating Tempe...

Отзывы: