Introduction 

Thank  you  for  selecting  the  Extech  MA610  Clamp  Meter.  This  meter  measures  AC  Current, 
AC/DC Voltage, Resistance, Capacitance, Frequency, Diode Test, Duty Cycle, Continuity and Non-
Contact  Voltage  detection.  This  device  is  shipped  fully  tested  and  calibrated  and,  with  proper 
use, will provide years of reliable service.

Features 

 

Large backlit LED display 

 

30mm (1.2") jaw size fits conductors up to 500MCM 

 

Relative and Zero mode functionality 

 

Auto Power OFF (APO) 

 

Non-Contact Voltage Detector 

 

Visual and audible continuity measurement alert 

 

Low battery indicator  

 

CAT III 600V 

Safety 

To ensure the safe operation and service of the meter, follow these instructions closely. Failure to 
observe warnings can result in severe injury. 

WARNINGS 

WARNINGS identify hazardous conditions and actions that could cause BODILY HARM or DEATH. 

 

When handling test leads or probes, keep hands and fingers behind the finger guards at all times. 

 

Remove test leads from the meter before opening the battery compartment or meter housing. 

 

Use the meter only as specified in this User Manual or accompanying Quick Start to avoid compromising 
the protections provided by the meter. 

 

Be sure to use the proper terminals, switch positions, and ranges when taking measurements. 

 

Verify the meter’s operation by measuring a known voltage. Have the meter serviced if the meter 
responds unusually or if there are questions regarding the meter’s functional integrity. 

 

Do not apply more than the rated voltage, as marked on the meter, between terminals or between any 
terminal and earth ground. 

 

Use caution working with voltages above 30 VAC RMS, 42 VAC peak, or 60 VDC. These voltages pose a 
shock hazard. 

 

To avoid misleading readings that could lead to electric shock and injury, replace the batteries as soon as 
the low battery indicator is displayed. 

 

Disconnect power to the circuit under test and discharge all high-voltage capacitors before testing 
resistance, continuity, diodes, or capacitance. 

www.

GlobalTestSupply

.com

Find Quality Products Online at:

[email protected]

Содержание MA610

Страница 1: ...USER MANUAL 600A AC Clamp Meter NCV Model MA610 www GlobalTestSupply com Find Quality Products Online at sales GlobalTestSupply com...

Страница 2: ...finger guards at all times Remove test leads from the meter before opening the battery compartment or meter housing Use the meter only as specified in this User Manual or accompanying Quick Start to a...

Страница 3: ...the test points before changing the position of the function rotary switch Do not expose the meter to extremes in temperature or to high humidity Never set the meter to the resistance diode capacitan...

Страница 4: ...ment in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use with permanent connection to the fixed installation OVERVOLTAGE CATEGORY IV E...

Страница 5: ...ort press to freeze unfreeze reading Backlight button Short press to turn backlight ON or OFF Note that the backlight button is on the upper right side of the meter For AC DC voltage AC current and Re...

Страница 6: ...o power ON 2 Move the function switch to the OFF position to remove power to the meter 3 The meter has an Auto Power OFF feature APO where the meter switches OFF after 30 minutes of inactivity Press a...

Страница 7: ...are of an unknown range 2 The A and the AC symbols will appear on the display indicating AC Amperes Amps 3 Press the jaw trigger to open the clamp jaw 4 Position the clamp around only one conductor Se...

Страница 8: ...der test 5 Read the voltage in the LCD The display will indicate the proper decimal point and value 6 Relative REL mode can be used to set a reference reading from which subsequent readings will be of...

Страница 9: ...probe tips across the circuit or part under test It is best to disconnect one side of the part under test so that the rest of the circuit will not interfere with the resistance reading 5 Read the res...

Страница 10: ...tion switch to the Continuity position 2 Use the M mode button to select the continuity display icon 3 Insert the black test lead banana plug into the negative COM jack Insert the red test lead banana...

Страница 11: ...black test lead banana plug into the negative COM jack Insert the red test lead banana plug into the red jack See Fig 6 2 Touch the test probe tips across the circuit or component 3 Read the Frequenc...

Страница 12: ...red test lead banana plug into the red jack See Fig 7 4 Touch the test probe tips across the circuit or component 5 Read the Capacitance measurement on the meter display For readings 400 F several min...

Страница 13: ...lack test lead banana plug into the negative COM jack and the red test lead banana plug into the red V jack See Fig 8 4 Touch the test probes to the diode under test in both polarity directions one at...

Страница 14: ...eld is at highest levels the meter s NCV lamp and beeper rate will become one continuous light and tone If the meter does not react as described above to an AC voltage there is still the possibility t...

Страница 15: ...Safety Please dispose of batteries responsibly never dispose of batteries in a fire batteries may explode or leak never mix battery types install new batteries of the same type Fig 10 BATTERY REPLACEM...

Страница 16: ...5 digits 600V AC DC 40 00V 0 01V 400 0V 0 1V 600V 1V 1 5 5 digits DC Voltage 400 0mV 0 1mV 1 0 8 digits 600V AC DC 4 000V 0 001V 0 8 1 digit 40 00V 0 01V 0 8 3 digits 400 0V 0 1V 600V 1V 1 0 3 digits...

Страница 17: ...nsitivity 10Hz 1MHz 200mVrms input amplitude 20Vrms Duty Cycle 0 1 99 9 0 1 2 5 600V AC DC Input amplitude 500mVrms Input amplitude 20Vrms Duty Cycle applies to 10kHz Square Wave Specified accuracy ra...

Страница 18: ...magnetic field disturbance in the measurement environment Maximum Voltage 600V AC DC maximum applied to any terminal Low battery indication is displayed Auto Power OFF After 30 minutes Operating Tempe...

Отзывы: