MA44x

en

GB_V1.0

   

8/16

 

7

Operation

 

CAUTIONS

 

 

Read

 

and

 

understand

 

all

 

of

 

the

 

Safety

 

statements

 

listed

 

in

 

the

 

safety

 

section

 

of

 

this

 

manual

 

prior

 

to

 

use.

 

Powering

 

the

 

Meter

 

1.

 

Move

 

the

 

function

 

switch

 

to

 

any

 

position

 

to

 

power

 

the

 

meter.

 

Check

 

the

 

batteries

 

if

 

the

 

unit

 

fails

 

to

 

power

 

ON.

 

2.

 

Move

 

the

 

function

 

switch

 

to

 

the

 

OFF

 

position

 

to

 

remove

 

power

 

to

 

the

 

meter.

 

3.

 

The

 

meter

 

has

 

an

 

Auto

 

Power

 

OFF

 

feature

 

(APO)

 

where

 

the

 

meter

 

switches

 

OFF

 

after

 

30

 

minutes

 

(MA440)

 

or

 

15

 

minutes

 

(MA443/MA445)

 

of

 

inactivity.

 

The

 

MA443/MA445

 

models

 

emit

 

a

 

warning

 

tone

 

prior

 

to

 

automatically

 

switching

 

off.

 

Disable

 

Auto

 

Power

 

OFF

 

(MA443

 

and

 

MA445)

 

To

 

defeat

 

the

 

APO

 

feature:

 

1.

 

With

 

the

 

meter

 

OFF,

 

press

 

and

 

hold

 

the

 

M

 

(MODE)

 

button

 

and,

 

while

 

continuing

 

to

 

hold

 

the

 

M

 

button,

 

turn

 

the

 

rotary

 

switch

 

to

 

any

 

position.

 

2.

 

The

 

meter

 

will

 

beep

 

five

 

times

 

indicating

 

that

 

APO

 

has

 

been

 

deactivated.

 

3.

 

The

 

Auto

 

Power

 

OFF

 

function

 

will

 

now

 

be

 

disabled

 

until

 

the

 

next

 

cycle

 

of

 

power.

 

4.

 

When

 

APO

 

is

 

active,

 

the

 

APO

 

symbol

 

 

is

 

displayed.

 

When

 

APO

 

is

 

not

 

active,

 

the

 

APO

 

symbol

 

is

 

not

 

displayed.

   

 

 

Содержание MA440

Страница 1: ...USER MANUAL Model MA440 400A AC Clamp Meter DMM Model MA443 True RMS 400 AC Clamp Meter DMM Model MA445 True RMS 400A AC DC Clamp Meter DMM...

Страница 2: ...ed and calibrated and with proper use will provide years of reliable service Please visit our website www extech com to check for the latest version of this User Guide Product Updates Product Registra...

Страница 3: ...60 days 9 Do not service or modify the internal circuits of the meter Qualified personnel must service the meter only 10 Do not use the meter in flammable or explosive environments gas or vapors Do n...

Страница 4: ...e or high humidity Safety Symbols This symbol adjacent to another symbol indicates the user must refer to the manual for further information Risk of electrical shock Alert beeper Equipment protected b...

Страница 5: ...ht button MA443 and MA445 11 NCV sensor Note Battery compartment is located on back of meter Fig 1 Meter Description Display Description Relative mode icon Units of Frequency Alternating Direct Curren...

Страница 6: ...ent measurements will be displayed as measurement minus reference value This feature applies to AC DC voltage AC current resistance and temperature modes only Short press to exit For DC current measur...

Страница 7: ...r switches OFF after 30 minutes MA440 or 15 minutes MA443 MA445 of inactivity The MA443 MA445 models emit a warning tone prior to automatically switching off Disable Auto Power OFF MA443 and MA445 To...

Страница 8: ...ing AC Amperes Amps The display icon AUTO will also appear indicating automatic ranging 3 Press the jaw trigger to open the clamp jaw 4 Position the clamp around only one conductor See Fig 2 for corre...

Страница 9: ...3 and Fig 4 4 Press the jaw trigger to open the clamp jaw Position the clamp around only one conductor See Fig 2 previous section for correct and incorrect clamping techniques 5 Read the current in t...

Страница 10: ...oint and value 6 Relative REL mode can be used to set a reference reading from which subsequent readings will be offset reference reading actual reading displayed reading Long press the REL button to...

Страница 11: ...test probe tips across the circuit or part under test It is best to disconnect one side of the part under test so that the rest of the circuit will not interfere with the resistance reading 5 Read th...

Страница 12: ...k See Fig 7 above 4 Touch the test probe tips across the circuit or wire 5 If the resistance is 30 the meter will beep If the resistance is 60 the meter will not beep If the resistance is between 30 a...

Страница 13: ...ive COM jack Insert the red test lead banana plug into the positive jack See Fig 9 4 Touch the test probe tips across the circuit or component 5 Read the Capacitance measurement on the meter display F...

Страница 14: ...nsert the black test lead banana plug into the negative COM jack and the red test lead banana plug into the positive V jack See Fig 10 4 Touch the test probes to the diode under test in both polarity...

Страница 15: ...ocouple Do not measure temperature if the meter is in an environment outside the range of 18 28o C Do not input voltages 30V DC or AC to the meter 1 Turn the function switch to the TEMP position 2 Use...

Страница 16: ...g When the sensed field is at highest levels the meter s NCV lamp and beeper rate will become as one continuous light and tone If the meter does not react as described above to an AC voltage or electr...

Страница 17: ...rtment 3 Replace the three 3 1 5V AAA batteries observing correct polarity 4 Re assemble the meter before use 5 Safety Please dispose of batteries responsibly never dispose of batteries in a fire batt...

Страница 18: ...range Frequency response 50 60Hz MA440 and MA443 and 40 400Hz MA445 MA443 MA445 AC Crest factor considerations a Add 4 MA443 3 MA445 when wave factor is 1 2 b Add 6 MA443 5 MA445 when wave factor is 2...

Страница 19: ...A440 50 00nF 0 01 nF 4 0 25 digits 600V AC DC 500 0nF 0 1 nF 4 0 5 digits 5 000 F 0 001 F 50 00 F 0 01 F 100 0 F 0 1 F Capacitance MA443 and MA445 40 00nF 0 01 nF 4 0 25 digits 600V AC DC 400 0nF 0 1...

Страница 20: ...0 400 o C 400 1000 o C 1 0 3 digits 40 104 o F 1o F 3 0 10 digits 104 752 o F 752 1832 o F 1 0 6 digits Does not include accuracy of the Type K temperature probe Non Contact Voltage Detector NCV 100Vr...

Страница 21: ...mum applied to any terminal Low battery indication is displayed Auto Power OFF After 30 minutes MA440 or 15 minutes MA443 and MA445 Hold M button while turning meter ON to disable APO MA443 and MA445...

Отзывы: