Specifications 

General Specifications 

Display 

2000 count Digit LCD with white LED backlight 

Polarity 

Minus sign (-) indicates negative polarity 

Jaw opening 

18mm (0.7”) 

Current sensor 

Hall effect sensor type 

AC Current Bandwidth 

50/60Hz 

AC Voltage Bandwidth 

50/400Hz 

Overload indication 

“OL” displayed on the LCD 

Display rate 

2 readings/second, nominal 

Battery 

Two 1.5V AAA batteries 

Low Battery indication 

“BATT” displayed on the LCD 

Auto Power off 

approx. 15 minutes 

Operating conditions 

0 to 30

º

C (32 to 86

º

F) 90%RH; 30 to 40

º

C (86 to 104

º

F) 75%RH; 40 to 

50

º

C (104 to 122

º

F) 45%RH 

Storage conditions 

-30 to 60

º

C (-14 to 140

º

F); < 90% Relative Humidity 

Altitude 

Operate at less than 3000 meters 

Weight 

176g (6.2 oz.) including battery 

Dimensions 

164 x 65 x 32mm (6.5 x 2.6 x 1.3”) (HWD) 

Standards 

For indoor use and in accordance with the requirements for double 
insulation to IEC1010-1 (1995): EN61010-1 (1995) Overvoltage Category 
III 300V and Category II 600V, Pollution Degree 2. 

CC

Содержание MA150-T

Страница 1: ...USER MANUAL Model MA150 200A AC Mini Clamp on Meter Additional User Manual Translations available at www extech com...

Страница 2: ...p trigger 8 MODE key 9 COM input jack 10 V input jack 9 10 Safety Information Caution Refer to the explanation in this Manual Double Insulation This meter has been designed to be safe in use but the o...

Страница 3: ...2 Set the function switch to the position 3 Use the MODE button to select resistance The M icon will appear in the display 4 Touch the test leads across the circuit or component under test It is best...

Страница 4: ...st reading on the LCD short press the MAX key The meter reading will not change as readings change rather it will only display the highest reading encountered since the MAX hold button was pressed Pre...

Страница 5: ...AA batteries Low Battery indication BATT displayed on the LCD Auto Power off approx 15 minutes Operating conditions 0 to 30 C 32 to 86 F 90 RH 30 to 40 C 86 to 104 F 75 RH 40 to 50 C 104 to 122 F 45 R...

Страница 6: ...0 1V 600V 1V 1 5 rdg 3 digits AC Voltage 2 000V 1mV 1 5 rdg 3 digits 20 00V 10mV 200 0V 0 1V 600V 1V 2 0 rdg 4 digits Resistance 200 0 0 1 1 0 rdg 4 digits 2 000k 1 1 5 rdg 2 digits 20 00k 10 200 0k 1...

Страница 7: ...responsibly never dispose of batteries in a fire batteries may explode or leak If the meter is not to be used for 60 days or more remove the battery and store separately Never dispose of used batterie...

Отзывы: