background image

MA130-en-GB_V1.0   10/16 

 

Do not use the meter in the presence of explosive gas 
or vapor. 

 

To reduce risk of fire or electric shock, do not use the 
meter if it is wet and do not expose the meter to 
moisture. 

 

Individual protective equipment should be used if 
HAZARDOUS LIVE parts in the installation where 
measurements are to be carried out could be 
accessible. 

CAUTIONS 

CAUTIONS identify conditions and actions that 
could cause 

DAMAGE to the meter or equipment under test. Do 
not expose the meter to extremes in temperature 
or high humidity. 

 

Do not expose the meter to extremes in temperature 
or to high humidity. 

Safety Symbols that are typically marked 
on meters and instructions 

 

This symbol, adjacent to another 
symbol, indicates the user must refer 
to the manual or user guide for 
further information. 

 

Risk of electrical shock 

 

Equipment protected by double or 
reinforced insulation 

 

Battery symbol 

 

Conforms to EU directives 

 

Do not discard this product in 
household trash 

 

AC measurement 

 

Earth ground 

Содержание MA130

Страница 1: ...USER MANUAL 200A AC Mini Clamp Meter Model MA130 Please visit www extech com for user manual translations...

Страница 2: ...w battery indicator and Auto Power Off feature CAT II 600V and CAT III 300V safety rating Safety Information To ensure the safe operation and service of the meter follow these instructions closely Fai...

Страница 3: ...d actions that could cause DAMAGE to the meter or equipment under test Do not expose the meter to extremes in temperature or high humidity Do not expose the meter to extremes in temperature or to high...

Страница 4: ...nces OVERVOLTAGE CATEGORY III Equipment of OVERVOLTAGE CATEGORY III is equipment in fixed installations Note Examples include switches in the fixed installation and some equipment for industrial use w...

Страница 5: ...d in the safety section of this manual prior to use Powering the Meter 1 Turn the rotary function switch to any position to power the meter Check the batteries if the unit fails to power ON Refer to t...

Страница 6: ...s geometric center as possible 5 Do not allow a gap between the two halves of the jaw 6 Read the ACA value on the LCD Data Hold To freeze the displayed reading on the LCD long press the Data Hold H bu...

Страница 7: ...esponsibly never dispose of batteries in a fire batteries may explode or leak If the meter is not to be used for 60 days or more remove the battery and store separately Never dispose of used batteries...

Страница 8: ...d Battery Two 1 5V AAA batteries Low battery display Operating Temperature 0 C to 40 C 32 F to 104 F Operating Humidity 0 C to 30 C 32 F to 86 F 75 RH 30 C to 40 C 86 F to 104 F 50 RH Storage Temperat...

Страница 9: ...00 A 10mA 3 0 rdg 20 digits 200A AC 200 0 A 100mA 2 5 rdg 20 digits 200A AC Notes Frequency range 50 60Hz Maximum overload protection for clamp head terminal is 200A Accuracy stated for 10 100 of ran...