Model IRC350    Version 4.0    06/08 

Introduction 

Congratulations on your purchase of the Extech IRC350 Infrared Calibrator. This easy to 
use portable calibrator can be used to accurately calibrate Infrared (IR) thermometer 
devices. This instrument is shipped fully tested and calibrated and, with proper use, will 
provide years of reliable and accurate calibration of temperature sensors and devices. 
 

Features 

 

2.3” (58mm) diameter target assembly and dry-well temperature system controlled 

by microcomputer 

 

Metal cone external reference thermometer with nominal heat-conducting ability 

 

Oxide film, surface thermometer with an Emissivity of 0.95.  

 

Class-A, platinum 100 ohm (PT100) RTD temperature sensor 

 

R

apid heating and cooling (fan) functions

 

 

°C /°F selectable units 

 

Calibration temperature range

 

of 122°F to 662°F (50°C to 350°C)

 

0.1° temperature display and stability resolution 

 

 

Warranty 

EXTECH INSTRUMENTS CORPORATION (A FLIR COMPANY) warrants this instrument 
to be free of defects in parts and workmanship for one (1) year from date of shipment (a 
six month limited warranty applies to sensors and cables). If it should become necessary to 
return the instrument for service during or beyond the warranty period, contact the 
Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our 
website www.extech.com for contact information. A Return Authorization (RA) number 
must be issued before any product is returned to Extech. The sender is responsible for 
shipping charges, freight, insurance and proper packaging to prevent damage in transit. 
This warranty does not apply to defects resulting from action of the user such as misuse, 
improper wiring, operation outside of specification, improper maintenance or repair, or 
unauthorized modification. Extech specifically disclaims any implied warranties or 
merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, 
incidental or consequential damages. Extech's total liability is limited to repair or 
replacement of the product. The warranty set forth above is inclusive and no other 
warranty, whether written or oral, is expressed or implied. 

 

 

Содержание IRC350

Страница 1: ...User Guide Infrared Calibrator Model IRC350 ...

Страница 2: ...efects in parts and workmanship for one 1 year from date of shipment a six month limited warranty applies to sensors and cables If it should become necessary to return the instrument for service during or beyond the warranty period contact the Customer Service Department at 781 890 7440 ext 210 for authorization or visit our website www extech com for contact information A Return Authorization RA ...

Страница 3: ...nded when in use This instrument is intended for indoor use only DO NOT use this instrument for any applications other than those described in this User Guide Cautions Components and heater lifetime can be shortened by continuous high temperature operation DO NOT use liquids to clean the target surface DO NOT adjust the values of the calibration constants from the factory set values The correct se...

Страница 4: ...ting Time 30 minutes to maximum temperature Cooling Time 30 minutes from maximum to 212 F 100 C Aperture Diameter 2 3 58mm Power 115VAC 10 3A Operating Ranges Temperature 41 to 95 F 5 to 35 C Relative Humidity 15 to 80 Altitude Less than 2 000 Meters Aperture Diameter 2 3 58mm Size 7 1 x 4 5 x 9 2 180 x 114 x 233 mm Weight 6 6 lbs 3 kg Temperature differences between the IR surface and the referen...

Страница 5: ...ault 9ºF 4 5ºC The fan will increase to maximum velocity when the alarm limit is reached ALM2 Unused C Unit of measure temperature indicator Celsius F Unit of measure temperature indicator Fahrenheit 4 Controller Keypad For setting the desired temperature set point and for selecting the unit of measure SET Used to enter into the programming mode enter the temperature set points or to store the ºF ...

Страница 6: ...alibrator has two speeds and runs continuously when the unit is being operated to provide cooling for the instrument The fan runs slow for heating and maintaining operation and runs fast for rapid cooling Slots are provided for airflow The area around the calibrator must be kept clear to allow adequate ventilation The airflow is directed out the front and can be extremely hot ...

Страница 7: ...adjusting the set point value do not adjust factory only programming parameters If a factory menu is inadvertently accessed press the SET button to return to the main display screen The IRC 350 can display temperature in degrees Celsius C or Fahrenheit F To change the display units 1 Unlock the unit by pressing and holding the SET and buttons at the same time 2 When the display changes release bot...

Страница 8: ...d well temperature gradually changes until it reaches the set point temperature The well may require 5 to 10 minutes to reach the set point Another 5 to 10 minutes is required to stabilize within the stated limits of the set point Ultimate stability may take an additional 15 to 20 minutes 4 Reduce the temperature to a value below 212 F 100 C before turning the instrument off Warning Turning off th...

Отзывы: